Hiring a HVAC Engineering Contractor in Bowmanville Chicago

Construction Engineering Pdf

A great number of real estate investors throughout East Northport, New York already know that NY Engineers is the engineering company to contact when you’re searching for Architectural Engineering in New York City. What a lot local developers have yet to realized is that NY-Engineers.Com is also your best choice if you are looking for HVAC Engineering services in Bowmanville Chicago, IL.

Acquiring a HVAC Engineering Firm in Bowmanville Chicago calls for the ability to examine and acknowledge what is needed for your construction. Every individual will likely be different when it comes to the contracting process and it’s better to check out the following qualities.

1) Capability: A good organization will always have accomplished employees onboard to aid with HVAC needs. These professionals are not just trained but will certainly have a number of skill in the trade. This keeps everything simple, streamlined, and as efficient as you need them to be. Clients can seem more comfortable with a professional on hand to help you.

2) Portfolio of employment: Have a look at their reputation to learn how they have done in past times. This might help explain whether or not the company is really a avid team with great results. If you find complications with their portfolio then it’s planning to sort to your put in place. Center on this as quickly as possible!

Here characterize the tips for working with a high-level organization and making sure the answer meets the proper standards. Otherwise, the company can wind up making more issues than solutions. Start with the following tips and prepare a short checklist to have the process easier.

For this reason a lot of engineers are employed as consultants because they gain practice. In those situations, they are only responsible for the following element in the design and could offer understanding on what works or what does not.  Most HVAC systems are founded with the aid of an Bowmanville Chicago HVAC design engineer.

Main HVAC Design Engineer Responsibilities

An HVAC design engineer in Bowmanville Chicago is usually granted a selection of assorted responsibilities based on the company, its requirements, and just how the assignment unfolds.

On the whole, the HVAC design engineer responsibilities will certainly include a variety of duties which includes creating different HVAC systems. All duty will likely be unique since patrons bring customized needs. These requests could include the size of their setup, how it’s gonna operate, and the performance metrics they are after with a brand new HVAC system.

An experienced Bowmanville Chicago HVAC engineer will sit back, comprehend these needs, and plan out a complete HVAC system using high-quality design devices. Things are taken into account throughout this process and that is what HVAC design engineers are relied on to accomplish. As well as creating the HVAC system, the engineer has to ensure the system is done correctly and fits in step with precisely what the client is after.

This is the reason a lot of engineers are employed as consultants because they gain experience. That is when, they might be only accountable for the next element in the process and could provide insight of what works or what does not.  Most HVAC systems are established through the help of an HVAC design engineer in Bowmanville Chicago. There’s only so much you can save this page if you would like more information on the HVAC Engineering services in Bowmanville Chicago, Illinois by New York Engineers you should check out at our blog.

Latest Building Commissioning Related Blog Article

Mechanical Engineering Design Options to Heat and Cool Residential Buildings

Structural Engineering Near Me

There is a broad range of mechanical engineering and design options available for meeting the heating and cooling needs of residential buildings. Normally, these systems differ in terms of the medium used to deliver their heating or cooling output.

  • Water Piping: Water source heat pumps, radiators using chillers, cooling towers, and boilers.
  • Air Ducts: Packaged rooftop units, packaged ceiling hung units
  • Refrigerant Lines: Split AC systems, VRF systems
  • Direct: Used by window-type air conditioners and PTAC units, which operatedirectly between indoor and outdoor locations, without ducts.

This article will provide an overview of some of the most common mechanical design options used for indoor residential spaces, as well as the strengths and limitations of each type of system:

Detailing Mechanical Engineering and Design Options

Mechanical Design Option #1: Four-Pipe System with Chiller, Cooling Tower, and Boiler

This mechanical design gets its name from the fact that it has two separate water circuits, one carrying hot water and another carrying chilled water, each with a supply and return pipe. The basic operating principle of four-pipe systems is the following:

  • Cooling is accomplished by a chiller and cooling tower: A chilled water circuit is used to remove heat from indoor spaces, and the cooling tower is used to reject it outdoors. If the chiller’s compressor comes equipped with a variable-speed drive, this system can offer a very high efficiency in cooling mode.
  • Heating efficiency is determined by the type of boiler. In general, gas-fired boilerstend to be more cost-effective than those running on oil or electrical resistance heating.
  • Fan-coil units are equipped with both hot and cold water coils, granting them the flexibility of either mode of operation.

The main advantage of four-pipe systems is their ability to use both modes of operation simultaneously and independently. This can be especially useful if heating and cooling needs are different across building zones, and especially in apartment buildings and multi-family dwellings where preferences and schedules normally vary by occupant. Of course, a four-pipe system is an expensive mechanical engineering system to install due to the presence of three separate water circuits: two for the distribution of cold and hot water, and a third one used by the chiller to reject heat through the cooling tower.

Mechanical Design Option #2: Water-Source Heat Pumps with Cooling Tower and Boiler

A heat pump can be described in simple terms as a reversible air conditioner: it can deliver indoor cooling through the refrigeration cycle, but can also operate in heating mode with a much higher efficiency than most types of boilers, especially electrical resistance boilers.

Due to their reversible operation, water-source heat pumps offer great flexibility in residential buildings. Individual units can be set to operate in different modes, and in combined heating and cooling applications the overall system can be extremely efficient:

  • Heat pumps in cooling mode extract heat from indoor spaces and release it into a common water circuit.
  • Then, heat pumps in heating mode can extract the heat now carried by the water, and release it indoors, as required.

The fact that heat pumps share the same water circuit means that the cooling tower and boiler only have to balance system loads, rather than meeting them fully:

  • If the cooling load is greater than the heating load, the cooling tower only has to reject the heat difference, not the total heat removed from all spaces.
  • The same logic applies if the heating load is higher than the cooling load: the boiler only has to make up for the difference, not the full heating load.
  • If the heating and cooling loads happen to balance each other out, both the cooling tower and boiler can remain off.

A four-pipe system lacks these capabilities: the chiller must assume the full cooling load while the boiler provides the full heating load – all the heat absorbed in the chilled water loop is rejected by the cooling tower, and can’t be used for space heating purposes because water circuits are independent.

HVAC systems based on water-source heat pumps are extremely efficient, although expensive due to the fact that every zone must be equipped with an individual heat pump, in addition to having a common water circuit, a cooling tower, and a boiler.

Mechanical Design Option #3: VRF System with Rooftop Condensers & Gas Boiler

VRF stands for variable refrigerant flow, and VRF systems get their name from the fact that refrigerant is used to transport heat instead of water:

  • One or more remotely located condensers provide a flow of refrigerant for multiple indoor fan-coils, and a variable speed drive is used to regulate flow according to load. The units can also provide their own heating.
  • For supplementary heating, a gas-fired boiler with perimeter radiation can be added to the system.
  • Two-pipe VRF systems require all fan-coils to operate in the same mode, but with three-pipe systems, it is possible to provide simultaneous heating and cooling for different areas of the building.

Other than operational flexibility, an advantage of this mechanical design option is their ease of installation: refrigerant lines are more compact than water piping and air ducts. These systems still have a relatively small market share in the USA, but are very common in Japan, where they were developed, and Europe. According to ASHRAE, VRF systems tend to have a comparable cost to that of chiller-based systems, potentially higher if the technology must be imported.

The modular nature of VRF systems is another strong point in favor of this technology. If there will be a building expansion, it is possible to expand the system by simply adding a new condenser and the corresponding indoor evaporators.

Mechanical Design Option #4: PTAC Units with Electric Resistance Heating

Packaged terminal air conditioning units (PTAC) are compact systems, very similar to old window-type air conditioners: the system is self-contained and does not require refrigerant lines, water piping, or air ducts, greatly reducing the installed cost. Some PTAC units are equipped with a resistance heater, allowing them to operate in both heating and cooling modes.

PTAC units offer the advantage of being self-contained and independent from each other. This gives them an advantage in projects that will be built in several stages, for example, apartment buildings, since it is possible to expand HVAC capacity as needed without having a common system on which all units depend.

The main limitation of this mechanical system is that they tend to be outclassed by other systems in terms of efficiency, especially when in heating mode. Resistance heating offers a coefficient of performance of 1.0, which means they must draw one watt of electricity per each watt of heating; on the other hand, heat pumps typically operate with a COP of 2.5 or more, or even above 4.0 if a high-efficiency heat pump is selected.

Concluding Remarks

There is a broad range of heating and cooling technologies available for residential buildings, and also a high degree of flexibility in how the overall system can be configured. No system can be considered superior to the rest under all circumstances – every project offers unique conditions that favor some technologies over others.

What kind of mechanical engineering design has worked the best for you? Let us know by commenting below.

Top Searches Related to HVAC Engineering in Bowmanville Chicago, Illinois.

MEP Engineering Basics

HVAC Engineering Bowmanville Chicago, IL

What Can Our HVAC Engineers in Bowmanville Chicago Do For You? Since 2011 a lot of construction companies throughout Plainview, New York already know that NY Engineers is the engineering company to contact when you are ooking for Architectural Engineering in New York City. What many local property owners have not realized is the NY Engineers is also your best choice if you're searching for HVAC Engineering services in Bowmanville Chicago, IL. If [...]

2018-10-06T22:29:51+00:00