MEP Engineer Service Columbus Ohio

What Do Architectural Engineers Do

The majority of builders from Montana to Oregon have come to recognize NY-Engineers.Com as a firm they can count on for Utility Filings Engineering Services. What a lot of people in the trade have not realize is that MEP.NY-Engineers.Com, is the top option for anyone looking for MEP Engineering Service near Columbus Ohio.

This has to do with developments including many parts specially in construction. With so many moving parts, it becomes doubly important to use a lead strategist to deal with everything and make certain all standards are upheld from beginning to conclusion.  This is why MEP engineering enters  the discussion. It’s also referred to as MEP engineering.

In essence, the responsibility of hired for this job is to manage the project and make certain all of these components are administered wisely. This will include having knowledge of operating costs, budgeting for specific changes and making sure other inspection mechanisms are in position from day one. This really is the best way to ensure that the results are valid and the task continues to move smoothly.

With an MEP engineer in Columbus Ohio, there will likely be different assignments handed out which is always going to come back to this particular particular engineer when it is time to figure out what is working or what is not.

An MEP engineer is a specific position that is meant to handle these various details while ensuring that everything works in harmony from day one. Whether it be establishing strategies, examining new changes, or highlighting particular steps, everything is carried out by the engineer. These professionals have sufficient knowledge and can identify the intricacies of every position in depth.

MEP Engineers versus Electrical Engineers in Columbus Ohio

The normal individual is aware of what an electrical engineer is but they might not have haard of an MEP engineer. Let’s take a look at this comparison of MEP engineers versus electrical engineers.

MEP Engineer

This is mechanical, electrical and plumbing, which demonstrates what the engineer is in charge of. Generally, an MEP engineer is answerable for management and planning in the area of mechanical, electrical, or plumbing systems. This will include the addition of exact plans/policies/details to optimize the basic strategy laid out for the job at hand. They will also be inspired to do all this while creating specific inspection standards within the determined budget.

Electrical Engineer

These specialized professionals are reserved for electrical projects. Their skils revolves around electronics, electromagnetism and the general utilization of electricity. This may be noticed in many forms but it is a specialization that is specifically studied for by these pros. In contrast, an MEP engineer in Columbus Ohio includes a more diversified procedure for managing projects and may have got a greater amount of duties in comparison with a power engineer. However, the electrical engineer is far more specialized if it relates to anything associated with electricity since that is their main specialized skillset. At NY Engineers, we are aware that a lot of many individuals don’t know that we offer MEP Engineer in Columbus Ohio, that is why we urge everyone to take a look our Sprinkler Engineering Services blog!

Blog Article Related to MEP Engineering Service near Columbus Ohio

How Construction Engineers are Improving HVAC Efficiency in Commercial Buildings with Variable Frequency Drives

Electrical Engineering Schools

HVAC systems come in various configurations that differ significantly from each other. For example, an air conditioning system based on packaged rooftop units is drastically different from a chiller plant. However, HVAC installations have a common denominator: they use electric motors that are subject to variable loads. Regardless of whether these motors are used to drive compressors, water pumps or fans, construction engineers understand that there is a great opportunity to save energy by optimizing part-load operation.

In general, running a motor at partial speed is more energy-efficient than running it intermittently at full speed.

  • Intermittent operation only provides linear savings. For example, a cooling tower fan with a duty cycle of 80% consumes 20% less energy than an identical fan operating full-time.
  • Reducing motor speed provides cubic savings.. On the other hand, slowing down a fan to 80% speed reduces energy consumption by nearly 50%. The average airflow is the same as that of a fan running at full power 80% of the time, but savings are boosted significantly thanks to speed control.

Speed control can be accomplished with variable-frequency drives (VFD), and they have a broad range of applications in HVAC systems due to the cyclic nature of loads. It is important to note that VFDs are also known as variable-speed drives (VSD), adjustable-frequency drives (AFD) or adjustable-speed drives (ASD).

Fractional horsepower motors in small-scale HVAC systems can also achieve significant savings with speed control. The main difference here is that electronically commutated motors (ECMs) are more cost-effective than VFDs in these applications.

Ask a Construction Engineering Expert: How Does Variable Frequency Drive Work?

As explained by electrical engineering textbooks, the speed of an electric motor is defined by the power supply frequency and its internal construction. For example, a motor running at 1800 RPM with the 60 Hz USA power supply would run at 1500 RPM in the UK, where the frequency is 50 Hz. Thus, if a motor is suitable for operation at reduced frequency, its speed can be ramped down during part load conditions to achieve energy savings. VFDs are connected between the power supply and the motor, adjusting voltage and frequency as a means of speed control.

In applications where only single-phase power is available, VFDs can be used to integrate three-phase motors while achieving the energy efficiency benefits: there are models capable of producing a three-phase voltage from a single-phase input, while adjusting magnitude and frequency to control motor speed.

In addition to improving energy efficiency, VFDs allow motors to be soft-started by gradually ramping up the voltage and frequency, as opposed to directly applying full voltage at 60 Hz. Electric motors draw from five to eight times their rated current when started directly, and the voltage drop that results from the inrush current may damage sensitive equipment.

The main limitation of VFDs is that they produce a phenomenon called harmonic distortion, where high-frequency currents are induced in branch circuits. However, this can be controlled with a properly-specified harmonic filter; this device absorbs current distortions at the point of consumption, preventing their propagation throughout the installation.

VFD Applications in HVAC Systems

In most cases, VFDs are deployed by construction engineers in HVAC systems to control the speed of blower fans, pumps or compressors.

Cooling Tower Fans

The main purpose of a cooling tower is removing the heat from a water circuit, which may be used in turn for process cooling or for a chiller plant. Cooling towers use fans to establish an airflow, improving heat removal through convection. These are open discharge fans, where there is no ductwork creating resistance to airflow; hence, the savings opportunity through speed control is significant.

When a VFD is deployed for a cooling tower fan, speed is normally controlled based on water temperature. Rather than cycling the fan on and off, it can be driven at reduced speed so that the water returning to the chiller or process is kept at a constant temperature – as previously explained, reduced-speed operation is far more efficient than intermittent operation at full speed.

Air-Handling Units and Packaged Rooftop Units

Unlike the fans in cooling towers, those used in AHUs and packaged RTUs blow air into a duct system, which offers higher resistance and requires a specific static pressure and airflow to be established. These ducts may have several outlets with variable-air-volume (VAV) boxes, where airflow is controlled individually for each zone with a damper.

Without a VFD, the blower fan in the AHU or RTU operates at full speed, and each VAV box is adjusted individually. This is an inefficient approach, however – if neither of the VAV boxes is fully open, energy is being wasted in the form of extra pressure. On the other hand, if the blower is equipped with a VFD, an interesting energy-saving strategy becomes possible:

  • Blower speed can be gradually reduced while VAV boxes are opened incrementally, to keep the airflow and temperature constant.
  • The temperature of different zones is unaffected but pressure is reduced, saving energy.
  • Speed reduction continues until one of the VAV boxes reaches the fully open position. At this point it is not possible to reduce speed further without affecting indoor temperatures.

There is also a comfort benefit with this control strategy: the reduced pressure drop translates into less noise, making indoor environments more comfortable.

Speed Control for Water Pumps

Water circuits are a key element of many HVAC installations, including those that use chillers, boilers and water-source heat pumps. Since HVAC loads are variable, it is often necessary to adjust the water flow depending on total system load. There are three main ways to achieve this:

  • Choke Valve-A choke valve is installed in line with the flow, and as implied by its name it regulates flow by closing partially. This control method is simple, but the resulting pressure loss represents a considerable waste of energy.
  • Recirculation Valve-With this approach a valve is installed on a parallel recirculation circuit, and it is opened gradually to divert a part of the water flow, reducing the flow in the main circuit. In this case, however, there is also a significant energy loss because the recirculated water represents pumping power.
  • Pump Speed Control– The most energy efficient approach is to install a VFD on the pump motor. If a reduced water flow is required, it is just a matter of reducing the pump speed accordingly. With no pressure or recirculation losses, the savings achieved are significant. This setup also uses a choke valve for convenience, but it is normally kept in the fully open position, since the VFD regulates flow.

Chillers with Variable-Speed Compressors

In chilled water air conditioning systems, the chiller is by far the piece of equipment with the highest energy consumption. Therefore, installing the most efficient chiller model that can be afforded is highly recommended.

Energy efficient chillers have helical rotary compressors, capable of adjusting their speed with a VFD, depending on cooling needs. Some models may feature multiple individual compressors to achieve enhanced flexibility and increased part-load efficiency.

When a chiller is highly efficient, the control strategy is normally based on maximizing its capacity rather than running it at the lowest possible set point. The savings achieved by reducing the load on complementary systems tend to be far greater than the extra consumption at the chiller. There are exceptions, of course, and only monitoring and control can offer the correct answer 100% of the time.

Integrating the Entire HVAC System

Equipping all motors in an HVAC system with VFDs is a first step towards energy efficiency, but the best results can only be achieved with central control system, capable of assessing building conditions and adjusting HVAC set points in real time.

The interaction between a chiller and a cooling tower is a great example of how control engineering and VFDs can be applied to HVAC installations:

  • Reducing the cooling tower fan speed increases the cooling load on the chiller.
  • The reverse also applies: reducing refrigeration power at the chiller may require more heat to be rejected by the cooling tower.

If the chiller has a high efficiency, the best option in most scenarios is reducing the cooling tower load. However, only a control system can balance the operation of both components in real time. Ideally, the control system should be able to determine the set point for each individual VFD so that power consumption is minimized at the total system level.

Of course, the performance of an HVAC system starts from the design phase. For optimal results, make sure you work with licensed and qualified construction engineers and other HVAC professionals. Installing an efficient and automated HVAC system from the start is much less expensive than upgrading an existing installation.

MEP Engineering Books

Electrical Engineer Service Columbus Ohio

Electrical Engineer Services in  Columbus Ohio From Maryland to New York construction companies have come to rely on New York Engineers when they need reliable MEP Engineering Services near Columbus Ohio. With that said, it is imperative to note that we are more than that. We are eight national engineering firm offering design but also consultation services. Even though our focus is in mechanical, electrical and plumbing (MEP) installations. We offer a [...]

2019-03-01T22:44:54+00:00

MEP Engineer Service in Columbus Ohio

MEP Engineer Service Columbus Ohio Many top builders throughout Georgia are aware that New York Engineers is the right candidate if you are looking for CAD to Revit Modeling. With that said, due to its fast growth many general contractors have failed to our knowledge that New York Engineers is perhaps top partner if you're searching for MEP Engineering Service near Columbus Ohio. MEP means mechanical, electrical, and plumbing. Specifically, throughout the [...]