Fire Sprinkler Engineer in Oakwood Hills

Contact Us

Searching for Commercial & Residential Fire Sprinkler Systems Design near Oakwood Hills Illinois? The one to go to is NY Engineers. Not only for Commercial & Residential Fire Sprinkler Systems Design but also Architectural Engineering and HVAC Firms near Chicago. Call (312) 767.6877

Contact Us
What Do Architectural Engineers Do

Ask any contracting company or developer anywhere from Chinatown Chicago to Ravenswood Manor Chicago, and have them refer you a professional HVAC Engineering in Chicago, and undesputed response will be call New York Engineers. What’s not commonly known is that NY-Engineers.Com also your best bet for anyone looking for a fire sprinkler system engineer in Oakwood Hills. The truth is there is no shortage of value engineering or sprinkler engineering companies in Oakwood Hills. However, when it comes to dependability is always best to choose a from like NY-Engineers.Com.

If you’re ready to plan the construction of a building, one of the first professionals that you should check with is a fire protection engineer. They are individuals that are knowledgeable about design protections and threats that must be studied. They may assist in the design of any structure, confirming that you will have the ability to control, plus prevent, fires that could be catastrophic. They often deal with building owners, architects, and developers that are responsible for the construction of a whole new building or home. There are several reasons for employing a fire protection engineer that you must consider.

Why you need to hire one of these brilliant experts – Here are the two premiere factors behind employing a fire protection engineer. To start with, you need to make sure the care of everyone which will sooner or later be at that house regularly. Also, it is very important to have as many possible possible safeties set up in case a fire happens. Exactly what they mention will likely be considered by investors, and afterwards incorporated into the exact building. If choosing a fire protection engineer is the next stage of your project, it is simple to find a number of them which will help you out.

What Is The Meaning Of Fire Protection Engineer in Oakwood Hills?

The meaning of fire protection engineer is just the study of fire in terms of our built-up environment and just how architectural design influences the causes and spread of fire. Moreover, this work of engineering has to do with working with engineering principles (mechanical, chemical, electrical, and civil engineering), physics, material science, chemistry, technology to execute underlying fire subdual system which protects both humans and also the property under consideration.

In this connection, fire protection engineering is actually a field and study that is linked to saving lives and property from disaster way before fire emerges. Fire protection engineers use their training to influence just how the fire suppression system in a building occurs. For this end, they will likely have input in the style of a building, the types of materials used in the construction of the property, and the building layout. Importantly, a fire protection engineer could have input in terms of fire discovery and suppression method used.

Their efforts make certain that every time a fire starts, the suppression system actively works to suppress the fire effectively, and give time for anyone in the building to escape to safety. Furthermore, the suppression system they choose should hinder the spread of fire, nullifying the possibility of the fire spreading more. There is only so much you can save this page if you would like additional details on fire sprinkler engineer services in Oakwood Hills by New York Engineers you should check out at our Chicago Fire Protection Engineering blog.

New Building Commissioning Related Blog Article

MEP Engineering Tips: 7 Ways to Minimize Mechanical Space

How To Become An HVAC Engineer

In any MEP engineering project, the Mechanical equipment carries out a fundamental role in residential, commercial, and industrial locations, performing functions such as:

  • Space cooling and heating
  • Supplying chilled or hot water
  • Refrigeration
  • Ventilation
  • Indoor humidity control

These types of equipment and their associated ductwork and piping are notorious for their high space requirements, but there are several ways to make mechanical installations more compact.

1)      Installing Boilers as Close to the Roof as Possible

Boilers that operate with the combustion of fuels such as oil, propane, natural gas, biomass, or biodiesel require a chimney to exhaust their flue gases. Since the chimney must cross the entire distance from the boiler to the rooftop, its space requirements are increased as the boiler is located farther from the uppermost level – there are more floors to go through.

Installing a boiler at the highest possible location in a building shortens the chimney, which offers three significant advantages:

  • The space that the chimney would have used on each floor is freed up for other purposes.
  • The installation becomes safer, because the risk of flue gases being released indoors is minimized.
  • The cost of the chimney is reduced.

An alternative to installing boilers on the attic or the uppermost floor of a building is to simply use a heating technology that does not require a chimney, such as an electric resistance heater or a heat pump. A solar water heater is also a viable option: it is located on the rooftop, saving indoor space, and it runs with sunlight, a free energy input.

2)      Installing Air Conditioning Units on Ceilings

The largest individual component of an air conditioning system is typically the condenser, which is normally located outdoors. When installed on the external walls of a home or building, condensers occupy plenty of space and may even represent an obstacle for outdoor circulation if located on the first floor.

Condensers also release a lot of heat, and the circulation of warm air may be restricted when outdoor spaces are reduced due to proximity with another building or a wall. This has two negative consequences that MEP engineering professionals must consider: warm air can make outdoor locations uncomfortable, and it reduces the operating efficiency of condensers. On the other hand, if a condenser is located on a rooftop, warm air can circulate more freely, and noise becomes less of an issue.

In large commercial or industrial facilities, the equipment used by air conditioning and cooling systems is much larger, but the same logic applies – installing these units on rooftops saves considerable outdoor space. However, this is only feasible if the structure is strong enough to support the weight. Examples of equipment that may be found outdoors in a typical commercial or industrial MEP engineering project settings include:

  • Packaged rooftop air conditioning units
  • Air-cooled chillers
  • Cooling towers for industrial processes or for water-cooled chiller plants

3)      Using the Same System for Cooling and Heating

A heat pump operates with the refrigeration cycle, the same physical principle on which air conditioners are based, with the difference that it operates in reverse – it extracts heat from the cooler outdoor environment and uses it for space or water heating. In addition, some heat pumps are reversible, which allows them to consolidate heating and cooling into a single piece of equipment.

Upgrading to a heat pump can also result in energy efficiency improvements. There are two key pieces of information to look for when comparing heat pump models:

  • The Seasonal Energy Efficiency Ratio (SEER) is the ratio of cooling output to energy input during the cooling season.
  • The Heating Seasonal Performance Factor (HSPF) is basically the same concept, but for when the heat pump is operating in heating mode.

The SEER and HSPF are ratios that relate BTUs (British Thermal Units) and watt-hours, and a higher value translates into reduced energy consumption: it means the unit needs less energy to meet a specific cooling or heating load. For example, an air conditioner with a SEER of 20 will only draw half the power of a SEER 10 unit, assuming both have the same cooling output.

Alternatively, unit efficiency may be reported as a Coefficient of Performance, which is also a ratio of cooling or heating output and power input, but using watts for all quantities. Heat pumps typically have a COP of 2.5 or more, which means they yield significant savings when replacing resistance heaters, whose COP is 1.

In MEP engineering, an ideal scenario for upgrading to a heat pump would be if a household uses a resistance heater and an old air conditioning unit. In this case, a heat pump would consolidate two devices into one, while improving energy efficiency in both modes of operation.

For industrial applications, using an absorption chiller is a viable option for consolidating heating and cooling systems. This type of chiller can use waste heat from a steam plant or an industrial process, and provide cold water for space and process cooling. It is important to note, however, that absorption chillers are viable only when there is sufficient waste heat; otherwise, a normal compression-based chiller is a better choice.

4)      Installing Mechanical Equipment in Normally Unused Spaces

Another viable strategy to minimize the useful indoor space on your next MEP engineering project that is typically taken up by mechanical equipment is to install these units in a location that is not normally used. One example of such locations is:

  • Roof Bulkheads – This is one type of structure that is found on many buildings and is rarely used. Their main purpose is providing access to the roof, and they tend to be used more during construction and maintenance than during actual building operation.

5)      Using Mini-Split Systems Instead of Packaged Rooftop Units for Small Buildings

Packaged rooftop units allow multiple condensers to be consolidated as a single unit, but they require considerable space for ductwork. In small residential and commercial locations, mini-split systems are often the superior choice, offering a simpler installation and superior energy efficiency. Packaged rooftop units normally go up to SEER 15, while mini-split systems are available with efficiency ratings of SEER 25 or above.

Mini-split systems are a practical choice in commercial locations that are split into several zones with independent schedules, such as open-air shopping malls. As locations become larger, rooftop packaged units emerge as the preferred choice – too many compressors and evaporators would be required to offer air conditioning with mini-split units.

6)      Vertically Aligning Equipment on Several Floors

Multi-story buildings normally have components that are repeated floor by floor, and mechanical equipment is no exception to this. For example, air conditioning systems in tall buildings often use a central chiller plant to cool water, which is then supplied to air handling units (AHU) that cool the air in each floor.

If AHUs and similar units are aligned vertically floor by floor, it is possible to distribute cold water to all of them with a single pipe running vertically across the building. Since ductwork is installed above the false ceiling, most mechanical equipment will be located out of sight.

The associated electrical installations providing power to mechanical equipment also become more compact when similar units are aligned vertically or horizontally. Multiple circuits can be installed within a single conduit run, and it is also possible to use a bus duct for equipment drawing high current.

7)      Hiring Qualified MEP Engineering Professionals for the Design Stage

A well-organized mechanical installation takes up less space, and making sure the layout is as simple as possible is a process that starts from the project design phase. If mechanical, electrical, and plumbing installations (MEP) are designed together, equipment and associated components can be specified and located with the following goals in mind:

  • Minimizing the space and materials requirements.
  • Avoiding clutter caused by components from different buildings systems.

There are now software packages that allow 3D MEP models to be created and visualized before starting the construction process — including Revit. These models are of great assistance when planning how mechanical installations will be laid out on your next MEP engineering project, and are also very useful for contractors during materials takeoff and construction.

Conclusion

Optimizing the space used by mechanical equipment in your MEP engineering projects offers several advantages beyond comfort. It may be possible to reduce the cost of installations, and in many cases it also increases energy efficiency. The best way to ensure a mechanical installation offers top performance and an optimal layout is to hire qualified designers and contractors for the project.

searches related to Sprinkler System Engineer in Oakwood Hills

Structural Engineering Near Me

Fire Protection Engineering Oakwood Hills

Fire Protection Engineer in Oakwood Hills If you re searching for a competent Fire Sprinkler Systems Design Services near Oakwood Hills Illinois? Your best bet is to reach out to is NY Engineers. Not only for Commercial & Residential Fire Sprinkler Systems Design but also Electrical Engineering and HVAC Firms in Chicago. Call us at (+1) (312) 767.6877 As of late if you ask any contracting company or developer form Calumet [...]

2018-11-22T02:46:28+00:00