Electrical Engineer Services in  Augusta Maine

Structural Engineering Near Me

Everyone from American Samoa to South Carolina, know that for affordable MEP engineering service in Augusta Maine – MEP.NY-Engineers.Com is the top option. What quite a few local architects do not know is that we is also the ideal partners for anyone looking for Electrical Engineering Service in Augusta Maine. Just so that you know that NY-Engineers.Com if a full-service national engineering firm offering Electrical Engineering Services, Plumbing Engineering Services, Sprinkler Engineering Services, Fire Protection Engineering Services, Construction Administration Engineering Services, Value Engineering Services, Energy Modeling Engineering Services, Utility Filings Engineering Services, Engineering Reports Services, Building Commissioning Engineering Services, CAD to Revit Modeling Engineering Services, MEP Engineer, Mechanical Engineering, Electrical Engineering, Plumbing Engineering, Sprinkler Engineering, Fire Protection Engineering, Construction Administration, Value Engineering, Energy Modeling, Utility Filings, Engineering Reports, Building Commissioning, CAD to Revit Modeling, Mechanical Engineering Services, and more. In regards to our Electrical Engineering Service near Augusta Maine. As a full-service company we can help project with just about anything you can bring to us. With that said, out most requested projects include but are not limited to Electrical Lighting Designs, Mechanical Power Designs, Electrical Riser Diagrams, Panel Board Schedules, New Building Electrical Design, Renovation Electrical Design, Preparation of Electric Load Letters, Emergency Generator Systems, Sub-Metering or Direct Metering, Switchgear, Main or Sub Distribution Panel, and Branch Wiring Design.

Precisely what do electrical engineers do? If you’re thinking of hiring an electrical engineer for a job, you’re going to need to ensure that you choose somebody who comes strongly suggested, and should want to look for somebody that is fully qualified. In addition to all of that , you would like to learn a little bit more about what an electric engineer actually does. This is how uncover more concerning this profession.

Speak To People Who Have Hired Engineers Previously – One of the best ways to learn what it would be like to work alongside an electrical engineer is to talk to some of your colleagues which may have hired one in the past. Whether they had the engineer develop a power system for these people or hired these people to test their existing equipment, you’ll have the capacity to learn quite a bit from the experiences.

Interview Some Candidates – Not every engineer has the same set of skills. Prior to hiring anyone, you’ll desire to spend time interviewing your top choices. Throughout this interview, you’ll have the opportunity to go over their past assist them. You will discover when they have relevant expertise.

Pay Attention To Your Project – Before deciding if you must hire one of those engineers, you need to look at the project that you will be hiring them for. Look at the work you will need these people to do. Spend some time to consider what an engineer could do for you personally, and explore some of your other choices also.

Electrical engineers are equipped for a myriad of electrical work. You need to take a closer look at what these professionals do to enable you to see if they could possibly aid you with your preferences. You can benefit greatly if you hire a seasoned engineer to assist you. As you can see we are not just a local Electrical Engineer in or near Augusta Maine. We can help you with everything from MEP Engineer, Mechanical Engineering, Electrical Engineering, Plumbing Engineering, Sprinkler Engineering, Fire Protection Engineering, Construction Administration, Value Engineering, Energy Modeling, Utility Filings, Engineering Reports, Building Commissioning, CAD to Revit Modeling, Mechanical Engineering Services, Electrical Engineering Services, Plumbing Engineering Services, Sprinkler Engineering Services, to Fire Protection Engineering Services, Construction Administration Engineering Services, Value Engineering Services, Energy Modeling Engineering Services, Utility Filings Engineering Services, Engineering Reports Services, Building Commissioning Engineering Services, CAD to Revit Modeling Engineering Services and more. For more information on everything we do at NY Engineers take a look at our Utility Filings blog.

Popular Post Related to Electrical Engineer Services in Augusta Maine

Basic Concepts of Lighting Design, According to Electrical Engineers

How To Become A Fire Protection Engineer

Lighting system design is a very important aspect of construction projects, and the best performance is achieved when lighting is specified through detailed calculations and not “rules of thumb” by electrical engineers. However, lighting has a key difference with other building systems like HVAC and plumbing: there is a subjective and artistic factor involved. Lighting systems must provide adequate visibility, but they also set the ambiance of built environments.

Effective communication is important in any engineering design process, and this is only possible if the parties involved are familiarized with key technical concepts. This article will provide an overview of the main terms used when specifying lighting systems.

The Lumen: Basic Unit of Luminous Flux

Just like electric current is measured in amperes and water flow is measured in gallons per minute, the lighting output of a lamp or fixture is measured in lumens. Watts are often used to describe the brightness of lamps, but this is an incorrect practice that leads to confusion:

  • A few decades ago when all light bulbs were incandescent, wattage could be used to describe brightness because there was a direct relationship between lumens provided and watts consumed.
  • However, this leads to confusion when comparing different types of lighting. For example, the lumen output is roughly the same for a 60W incandescent bulb, a 15W compact fluorescent light, and a 9W LED bulb.

A common misconception about LED lighting is that you end up with a darker room due to the reduced wattage. However, this comes from the old practice of describing brightness with watts, when the correct unit is the lumen.

The concept of luminous efficacy describes how efficiently a lamp converts watts of electricity into lumens, similar to the gas mileage (MPG) of a car. Just like a car with a higher MPG value has a lower fuel cost for a given distance travelled, a light source with a higher lm/W value has a lower electricity cost for a given lighting output. Upgrading to LED lighting is one of the most cost-effective energy efficiency measures for a building.

Lumens are useful when describing the output of a lamp or fixture, but a different measurement unit is required to describe the lighting needed by a specific area. For example, 10,000 lumens is more than enough lighting for a small office, but the effect is barely noticeable in a large warehouse. When describing the required lighting in built environments, the concept of illuminance is used.

Illuminance: Lumens per Unit of Area

The concept of illuminance is used to describe the lighting required for a given occupancy, regardless of size. There are two common measurement units:

  • Lux, or lumens per square meter.
  • Footcandle (fc), or lumens per square foot.
  • 1 fc = 10.7639 lux

Since illuminance is specified per unit of area, room size does not matter. For example, an illuminance of 50 fc has the same meaning for a 500 sq. ft. office and for a 2500 sq. ft. office, with the difference that more lighting fixtures are required for the larger office. Illuminance values are specified by the Illuminating Engineering Society of North America (IESNA) in their Lighting Handbook.

In actual lighting design, the illuminance level varies due to the spacing of fixtures and their beam shapes. However, slight variations are acceptable as long as no areas are too dark or too bright. Illuminance is determined not only by the lighting distribution, but also by room features such as ceiling height and surface colors – manual calculations are very complex, but the process is automated with software in modern lighting design. Electrical engineers know how to create lighting designs that are ideal for a space, thus preventing wildly varying illuminance levels.

Photometry: What is the Beam Shape of Lamps and Fixtures?

Light beam shape is another important aspect considered by lighting designers. For example, spotlights concentrate their output into a narrow beam facing downwards, while troffers in offices spread their output over the largest possible area to achieve uniform lighting.

Do not assume that two light bulbs can be used for the same application just because their bases have the same shape. Using a light source with the wrong beam shape yields poor results even if the lumen output is calculated correctly.

The beam shape of a lamp or fixture is three-dimensional, and product models used in lighting design software include this information for simulation purposes. On the other hand, a 3D beam shape cannot be represented in technical specifications; the beam is described with overlapping 2D figures that represent beam shape parallel and perpendicular to the light source.

Correlated Color Temperature and Color Rendering Index

Describing the color performance of lighting requires two separate metrics, one for the light source and another for the objects it illuminates.

  • The correlated color temperature (CCT) describes the color of the light source itself. When dealing with the CCT, no value is considered “the best”, since each lighting hue has different applications.
  • The color rendering index (CRI) describes how faithfully the light source renders the colors of objects and surfaces in the room. The maximum CRI value is 100, describing a light source that matches the quality of natural light – a higher CRI is always better regardless of the application.

How Electrical Engineers Use Temperature Values To Describe Lighting Color

Objects glow in a characteristic color depending on their temperature, and this is why lava from a volcano looks red. The same principle applies to stars, where a yellow star like the Sun is hotter than a red star, and a blue star is hotter than a yellow one. In physics, this behavior is described by an abstract concept called a “black body”, which is an object that emits no light except when heated, and each temperature corresponds with a specific color glow.

Light sources are not heated to the temperature implied by their CCT value, but it is a convenient way to assign a numerical value to their color. In most residential and commercial applications, the CCT value of lighting ranges from 2700K (yellowish white) to 6500K (bluish white). In other words, if a light product has a CCT of 4000K, it means it glows with the same color as a “black body” at 4000K, but the light source itself does not reach that temperature!

Although personal preference plays a role in CCT selection, the following principles apply to most lighting designs:

  • Low color temperatures like 2700K are perceived as “warm” and they tend to have a relaxing effect. They are preferred in areas like residential bedrooms, hotel rooms and high-end restaurants. Warm colors are not well suited for commercial and industrial settings, where the relaxing effect can be counterproductive.
  • High color temperatures like 6500K are perceived as “cool” and they tend to have an energizing effect, enhancing. They are preferred in applications where maximum visibility is required, such as high-precision manufacturing. Cool colors may delay sleep when used in residential and hospitality settings, and extended exposure may be described as “stressful” by some individuals.
  • CCT values around 4000K are perceived as “neutral” and they offer a balance point between the two extremes described above. Neutral white is the lighting color of choice for offices, classrooms, kitchens and similar locations where concentration is required for extended periods.

Effect of the Light Source on Objects and Surfaces

Even if two light sources have the same CCT value, their lighting quality may differ. A CRI value of 100 means the light source is a good as sunlight.

  • Despite their inefficiency, incandescent and halogen bulbs offer a CRI of 100.
  • Fluorescent bulbs tend to have the lowest color rendering performance, and low-tier products can go below 70.
  • CRI values for LED bulbs can vary significantly depeding on product quality. Low-end products go below 70, while high-performance products reach values close to 100.

The minimum CRI for a light bulb to get the ENERGY STAR label is 80. Therefore, looking for the label is an effective strategy to avoid lamps with poor color performance, and you can also rest assured that the product has passed rigorous laboratory tests. When dealing with LED bulbs, a higher CRI typically comes with a higher price tag, but there are applications where the CRI metric is very important – consider retail and art galleries, for example.

Conclusion

LED upgrades have the potential to reduce lighting power consumption by over 50 percent. If the space is air-conditioned, indirect savings are achieved by reducing the heat footprint of lamps and fixtures. It can be tempting to simply swap the existing lighting with the most efficient product available, but lighting design must not be overlooked, say electrical engineers – lighting savings should not be achieved at the expense of quality.

M2e Engineering

Electrical Engineer Service Augusta Maine

Electrical Engineer Services in  Augusta Maine From Massachusetts to Nevada construction companies have come to rely on us when they need fast MEP Engineers near Augusta Maine. With that said, it is important to note that we are more than that! We're eight national engineering company offering not only design but also consulting services. Even though we are focused on mechanical, electrical and plumbing (MEP) installations. NY-Engineers.Com offers a wide range of [...]

2019-02-26T16:43:27+00:00

MEP Engineer Service in Augusta Maine

MEP Engineer Service Augusta Maine The great majority of architectural firms in South Dakota know that New York Engineers is the go to company if you are looking for CAD to Revit Modeling. However, primarily because of the company's constant expansion many individuals have failed to realize that NY Engineers is perhaps top partner when you're searching for MEP Engineer in or near Augusta Maine. MEP is short for mechanical, electrical, and [...]

2019-01-26T03:25:37+00:00