Many construction companies throughout Dix Hills, New York already know that NY-Engineers.Com is the engineering firm to call when you are looking for Mechanical Engineering in NY. What a lot local construction companies have yet to realized is that NY-Engineers.Com is also your top choice if you are looking for HVAC Engineering services in Lisle, Illinois.

Acquiring a HVAC Firm in Lisle requires the ability to investigate and recognize what is required for your setup. Every person will probably be dissimilar in relation to the hiring process and it is better to think about the following traits.

1) Capability: An effective organization will usually have accomplished professionals onboard to help you with HVAC requirements. These professionals aren’t just trained but will certainly have a number of skill in the marketplace. This keeps everything simple, streamlined, and as efficient as you want them to be. Clients will be at ease with a specialist on hand to help you.

2) Portfolio of employment: Have a look at their track record to learn exactly how they’ve done previously. It could help shed light on whether or not the organization is really a avid team with good results. If you find difficulties with their portfolio then It is planning to filter into the set up. Focus on this at the earliest opportunity!

These represent the methods for getting a top-tier firm and ensuring the answer is up to scratch. If not, the organization can find themselves causing more problems than solutions. Get started with these tips and create a simple list to have the process easier.

This is the reason most engineers are hired as consultants while they get skilled. There, they might be only accountable for the following step in the style and may offer understanding of what works or what doesn’t.  Most HVAC systems are started with the help of an Lisle HVAC design engineer.

Main HVAC Design Engineer Tasks

An HVAC design engineer in Lisle is granted a selection of different duties dependant upon the business, its needs, and how the assignment unfolds.

On the whole, the HVAC design engineer responsibilities are going to contain a number of tasks including creating various HVAC systems. Each duty will likely be exclusive as patrons bring modified needs. These bids might include the size of their setup, how it’s gonna work, and the performance metrics they are after with a brand new HVAC system.

An experienced Lisle HVAC engineer will take a seat, recognize these needs, and plan out a complete HVAC system with high-quality design tools. Things are taken into account during this procedure and that’s what HVAC design engineers are expected to do. In addition to designing the HVAC system, the engineer has to be certain the system is carried out properly and fits in step with precisely what the requester is after.

This is the reason most engineers are brought on as consultants because they get experience. Then, they might be only responsible for the following step of the style and would give insight on what works or what does not.  Most HVAC systems are founded through the help of an HVAC design engineer in Lisle. There’s only so much you can save this page if you would like more information about the HVAC Engineering services in Lisle, Illinois by NY-Engineers.Com we invite you to visit at our blog.

Construction Administration Related Article

An MEP Engineers’ Guide to Air Dampers

Value Engineering Examples

An air damper is a device that uses valves or plates to stop or regulate the flow of air within a duct, chimney, variable-air-volume (VAV) box, air-handling unit or other similar pieces of equipment. Dampers are also used to stop airflow into unoccupied or unused rooms where air conditioning is not required. In addition, MEP engineers install dampers as protection measures against smoke or fire.

An air damper is a complex mechanism with many moving elements. Their main components are the blades, which adjust their position to control airflow. In addition, dampers include frames, linkages, axles, bearings, seals, blade pins, actuating motors, flanging, jackshafts, and sleeves, among other components.

Types of Air Dampers

Based on their construction, air dampers can be classified into parallel blade and opposed blade dampers. Each configuration has unique performance features and is intended for different applications.

1) Parallel Blade Dampers

In this type of air damper, blades rotate in the same direction, parallel to one another. The parallel blade configuration is typically used when the damper operates in two positions: open or closed.

These dampers redirect air flow along their first few degrees of rotation, as they move from fully open to closed, and therefore control is achieved along the first 20-30% of movement.  Rather than modulating air streams, these dampers change their direction, and that is the main reason why they are preferred for open-close operation or fixed flow control.

Parallel blade dampers are typically used by MEP engineers in applications where the damper represents a major portion of the overall system pressure loss. They should not be used upstream of critical components due to their uneven airflow.

2) Opposed Blade Dampers

In this type of air damper, blades rotate in opposite directions to one another, modulating airflow. These air dampers are mostly used when the system requires airflow control rather than open-close operation, but they can also be used for on-off service.

Opposed blade dampers are typically used in the following applications:

  1. When the damper doesn’t represent a major portion of the overall system pressure loss.
  2. Systems that are required to maintain an even airflow downstream from the damper.
  3. Ducted terminals.

Classification of Dampers by Control Method and Application

Air dampers can also be classified based on the control method they deploy and their intended application. Based on their control method, dampers can be either automatic or manual:

  • Automatic dampers are similar to automatic control valves in terms of functioning.
  • Manual dampers are adjusted manually depending on the required airflow, as implied by their name.

Dampers can also be classified based on their application, and the following are some of the main types:

  • Balancing dampers (volume dampers)
  • Face and bypass dampers
  • Fire dampers
  • Smoke dampers
  • Combined fire and smoke dampers
  • Gravity dampers (backdraft or barometric)
  • Mixing dampers
  • Multi-zone dampers
  • Round dampers
  • VAV boxes (variable-air-volume)

Note how dampers are not only used for air balancing in ventilation systems, but also for safety in fire protection applications.

Why Are MEP Engineers Concerned About Dampers?

Air dampers are an important element of MEP engineering design since their use is subject to code requirements. They should also be designed to minimize energy losses, through the prevention of heat exchange across them when in the closed position, all while maintaining the required pressure conditions in different spaces.

Air dampers are subject to the following codes and standards:

  1. National Fire Protection Association (NFPA) standards:
    1. NFPA 90A Standard for the Installation of Air-Conditioning and Ventilating Systems
    2. NFPA 92A Standard for Smoke-Control Systems Utilizing Barriers and Pressure Differences
    3. NFPA 101 Life Safety Code
  2. Underwriters Laboratories (UL) standards:
    1. UL 555 Standard for Fire Dampers
    2. UL 555S Standard for Smoke Dampers
    3. UL 555C Standard for Ceiling Dampers

The main locations where air dampers are required to meet code are the following: stair enclosures, elevator shafts, common corridors, mechanical rooms, fire-rated walls, exterior building walls, shaft enclosures, horizontal assemblies, and duct and transfer openings.

Air Dampers in Fire Protection Applications

The three main types of dampers used in fire protection applications are fire dampers, smoke dampers, and combined fire/smoke dampers. This section provides an overview of each type and its applications.

Fire Dampers

Fire dampers interrupt airflow through the duct automatically, restricting the passage of flames. To accomplish their function, these dampers are installed in ducts that cross fire-rated assemblies or fire-rated walls. They can be installed in both horizontal and vertical ductwork and can be of both curtain type and multi-blade type.

A fire damper has the following components:

  1. Sleeve
  2. Curtain blade
  3. Break-away joints
  4. Fusible link
  5. Access door to inspect the fire damper

All fire dampers are installed in the open position, with a fusible link. When the temperature in the ductwork exceeds a specified value, the fusible link melts and the damper gets shut off, either by gravity or by a spring. To guarantee they accomplish their function, fire dampers need to pass various tests.

Fire damper selection is based on three main factors: fire resistance rating, temperature, and operating range. Fire rating depends on the time span for which a damper will withstand the heat associated with a fire. For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire dampers are used. This procedure ensures building code compliance, which requires that the fire resistance rating is maintained across the full area of walls, partitions, and floors.

The exceptions for the use of fire dampers are parking garages, kitchen exhaust ductwork, and dryer exhaust ductwork.

Smoke Dampers

Smoke dampers prevent smoke from spreading in HVAC systems that are designed to shut down automatically in case of fire, and they only have two positions: open and closed. These dampers are installed in a slotted duct section – they are installed whenever a duct penetrates a smoke partition or smoke barrier inside the building. They can be applied in passive smoke control systems, or as part of an engineered smoke control solution.

In passive systems, smoke dampers close and prevent the circulation of air and smoke through ducts or ventilation openings that cross a smoke barrier. On the other hand, in engineered smoke control systems, the spread of smoke is controlled by the building HVAC system or by dedicated fans that create pressure differences. Smoke dampers may be controlled by heat sensors, smoke sensors, fire alarms, or any other method that meets the design intent.

A smoke damper has the following components:

  1. Sleeve
  2. Smoke blades (parallel)
  3. Break-away joints
  4. Duct-mounted smoke detector
  5. Damper actuator
  6. Access door

It is important to decide which ratings are required for UL Listed fire dampers.

  • The SD-1320 and SD-1330 smoke dampers are UL/cUL leakage rated dampers, listed under the latest UL 555S standard.
  • SD-1620 smoke dampers meet UL Class II. Leakage is less than 20 cfm per square foot at 4 inch w.g. and at 350°F (177°C).
  • SD-1630 smoke dampers meet UL Class I. Leakage is less than 8 cfm per square foot at 4 inch w.g. and at 350°F (177°C).

Fire and Smoke Damper (Combined)

As implied by its name, this type of damper is a combination of a fire damper and a smoke damper, and it is installed in ducts that cross partitions rated as both fire and smoke barriers. This type of damper must be qualified under both UL555 and UL555S.

Selection of a combined fire and smoke damper depends upon 4 factors: fire resistance rating, leakage rating, temperature and operational ratings.

Combined fire and smoke damper applications include walls, floors, partitions required by the local building code.

For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire/smoke dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire/smoke dampers are used. Designers are usually suggested to pick a very low leakage category.

Conclusion

Air dampers have a wide range of applications, ranging from airflow modulation in normal operating conditions to providing a reliable barrier against smoke or fire during emergencies. However, code compliance is an important aspect to consider regardless of the application, so working with qualified MEP engineers is highly recommended.

Searches Related to HVAC Engineering Lisle, IL.

Fire Protection Engineering Schools

HVAC Engineering Lisle, IL

What Can Our HVAC Engineers in Lisle Do For You? If you're looking for a competent HVAC Engineering in Chicago? The one to go to is NY-Engineers.Com. Not only for HVAC Engineering in Chicago but also Architectural Engineering and Sprinkler Design Engineering throughout Lisle. Call us at (+1) 312 767.6877 Since 2011 the majority of developers throughout Jamestown, NY already know that NY Engineers is the engineering firm to contact when [...]