Hiring a HVAC Engineering Contractor in Clearing West Chicago

MEP Firm Definition

Many real estate investors throughout Deer Park, NY already know that NY-Engineers.Com is the engineering firm to call if you’re searching for MEP Engineering in NYC. What a lot local construction companies have yet to realized is that New York Engineers is also your top choice if you are looking for HVAC Engineering services in Clearing West Chicago, IL.

Acquiring a HVAC Engineering Company in Clearing West Chicago calls for the opportunity to investigate and comprehend what’s required for your setup. Each person will be different in relation to the signing procedure and it is better to look at these behaviours.

1) Skill: A great organization will invariably have trained staff onboard to help with HVAC requirements. These professionals are not just qualified but are going to have several years of expertise in the trade. This keeps things simple, streamlined, and as well-organized as you require them to be. Customers could feel confident with a specialist on hand to aid.

2) Range of work: Take a look at their reputation to note how they’ve done previously. It can help shed light on if the company is really a avid team who has great outcomes. If there are problems with their portfolio then It is gonna sort into your set up. Concentrate on this as soon as possible!

Here are the strategies for getting a top-tier company and making certain the solution is up to scratch. Otherwise, the organization can wind up having more issues than answers. Start out with these tips and write a short checklist to have the method easier.

This is the reason many engineers are brought on as consultants while they gain skilled. There, they might be only responsible for the next part of the design process and may provide understanding on what works or what doesn’t.  Most HVAC systems are established through the help of an Clearing West Chicago HVAC design engineer.

Key HVAC Design Engineer Tasks

An HVAC engineer in Clearing West Chicago is given a listing of different duties depending on the business, its requirements, and how the assignment evolves.

Generally, the HVAC design engineer duties are going to include a variety of jobs which includes creating different HVAC systems. Every duty will be unique as customers bring customized needs. These demands can incorporate the size of their setup, how it is gonna operate, and the performance metrics they’re after with a brand new HVAC system.

A certified Clearing West Chicago HVAC engineer is going to sit back, recognize these needs, and pre-plan a complete HVAC system using high-quality design instruments. Things are all noted within this time and that is what HVAC design engineers are relied on to perform. Along with designing the HVAC system, the engineer has to be certain the installation is performed as it should be and fits in accordance with exactly what the client wants.

This is why many engineers are employed as consultants while they gain experience. Then, they might be only responsible for the following part in the design and will provide understanding of what works or what doesn’t.  Most HVAC systems are started through the help of an HVAC design engineer in Clearing West Chicago. Even with all of this information you would like additional info about the HVAC Engineering services in Clearing West Chicago, Illinois by NY-Engineers.Com you should stop by at our blog.

Latest MEP Engineering Related Blog Article

An MEP Engineers’ Guide to Air Dampers

M2e Engineering

An air damper is a device that uses valves or plates to stop or regulate the flow of air within a duct, chimney, variable-air-volume (VAV) box, air-handling unit or other similar pieces of equipment. Dampers are also used to stop airflow into unoccupied or unused rooms where air conditioning is not required. In addition, MEP engineers install dampers as protection measures against smoke or fire.

An air damper is a complex mechanism with many moving elements. Their main components are the blades, which adjust their position to control airflow. In addition, dampers include frames, linkages, axles, bearings, seals, blade pins, actuating motors, flanging, jackshafts, and sleeves, among other components.

Types of Air Dampers

Based on their construction, air dampers can be classified into parallel blade and opposed blade dampers. Each configuration has unique performance features and is intended for different applications.

1) Parallel Blade Dampers

In this type of air damper, blades rotate in the same direction, parallel to one another. The parallel blade configuration is typically used when the damper operates in two positions: open or closed.

These dampers redirect air flow along their first few degrees of rotation, as they move from fully open to closed, and therefore control is achieved along the first 20-30% of movement.  Rather than modulating air streams, these dampers change their direction, and that is the main reason why they are preferred for open-close operation or fixed flow control.

Parallel blade dampers are typically used by MEP engineers in applications where the damper represents a major portion of the overall system pressure loss. They should not be used upstream of critical components due to their uneven airflow.

2) Opposed Blade Dampers

In this type of air damper, blades rotate in opposite directions to one another, modulating airflow. These air dampers are mostly used when the system requires airflow control rather than open-close operation, but they can also be used for on-off service.

Opposed blade dampers are typically used in the following applications:

  1. When the damper doesn’t represent a major portion of the overall system pressure loss.
  2. Systems that are required to maintain an even airflow downstream from the damper.
  3. Ducted terminals.

Classification of Dampers by Control Method and Application

Air dampers can also be classified based on the control method they deploy and their intended application. Based on their control method, dampers can be either automatic or manual:

  • Automatic dampers are similar to automatic control valves in terms of functioning.
  • Manual dampers are adjusted manually depending on the required airflow, as implied by their name.

Dampers can also be classified based on their application, and the following are some of the main types:

  • Balancing dampers (volume dampers)
  • Face and bypass dampers
  • Fire dampers
  • Smoke dampers
  • Combined fire and smoke dampers
  • Gravity dampers (backdraft or barometric)
  • Mixing dampers
  • Multi-zone dampers
  • Round dampers
  • VAV boxes (variable-air-volume)

Note how dampers are not only used for air balancing in ventilation systems, but also for safety in fire protection applications.

Why Are MEP Engineers Concerned About Dampers?

Air dampers are an important element of MEP engineering design since their use is subject to code requirements. They should also be designed to minimize energy losses, through the prevention of heat exchange across them when in the closed position, all while maintaining the required pressure conditions in different spaces.

Air dampers are subject to the following codes and standards:

  1. National Fire Protection Association (NFPA) standards:
    1. NFPA 90A Standard for the Installation of Air-Conditioning and Ventilating Systems
    2. NFPA 92A Standard for Smoke-Control Systems Utilizing Barriers and Pressure Differences
    3. NFPA 101 Life Safety Code
  2. Underwriters Laboratories (UL) standards:
    1. UL 555 Standard for Fire Dampers
    2. UL 555S Standard for Smoke Dampers
    3. UL 555C Standard for Ceiling Dampers

The main locations where air dampers are required to meet code are the following: stair enclosures, elevator shafts, common corridors, mechanical rooms, fire-rated walls, exterior building walls, shaft enclosures, horizontal assemblies, and duct and transfer openings.

Air Dampers in Fire Protection Applications

The three main types of dampers used in fire protection applications are fire dampers, smoke dampers, and combined fire/smoke dampers. This section provides an overview of each type and its applications.

Fire Dampers

Fire dampers interrupt airflow through the duct automatically, restricting the passage of flames. To accomplish their function, these dampers are installed in ducts that cross fire-rated assemblies or fire-rated walls. They can be installed in both horizontal and vertical ductwork and can be of both curtain type and multi-blade type.

A fire damper has the following components:

  1. Sleeve
  2. Curtain blade
  3. Break-away joints
  4. Fusible link
  5. Access door to inspect the fire damper

All fire dampers are installed in the open position, with a fusible link. When the temperature in the ductwork exceeds a specified value, the fusible link melts and the damper gets shut off, either by gravity or by a spring. To guarantee they accomplish their function, fire dampers need to pass various tests.

Fire damper selection is based on three main factors: fire resistance rating, temperature, and operating range. Fire rating depends on the time span for which a damper will withstand the heat associated with a fire. For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire dampers are used. This procedure ensures building code compliance, which requires that the fire resistance rating is maintained across the full area of walls, partitions, and floors.

The exceptions for the use of fire dampers are parking garages, kitchen exhaust ductwork, and dryer exhaust ductwork.

Smoke Dampers

Smoke dampers prevent smoke from spreading in HVAC systems that are designed to shut down automatically in case of fire, and they only have two positions: open and closed. These dampers are installed in a slotted duct section – they are installed whenever a duct penetrates a smoke partition or smoke barrier inside the building. They can be applied in passive smoke control systems, or as part of an engineered smoke control solution.

In passive systems, smoke dampers close and prevent the circulation of air and smoke through ducts or ventilation openings that cross a smoke barrier. On the other hand, in engineered smoke control systems, the spread of smoke is controlled by the building HVAC system or by dedicated fans that create pressure differences. Smoke dampers may be controlled by heat sensors, smoke sensors, fire alarms, or any other method that meets the design intent.

A smoke damper has the following components:

  1. Sleeve
  2. Smoke blades (parallel)
  3. Break-away joints
  4. Duct-mounted smoke detector
  5. Damper actuator
  6. Access door

It is important to decide which ratings are required for UL Listed fire dampers.

  • The SD-1320 and SD-1330 smoke dampers are UL/cUL leakage rated dampers, listed under the latest UL 555S standard.
  • SD-1620 smoke dampers meet UL Class II. Leakage is less than 20 cfm per square foot at 4 inch w.g. and at 350°F (177°C).
  • SD-1630 smoke dampers meet UL Class I. Leakage is less than 8 cfm per square foot at 4 inch w.g. and at 350°F (177°C).

Fire and Smoke Damper (Combined)

As implied by its name, this type of damper is a combination of a fire damper and a smoke damper, and it is installed in ducts that cross partitions rated as both fire and smoke barriers. This type of damper must be qualified under both UL555 and UL555S.

Selection of a combined fire and smoke damper depends upon 4 factors: fire resistance rating, leakage rating, temperature and operational ratings.

Combined fire and smoke damper applications include walls, floors, partitions required by the local building code.

For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire/smoke dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire/smoke dampers are used. Designers are usually suggested to pick a very low leakage category.

Conclusion

Air dampers have a wide range of applications, ranging from airflow modulation in normal operating conditions to providing a reliable barrier against smoke or fire during emergencies. However, code compliance is an important aspect to consider regardless of the application, so working with qualified MEP engineers is highly recommended.

Top Searches Related to HVAC Engineering Clearing West Chicago, IL.

MEP Consulting Engineers

HVAC Engineering Clearing West Chicago, IL

What Can Our HVAC Engineers in Clearing West Chicago Do For You? Over the last decade a lot of property owners throughout Bay Shore, New York already know that NY-Engineers.Com is the engineering company to contact when you are ooking for Mechanical Engineering in NY. What a lot local property owners have not realized is the New York Engineers is also your best choice if you are searching for HVAC Engineering services [...]