Fire Sprinkler System Engineering in Clarendon Park Chicago

Contact Us!

Searching for a top rated Fire Sprinkler Plumbing Design Experts in or near Clarendon Park Chicago Illinois? Your best bet is to contact is NY Engineers. Not only for Fire Protection Company but also Mechanical Engineering and HVAC Firms in Chicago. Contact us at (+1) (312) 767-6877

Contact Us!
Value Engineering Techniques

If you ask any general contractor or developer anywhere from Cragin Chicago to South Edgebrook Chicago, and have them refer you a professional MEP Engineering in Chicago, and the answer you will likely get is go to NY Engineers. What’s not commonly known is that New York Engineers also your best bet for anyone looking for a fire protection engineer in Clarendon Park Chicago. The reality is there is no shortage of HVAC engineering or protection engineering companies in Clarendon Park Chicago. However, when it comes to reliability is always best to choose a company like New York Engineers.

Should you be able to plan the construction of a building, one of the first professionals that you should consult with is called a fire protection engineer. These are individuals who are well aware of design safeguards and risks that should be well-thought-out. They could help with the design of any building, ensuring that you will have the capability to control, plus stop, fires that might be catastrophic. They often deal with developers, architects, and building owners that are responsible for the building of a fresh home or building. Many reason exist for getting a fire protection engineer that you ought to consider.

Why you should hire one of those experts – There are 2 main reasons for getting a fire protection engineer. To begin with, you must guarantee the safety of everyone that can eventually be present at that structure frequently. Finally, you should have many possible safeguards in place should a fire starts. Anything that they suggest is going to be respected by developers, and afterwards incorporated into the particular building. If getting a fire protection engineer is the next step of your project, it is possible to find a number of them that will help you out.

Just What Is The Concept Of Fire Protection Engineer in Clarendon Park Chicago?

The concept of fire protection engineer is simply the study of fire with regards to our built-up environment and how architectural design sways the causes and spread of fire. Still, this task of engineering has to do with utilizing engineering principles (mechanical, chemical, electrical, and civil engineering), physics, material science, chemistry, technology to implement underlying fire subdual system that safeguards both humans and also the property under consideration.

In this connection, fire protection engineering is really a study and field that is associated with saving lives and property from disaster way before fire emerges. Fire protection engineers use their skill to impact just how the fire suppression system in the building happens. To the end, they will have a say in the design of a building, the types of materials used in the building of the building, along with the building layout. Essentially, a fire protection engineer could have input with regards to fire detection and suppression method used.

Their efforts ensure that whenever a fire starts, the suppression system operates to control the fire effectively, allowing time for anybody in the building to escape to safety. Furthermore, the suppression system that is choosen should stop the spread of fire, negating the opportunity of the fire spreading even more. There is a great possibility you would like additional info about fire sprinkler engineer services in Clarendon Park Chicago by NY Engineers you should take a look at our Chicago Value Engineering blog.

Engineering Reports Related Blog Article

Construction Engineers Present Tips from the Passive House Institute US

Structural Engineering Near Me

The Passive House Institute US (PHIUS) is an organization that promotes passive building standards and best practices for construction engineers and others. They also offer certification programs for buildings and products, as well as professional certifications for architects and engineers. This article will provide an overview of some their main guidelines for passive house construction. It is important to note that, although the word “house” is used, these concepts apply for high-rise multifamily buildings and commercial facilities as well.

The PHIUS summarizes its building philosophy as “maximize your gains, minimize your losses”, focusing on achieving synergy between energy efficiency and comfort. The five main principles to consider for passive building are the following:

  1. High-performance insulation
  2. Airtight building envelope
  3. High-performance windows
  4. Using heat and moisture recovery to minimize HVAC expenses
  5. Managing solar heat gain, promoting it during the winter and reducing it during the summer

According to PHIUS, a passive building is around 5% to 10% more expensive than a conventional one, but this is compensated many times during the building lifetime through energy savings. In addition, passive buildings are more comfortable, since they eliminate two main issues affecting conventional buildings: air drafts and temperature fluctuation. In commercial settings, comfort can also lead to increase profits, by stimulating employees to be more productive.

1)   High-Performance Insulation

The main benefit of high-performance insulation is that space heating and cooling loads are reduced. As a result, HVAC systems can be sized smaller, compared with a building that uses the minimum insulation required by construction codes. A smaller HVAC system can be installed with less capital and also has a lower operating cost.

The PHIUS emphasizes the importance of avoiding thermal bridges, which are concentrated spots in the building envelope where insulation is deficient compared with the surroundings. Heat transfer tends to concentrate in thermal bridges, causing unwanted heat gain in the summer and heat loss in the winter.

Current building codes are limited when addressing thermal bridges, since their specifications are based on U-values for insulation and one-dimensional modeling of thermal envelopes. Thermal bridges are a complex three-dimensional phenomenon that can be addressed more effectively with the building modeling software utilized by knowledgeable construction engineers.

2) Airtightness

Air leaks can be just as detrimental as poor insulation when it comes to building envelope performance. Any air exchange between conditioned and unconditioned spaces causes heating and cooling equipment to work harder. Air leakage tends to be more common around windows, doors, plumbing fixtures and electrical fixtures.

In existing constructions, air leakage can be addressed effectively with caulking and weatherstripping. Both have the same purpose, which is blocking spaces where air leakage occurs. The main difference is that caulking is designed for fixed elements like plumbing and electrical fixtures, while weatherstripping is designed to tolerate friction in moving elements like doors and windows. However, caulking should be used for the external edges of door and window frames, which are not subject to relative motion. In new constructions, airtightness can be built into the envelope during the project construction phase.

3) High-Performance Windows

Significant heat transfer occurs through windows, even when the surrounding walls are well insulated. High-performance windows are one of those energy efficiency upgrades that can be deployed in existing constructions, but which is much more cost-effective in new buildings.

  • In an existing building, the upgrade cost is the full price of the window plus the associated labor cost.
  • In new constructions, there is a baseline window and labor cost that is unavoidable, and only the price premium of a high-performance window is considered for financial analysis.

The most energy-efficient windows in the market currently use a triple pane, inert gas to fill the two resulting spaces, a fiberglass frame and low-emissivity coating for the glass. Double pane windows apply the same concept, giving up on part of the energy efficiency to achieve a lower price. However, both triple-pane and double-pane windows are much more efficient than conventional models with single uncoated sheets of glass and metallic frames. A double-pane window is around 50% more efficient than a conventional one, while a triple-pane window provides an efficiency boost of 20-30% compared with a double-pane one.

4) Heat and Moisture Recovery

Since HVAC systems have the goal of controlling temperature and humidity, a higher efficiency can be achieved if the exhaust air is used to precondition the intake air. Heat-recovery ventilation (HRV) only exchanges heat between the supply and exhaust airstreams, while energy-recovery ventilation (ERV) exchanges heat and moisture. The operating principle is reversed for summer and winter conditions:

  • Outdoor air tends to be warmer and more humid during the summer. Therefore, the exhaust air can be used to remove some of its heat and moisture. This reduces the HVAC load and improves energy efficiency.
  • Outdoor air is cool and dry during the winter, so the exhaust air can be used to preheat and humidify it before reaching the HVAC system. This also achieves a load reduction.

5) Solar Heat Gain Optimization

Managing solar heat gain can be tricky. It is beneficial during the winter since it reduces the load on space heating systems; however, during the summer it increases cooling load and must, therefore, be minimized. Also, solar glare should be avoided regardless of the time of the year – it causes discomfort and distraction while having the potential to damage human vision.

Window shades are a simple and effective measure to control solar heat gain. The sun is higher in the sky during the summer, and shades block a larger portion of its radiation. The sun’s altitude drops as winter approaches, and more radiation enters the building, reducing space heating loads. In some locations in the northern hemisphere, is important to note that south-facing windows get the most sunshine throughout the year, and north-facing windows get the least. East-facing windows receive plenty of sunshine during the morning and west-facing windows during the afternoon. Windows should be arranged so that the sun itself is not in direct line-of-sight for occupants. Greater control is possible with optimal building orientation, window shades, and well-placed vegetation.

Construction Engineers Make These Final Recommendations

Developers interested in a passive building can achieve the best results by working with certified design professionals. For example, the Passive House Institute US has the Certified Passive House Consultant (CPHC) program. There are more than 1,300 CPHCs in the USA, and they have been extensively trained in energy modeling software and passive building while considering the variety of climate zones in the USA. The US Green Building Council also offers the LEED certification for construction engineers and other professionals, where many topics covered deal with energy-efficient construction.

Common searches related to Sprinkler Engineer in Clarendon Park Chicago

Mechanical Engineering Salary

Fire Protection Engineering Clarendon Park Chicago

Fire Sprinkler Engineering in Clarendon Park Chicago If you're looking for a competent Fire Protection Contractor near Clarendon Park Chicago Illinois? The one to go to is NY Engineers. Not only for Fire Sprinkler Systems Design Services but also Construction Engineering and HVAC Firms in Chicago. Contact us at (312) 767.6877 As of late when you approach any general contractor or developer form Central Station to Near East Side, about a [...]

2018-11-10T12:28:59+00:00