MEP Service in Arlington Heights, IL.

Contact Us

Looking for the top MEP Firms in Chicago? Your best bet is to call is NY Engineers. Not only for MEP Firms in Chicago but also HVAC Engineering and Protection Engineering near Arlington Heights. Contact us at (+1) 312 767-6877

Contact Us
MEP Engineers

Building owners throughout North Amityville, New York have come to depend on NY Engineers for a wide range of engineering services ranging from Sprinkler Engineering to CAD to Revit Modeling. This is why property owners in Arlington Heights will tell you that if you are searching for a dependable MEP Engineering firm in Arlington Heights, Illinois you need to consider NY-Engineers.Com.

Chances are, you might have walked into any particular type of building and seen the outcome of MEP Engineering. Simply put, MEP focuses in the mechanical, electrical and plumbing aspects of engineering. Essentially, the name already gives a clue to the most common and precise assumption of what is MEP. This article should go into some details of what is MEP Engineering.

So far as the mechanical aspect is concerned, for residential and commercial engineering, this deals with anything which moves. In addition its entails using complex and uncomplicated machines along with other mechanical mechanisms to carry out certain tasks. Some everyday mechanical engineering tasks that may be noticed everyday are HVAC units, kitchen or bath exhausts, cooling and heating air systems and equipment and systems that handle boosting the energy productivity.

The electrical element of construction is centered on the electrical safety, functions, components, and above all, the wiring for any building. Engineers with this branch try very hard to ensure the layout of a building are designed to deliver sufficient power to every component in a safe manner ensuring that all of the electrical codes are followed. Some common electrical engineering tasks can be found in the lighting design, modifying the voltage and allocating the electricity to every component inside the building which needs a supply.

With regards to plumbing, there is certainly a wide array of plumbing factors which constitute the final form of any structure. Plumbing engineering goes deeper than just faucets, toilets, and sinks, and contains many behind the scene appliances. These being the sewage and drainage lines along with the buildings household water supply and how it flows.

As we conclude this article we certainly have just checked out what is MEP Engineering. MEP Engineering is administered within the construction industry. And, aids in completing the often ignored technical elements of any building.

Hiring an MEP Engineering Firm in Arlington Heights is Important for Major Construction Projects

Using an MEP company in Belmont Central Chicago, Illinois, might have everything to do with the achievements of your construction project. These specialists will help offset the cost of making this type of hiring decision when it comes to energy management alone. When you find yourself talking about large commercial buildings, energy conservation is really a topic of discussion. It’s time to discover a few other great reasons behind hiring MEP company in Avondale Chicago, IL.

Engineers have a lot to do with the physical reliability of the building. If you may well imagine, it means the unseen is very important. Design not merely deals in aesthetics but the foundation of a building also its components. That is yet another solid good reason that using an MEP engineering company will be helpful to any project.

Think of each of the pipes and plumbing. Look at the heating and air conditioning systems and the importance of getting all its components in the correct places. Energy saving was discussed, and energy competence can be another significant term to bring up. Energy competence concerns your HVAC system, and it plays a huge role in energy maintenance overall.

Consider your building’s foundation. Consider installing home security systems along with the safety and security measures put in place throughout the structure. With everything else described up to now, it’s reliable advice that numerous aspects of building construction could be either overlooked or minimized without MEP experts at the job.

Now with all you have read you will look to find the best MEP engineering company in the business, right? It’s pretty clear the best engineers really need to be working in the massive construction of commercial buildings. Personalized will be the right term to make use of to clarify just how these experts will customize a construction project to meet the needs of your own operations. Even with all of this information you would like more info about the MEP Engineering services in Arlington Heights, Illinois by NY-Engineers.Com you should stop by at our Arlington Heights Construction Administration blog.

New MEP Engineering Related Blog Article

Basic Concepts of Lighting Design, According to Electrical Engineers

Fire Protection Engineering UMD

Lighting system design is a very important aspect of construction projects, and the best performance is achieved when lighting is specified through detailed calculations and not “rules of thumb” by electrical engineers. However, lighting has a key difference with other building systems like HVAC and plumbing: there is a subjective and artistic factor involved. Lighting systems must provide adequate visibility, but they also set the ambiance of built environments.

Effective communication is important in any engineering design process, and this is only possible if the parties involved are familiarized with key technical concepts. This article will provide an overview of the main terms used when specifying lighting systems.

The Lumen: Basic Unit of Luminous Flux

Just like electric current is measured in amperes and water flow is measured in gallons per minute, the lighting output of a lamp or fixture is measured in lumens. Watts are often used to describe the brightness of lamps, but this is an incorrect practice that leads to confusion:

  • A few decades ago when all light bulbs were incandescent, wattage could be used to describe brightness because there was a direct relationship between lumens provided and watts consumed.
  • However, this leads to confusion when comparing different types of lighting. For example, the lumen output is roughly the same for a 60W incandescent bulb, a 15W compact fluorescent light, and a 9W LED bulb.

A common misconception about LED lighting is that you end up with a darker room due to the reduced wattage. However, this comes from the old practice of describing brightness with watts, when the correct unit is the lumen.

The concept of luminous efficacy describes how efficiently a lamp converts watts of electricity into lumens, similar to the gas mileage (MPG) of a car. Just like a car with a higher MPG value has a lower fuel cost for a given distance travelled, a light source with a higher lm/W value has a lower electricity cost for a given lighting output. Upgrading to LED lighting is one of the most cost-effective energy efficiency measures for a building.

Lumens are useful when describing the output of a lamp or fixture, but a different measurement unit is required to describe the lighting needed by a specific area. For example, 10,000 lumens is more than enough lighting for a small office, but the effect is barely noticeable in a large warehouse. When describing the required lighting in built environments, the concept of illuminance is used.

Illuminance: Lumens per Unit of Area

The concept of illuminance is used to describe the lighting required for a given occupancy, regardless of size. There are two common measurement units:

  • Lux, or lumens per square meter.
  • Footcandle (fc), or lumens per square foot.
  • 1 fc = 10.7639 lux

Since illuminance is specified per unit of area, room size does not matter. For example, an illuminance of 50 fc has the same meaning for a 500 sq. ft. office and for a 2500 sq. ft. office, with the difference that more lighting fixtures are required for the larger office. Illuminance values are specified by the Illuminating Engineering Society of North America (IESNA) in their Lighting Handbook.

In actual lighting design, the illuminance level varies due to the spacing of fixtures and their beam shapes. However, slight variations are acceptable as long as no areas are too dark or too bright. Illuminance is determined not only by the lighting distribution, but also by room features such as ceiling height and surface colors – manual calculations are very complex, but the process is automated with software in modern lighting design. Electrical engineers know how to create lighting designs that are ideal for a space, thus preventing wildly varying illuminance levels.

Photometry: What is the Beam Shape of Lamps and Fixtures?

Light beam shape is another important aspect considered by lighting designers. For example, spotlights concentrate their output into a narrow beam facing downwards, while troffers in offices spread their output over the largest possible area to achieve uniform lighting.

Do not assume that two light bulbs can be used for the same application just because their bases have the same shape. Using a light source with the wrong beam shape yields poor results even if the lumen output is calculated correctly.

The beam shape of a lamp or fixture is three-dimensional, and product models used in lighting design software include this information for simulation purposes. On the other hand, a 3D beam shape cannot be represented in technical specifications; the beam is described with overlapping 2D figures that represent beam shape parallel and perpendicular to the light source.

Correlated Color Temperature and Color Rendering Index

Describing the color performance of lighting requires two separate metrics, one for the light source and another for the objects it illuminates.

  • The correlated color temperature (CCT) describes the color of the light source itself. When dealing with the CCT, no value is considered “the best”, since each lighting hue has different applications.
  • The color rendering index (CRI) describes how faithfully the light source renders the colors of objects and surfaces in the room. The maximum CRI value is 100, describing a light source that matches the quality of natural light – a higher CRI is always better regardless of the application.

How Electrical Engineers Use Temperature Values To Describe Lighting Color

Objects glow in a characteristic color depending on their temperature, and this is why lava from a volcano looks red. The same principle applies to stars, where a yellow star like the Sun is hotter than a red star, and a blue star is hotter than a yellow one. In physics, this behavior is described by an abstract concept called a “black body”, which is an object that emits no light except when heated, and each temperature corresponds with a specific color glow.

Light sources are not heated to the temperature implied by their CCT value, but it is a convenient way to assign a numerical value to their color. In most residential and commercial applications, the CCT value of lighting ranges from 2700K (yellowish white) to 6500K (bluish white). In other words, if a light product has a CCT of 4000K, it means it glows with the same color as a “black body” at 4000K, but the light source itself does not reach that temperature!

Although personal preference plays a role in CCT selection, the following principles apply to most lighting designs:

  • Low color temperatures like 2700K are perceived as “warm” and they tend to have a relaxing effect. They are preferred in areas like residential bedrooms, hotel rooms and high-end restaurants. Warm colors are not well suited for commercial and industrial settings, where the relaxing effect can be counterproductive.
  • High color temperatures like 6500K are perceived as “cool” and they tend to have an energizing effect, enhancing. They are preferred in applications where maximum visibility is required, such as high-precision manufacturing. Cool colors may delay sleep when used in residential and hospitality settings, and extended exposure may be described as “stressful” by some individuals.
  • CCT values around 4000K are perceived as “neutral” and they offer a balance point between the two extremes described above. Neutral white is the lighting color of choice for offices, classrooms, kitchens and similar locations where concentration is required for extended periods.

Effect of the Light Source on Objects and Surfaces

Even if two light sources have the same CCT value, their lighting quality may differ. A CRI value of 100 means the light source is a good as sunlight.

  • Despite their inefficiency, incandescent and halogen bulbs offer a CRI of 100.
  • Fluorescent bulbs tend to have the lowest color rendering performance, and low-tier products can go below 70.
  • CRI values for LED bulbs can vary significantly depeding on product quality. Low-end products go below 70, while high-performance products reach values close to 100.

The minimum CRI for a light bulb to get the ENERGY STAR label is 80. Therefore, looking for the label is an effective strategy to avoid lamps with poor color performance, and you can also rest assured that the product has passed rigorous laboratory tests. When dealing with LED bulbs, a higher CRI typically comes with a higher price tag, but there are applications where the CRI metric is very important – consider retail and art galleries, for example.

Conclusion

LED upgrades have the potential to reduce lighting power consumption by over 50 percent. If the space is air-conditioned, indirect savings are achieved by reducing the heat footprint of lamps and fixtures. It can be tempting to simply swap the existing lighting with the most efficient product available, but lighting design must not be overlooked, say electrical engineers – lighting savings should not be achieved at the expense of quality.

Popular searches related to Fire Protection Engineering in Arlington Heights, Illinois.

Construction Engineering Courses

(MEP) Engineering Service in Arlington Heights

MEP Engineers Arlington Heights! If you re looking for a competent MEP Chicago in Firm? The top choice is is NY Engineers. Not only for MEP Firms in Chicago but also Architectural Engineering and Protection Engineering in or near Arlington Heights. Call us at (+1) (312) 767-6877 Quite a few developers throughout Saratoga Springs, NY have come to rely on NY Engineers for a wide range of engineering services ranging from [...]