Fire Sprinkler System Engineer in Oak Park Chicago

Contact Us

Searching for Fire Sprinkler Systems Design Services in or near Oak Park Chicago Illinois? Your best bet is to call is NY-Engineers.Com. Not only for Fire Protection Company but also Mechanical Engineering and HVAC Chicago. Call us at 312 767.6877

Contact Us
Is There A Demand For Mechanical Engineers In The Future

Ask any contractor or building owner form K Town to Little Italy Chicago, and have them refer you a reliable HVAC Engineering in Chicago, and the majority will say contact NY-Engineers.Com. What’s not commonly known is that NY-Engineers.Com also your best option for anyone looking for a fire sprinkler system engineering in Oak Park Chicago. The reality is there is no shortage of mechanical engineering or sprinkler engineering companies in Oak Park Chicago. However, when it comes to affordability is always best to choose a from like New York Engineers.

In case you are ready to plan the making of a building, among the first professionals you should talk to is a fire protection engineer. They are people who are knowledgeable about design protections and threats that ought to be well-thought-out. They might aid in the look of any structure, making sure that you will have the opportunity to control, plus prevent, fires that might be catastrophic. They generally assist architects, building owners, and developers that are responsible for the making of a brand new home or building. Many reason exist for working with a fire protection engineer that you ought to consider.

Why you need to hire one of those pros – Here are the two main reasons for hiring a fire protection engineer. To start with, you should ensure that the care of everybody that can sooner or later enter that edifice consistently. Finally, you should have several possible safeguards set up just in case a fire starts. Precisely what they mention will likely be considered by contractors, and subsequently included in the specific structure. If getting a fire protection engineer is the next stage of your project, you can actually find a number of them which can help you out.

Just What Is The Meaning Of Fire Protection Engineer in Oak Park Chicago?

The concept of fire protection engineer is simply the study of fire in terms of our built-up environment and the way architectural design sways the reasons and spread of fire. Furthermore, this discipline of engineering has to do with making use of engineering principles (mechanical, chemical, electrical, and civil engineering), chemistry, physics, material science, technology to execute underlying fire suppression system that protects both humans and also the property in question.

In this regard, fire protection engineering is a field and study that is certainly involved in saving lives and property from fire way before fire emerges. Fire protection engineers apply their knowledge and experience to influence the way the fire suppression system in the building happens. For this end, they may have input in the look of a building, the types of materials utilized in the construction of the property, along with the building layout. Essentially, a fire protection engineer will have input in relation to fire detection and suppression method used.

Their efforts make sure that when a fire starts, the suppression system works to suppress the fire effectively, allowing time for any individual in the building to get out to safety. Furthermore, the suppression system that is choosen should stop the spread of fire, negating the chance of the fire spreading a lot more. Even with all of this information you would like additional info on fire sprinkler engineer services in Oak Park Chicago by NY-Engineers.Com we invite you to visit at our blog.

New Plumbing Engineering Related Post

Simplify Your MEP Engineering Design: Put an End to Over-Engineering

Mechanical Engineering Salary

The “more is better” mindset does not always apply in MEP engineering projects. Over-engineered components often increase project costs without providing any real benefits, and there are many cases where excessive capacity in fact has negative consequences on performance and service life. Another type of over-engineering occurs when the system used for a specific application is too complex, and a much simpler solution would have been possible without compromising performance.

General Disadvantages of Over-Engineering

Regardless of the specific application, over-engineering drives up project costs without offering significant benefits: oversized components are more expensive, and the associated labor cost also increases because equipment becomes more difficult to handle.

When mechanical, electrical and plumbing systems are too complex for the application at hand, there is also a higher chance of error during construction, due to the introduction of unnecessary components. This increases the chance of MEP engineering professionals and others involved in the project having to deal with change orders during project construction.

Over-engineering also brings performance issues that are specific to each type of building system. HVAC installations tend to suffer the most: an over-engineered system can be just as problematic as an undersized one, if not more.

Oversized Electrical Circuits

The main issue with oversized electrical circuits is their high cost. In fact, performance is improved: oversized conductors reduce both heat dissipation and voltage drops. The problem is that these benefits are not enough to justify the drastic increase in costs:

  • Copper is expensive.When you consider that a typical building has thousands of feet of electric circuits, the cost of oversized conductors adds up very quickly
  • Conduit diameter is increased.Electric codes establish a maximum fill percentage for conduit, so increased conductor capacity also involves larger conduit and accessories.
  • Labor costs are increased.Since they are more difficult to handle, larger conduit and circuits typically require more man-hours of work. In most cases, specialized tools may also be needed.

When the extra costs of oversized conductors are considered, they far outweigh the benefits. Oversized conductors are particularly common with energy-efficient HVAC equipment – they are often specified based on “rules of thumb” that only apply for older and less efficient equipment.

The NEC and other electric codes may establish a maximum allowable voltage drop. It varies depending on the application, but in most cases either 3% or 5% is used. In these cases, conductor diameter should be raised so that voltage drop is brought to acceptable levels, but any further increases are unnecessary.

Using various supply voltages in the same installation is an excellent way to optimize conductor diameters. Keep in mind that power transmitted is proportional to both voltage and current, but only current defines conductor diameter. If a piece of electrical equipment draws too much current at 240 V, it makes sense to increase rated voltage to 480 V – this reduces line current, allowing smaller conductors to be specified. Of course, these are design choices that can only be determined by qualified professionals.

Oversized Electric Motors

In the case of electric motors, over-engineering tends to bring far more issues than with conductors. When subject to part-load conditions, electric motors display two main types of negative behavior:

  • They suffer a drastic reduction in efficiency when the mechanical load on their shaft is much lower than their rated load. For example, a motor loaded at 80% does not suffer an efficiency drop, but for values under 50% the effect becomes significant.
  • Power factor is also reduced when a motor is loaded lightly. Utility companies normally establish a minimum power factor for their consumers, and there are extra power bill charges for falling below that value.

Of course, another drawback of oversized electric motors is the drastic price increase. Motors can be among the most expensive pieces of electrical equipment, and oversizing them only reduces efficiency and power factor.

When specifying electric motors, special consideration must be given the voltage rating, since it determines the characteristics of all circuits and breakers located upstream. Large motors may justify the use of voltages such as 480V or 600V to prevent excessively high currents.

Air-Conditioning Systems

There are many types of air-conditioning systems, including mini-split units, packaged terminal air conditioners (PTAC), packaged rooftop units (RTU) and heat pumps. However, over-engineering tends to bring a common set of performance issues:

  • Oversized compressors run in shorter and more frequent cycles, which is detrimental for their components and results in increased maintenance expenses. Keep in mind that compressor motors draw an inrush current that is several times their rated value each time they start – ideally, they should not cycle more than necessary.
  • Air conditioning systems have the goal of controlling both temperature and humidity, but many types are cycled on and off based on temperature alone. Since oversized units reach the temperature set point faster, they are unable to extract enough humidity and the resulting environment is cool but humid. This is uncomfortable for occupants, and may bring health issues as well.

Compressors are not the only AC system components that bring performance issues when oversized. In system configurations that use air ducts, over-engineering also brings several negative consequences. For example, oversized ducts involve displacing a large volume of air, which drives up the CFM and power requirements of blowers.

In chiller plants and other types of AC installations that use hydronic piping, the extra cost associated with over-engineering can be particularly high. Other than being expensive, oversized piping requires more pumping power, increasing the nameplate capacity of both pumps and motors.

For air conditioning installations that will be subject to gradual capacity increases, variable refrigerant flow (VRF) systems can be a great choice – their modular nature offers great flexibility to size their capacity precisely depending on building needs. Chiller plants also offer flexibility, but are better suited for larger capacity increments than those typical of VRF systems.

Heating Systems

For heating systems that are based on heat pumps, the same logic of air conditioning installations applies: oversized compressors suffer from frequent cycling and normally experience a diminished service life.

In the case of oil and gas boilers, the main drawback of over-engineering comes from short cycling: a phenomenon that occurs when an oversized boiler meets heating demand too quickly and then shuts down. To better understand the impact of short cycling, consider that boilers operate in a four-step cycle: pre-purge, firing interval, post-purge and idle period. When the firing interval is short, several negative consequences arise:

  • The boiler radiates heat from its enclosure through the entire cycle, including the two purge phases and the idle period. Oversized boilers waste more energy in the form of radiated heat.
  • During the pre-purge and post-purge steps, fans are used to displace any flammable mixture of gases that may have been left in the boilers. Both purging stages consume energy.

Although gas and oil boilers can cycle depending on the load, doing so is very inefficient. A superior alternative is to use two or more boilers of reduced capacity, which offers the flexibility to meet varying load conditions with energy-efficient operation. If there is a large demand for heating at any given moment, for example on Monday mornings during the winter, all boilers can be used simultaneously. Then, some of the units can be shut down to avoid short cycling losses.

The misconception that a larger boiler is better dates to the time when fireplaces and chimneys were used for indoor heating: a larger chimney offered greater flexibility to accommodate fires of any size. However, modern boilers operate on completely different physical principles, and the assumption no longer holds.

Concluding Remarks from an MEP Engineering Professional

Over-engineering can be favorable in specific applications where a high safety factor is required, but in most cases, it only drives up MEP engineering project costs without a significant return on investment. In fact, oversized systems typically come with a higher cost of operation due to inefficient operation and frequent maintenance expenses. Hiring the services of a qualified design firm is the best way to ensure MEP installations are engineered properly.

Popular searches related to Sprinkler Design Engineer in Oak Park Chicago

Mechanical Engineering Career

Fire Protection Engineering Oak Park Chicago

Fire Protection Engineering in Oak Park Chicago If you re searching for a fast responding Fire Protection Engineer in Oak Park Chicago Illinois? Your best bet is to call is NY-Engineers.Com. Not only for Fire Sprinkler Systems Design Services but also Mechanical Engineering and HVAC Engineering in Chicago. Contact us at (312) 767-6877 Nowadays if you ask any general contractor or building management company form Clearing West to South Loop Chicago, [...]