MEP Service in Ashburn Estates Chicago, Illinois.

Contact Us

Searching for a top MEP Chicago? The one to go to is NY Engineers. Not only for MEP Firms in Chicago but also Mechanical Engineering and Sprinkler Design Engineering throughout Ashburn Estates Chicago. Call (+1) 312 767.6877

Contact Us
Mechanical Engineering Career

Construction companies throughout Eastchester, New York have come to rely on NY Engineers for a wide range of engineering services ranging from Electrical Engineering to Construction Administration. For this reason property owners in Ashburn Estates Chicago will tell you that if you are looking for a top-rated MEP Engineering firm in Ashburn Estates Chicago, Illinois you need to consider NY-Engineers.Com.

It is very possible, you may have walked into any specific type of building and seen the outcomes of MEP Engineering. To put it simply, MEP focuses around the mechanical, electrical and plumbing elements of engineering. Basically, the name already gives a clue to the most prevalent and accurate notion of exactly what is MEP. Our article should go into some information on what is MEP Engineering.

As far as the mechanical side is concerned, for residential and commercial engineering, this handles anything which moves. Moreover its involves the usage of complex and straightforward machines as well as other mechanical mechanisms to perform certain tasks. Some ordinary mechanical engineering tasks that can be noticed everyday are HVAC units, kitchen or bath exhausts, cooling and heating air systems and equipment and systems which take care of increasing the energy efficiency.

The electrical part of construction is centered on the functions, components, electrical safety, and above all, the wiring associated with a building. Engineers with this section try very hard to ensure the layout of a building are made to bring ample electricity to every component in a safe manner where all of the electrical codes are followed. Some familiar electrical engineering tasks may be found in the lighting design, regulating the voltage and distributing the electricity to each and every component of building which needs a supply.

plumbing, there is certainly a wide array of plumbing components that constitute the final design of any building. Plumbing engineering goes deeper than simply faucets, toilets, and sinks, and holds several behind the scene devices. These being the sewage and drainage lines and also the buildings local water supply and just how it flows.

As we wrap up our article we certainly have just considered what is MEP Engineering. MEP Engineering is administered in the construction industry. And, helps with completing the simply overlooked technical facets of any building.

Hiring an MEP Engineering Firm in Ashburn Estates Chicago is Important for Major Construction Projects

Hiring an MEP engineering firm in Scottsdale Chicago, ILO, can have a whole lot to do with the achievements of your construction project. These pros can help offset the expense of making such a hiring decision in relation to energy saving alone. If you are speaking about big commercial structures, energy saving is a vital topic of discussion. It’s time to find out some other great factors behind employing MEP engineering company in Edgewater Chicago, IL.

Engineers have a lot to do with the physical reliability of the building. As you may well imagine, this means the hidden is very important. Design not just deals in looks but the base of a building and its workings. Which is yet another solid logic why using an MEP engineering company is going to be good for your project.

Consider every one of the pipes and plumbing. Take into account the air conditioning systems and how important it is to get each one of its components in the right places. Energy maintenance was discussed, but energy competence is an additional important term to speak of. Energy competence is about your HVAC system, and it plays a huge role in energy conservation in general.

Think of your building’s shell. Consider setting up fire alarm systems as well as the security and safety measures set up throughout the structure. With everything mentioned so far, it’s safe to say that numerous aspects of building construction may be either disregarded or underestimated without MEP engineers on-the-job.

Now with this info you are going to be looking for the very best MEP engineering firm in the industry, right? It’s pretty clear that the best engineers must be working in the massive building of commercial structures. Personalized is definitely the best term to utilize to clarify the way in which these engineers will covert a construction project to meet the requirements of your operations. Even with all of this information you would like additional information on the MEP Engineering services in Ashburn Estates Chicago, IL by New York Engineers you should check out at our blog.

Value Engineering Related Blog Post

Selecting the Right Type of Electrical Raceway for your Architectural Engineering Project: Nonmetallic Conduit Options

Fire Protection Engineering Magazine

Our previous article covered the main types of metallic conduit for electrical conductors, and now we will discuss nonmetallic conduit and its applications in architectural engineering and other engineering areas. Nonmetallic conduit is normally the more affordable option, providing improved electrical isolation and corrosion resistance, while reducing the degree of physical protection.

Like with metallic conduit, all electrical installations must be according to the NFPA National Electric Code and local electrical codes. Conductors are not intended for unprotected installation, except for specific types that include metallic armor or polymer sheathing.

Keep in mind that this article is no replacement for electrical codes; the technical information provided here is very general. When working with engineering projects that involve electrical installations, you should check the specific code requirements for each application.

Rigid Polyvinyl Chloride Conduit (PVC)

PVC is possibly the most common type of nonmetallic conduit used in architectural engineering projects, being lightweight and affordable, while offering decent mechanical resistance for its low weight. In addition, it is virtually unaffected by humidity and corrosion, and is also an electrical insulator. However, the insulating properties of PVC are both a benefit and a disadvantage: the conduit itself cannot be electrified, but a grounding conductor becomes mandatory as a result, while metallic conduit can be used as both raceway and grounding in various applications.

PVC also offers features that simplify installation: it can be heated for quick manual bends, recovering its rigidity once it cools down. In addition, its low weight simplifies handling, and the conduit is easy to cut. PVC fittings are unthreaded and designed for slip-on installation, using solvent cements. PVC pull boxes also bring the reduced weight advantage, making them easier to handle and install.

This type of nonmetallic conduit is available with three different wall thicknesses: Schedule 20 is the thinnest, Schedule 40 is intermediate, and Schedule 80 is the thickest. Trade sizes range from ½” to 6”.

  • Schedule 20 PVC, with its thin walls, is not approved by the NEC for electrical installations. Therefore, it is used mostly in communication systems.
  • Schedule 40 PVC is the general-purpose option, adapting to a wide range of applications.
  • Schedule 80 PVC is used there conduit is exposed to physical damage. It is more expensive than Schedule 40, but its added strength increases the allowed applications.

The use of PVC conduit is not allowed in hazardous locations, areas where the ambient temperature exceeds 50°C (122°F), or applications where conductor insulation temperature exceeds the rated temperature of PVC. When used for lighting circuits, PVC cannot be used as physical support to hang lighting fixtures. Although the code does not prohibit its use with low ambient temperatures, consider that extreme cold can make PVC brittle, offering reduced protection for conductors.

High Density Polyethylene Conduit (HDPE)

HDPE is a type of nonmetallic conduit for applications where the circuit is buried or encased in concrete. It is not approved for indoor use or for exposed installation. Like PVC conduit, HDPE is not allowed in hazardous locations unless the code makes a direct exception, and it subject to the same ambient temperature and conductor insulation temperature limitations. The approved HDPE trade sizes range from ½” to 6”.

Reinforced Thermosetting Resin Conduit (RTRC)

RTRC is more commonly known as fiberglass conduit. Its applications are very similar to those of Schedule 40 PVC, but there is one key advantage: PVC can become brittle when exposed to very cold weather, while RTRC conserves its mechanical properties. RTRC is suitable for exposed or buried installation, indoor or outdoor use, and is unaffected by humidity and corrosion.

The applications where RTRC is not allowed are similar to those of Schedule 40 PVC: hazardous locations, luminaire support, and areas where it is exposed to physical damage or high temperature. Like with PVC and HDPE, trade sizes range from ½” to 6”.

Liquidtight Flexible Nonmetallic Conduit (LFNC)

LFNC has a self-explanatory name: it is a type of nonmetallic conduit intended for connections and cable runs with obstacles that are difficult to bypass with rigid conduit. LFNC is a versatile option, approved for various indoor and outdoor applications. Usage is not allowed where it will be exposed to damage, in hazardous locations, or if temperatures exceed conduit ratings. Like PVC, LFNC is vulnerable to extreme cold: it may become brittle, losing its flexibility. Unless codes make an exception, LFNC should not be used in runs longer than 6 ft or with circuits above 600V. Approved trade sizes range from ⅜” to 4”.

Electrical Nonmetallic Tubing (ENT)

ENT has similar applications to LFNC, but can be used for runs longer than 6 feet. In indoor locations, ENT can be either exposed or concealed. It resists moisture and corrosion, but can only be used outdoors if encased in concrete or protected from sunlight. Direct burial is not allowed, and it can only be installed exposed to the sun if specified as sunlight resistant.

ENT trade sizes range from ½” to 1”, and it is subject to the same usage restrictions that apply for many other types of nonmetallic conduit: hazardous locations, high temperatures and luminaire support.

Additional Recommendations from an Architectural Engineering Professional

Although each application is unique, non-metallic conduit generally offers a cost advantage over metallic conduit, giving up on some physical protection. However, keep in mind that metallic conduit may be mandatory in various architectural engineering applications; for example, the most demanding environments typically require rigid metal conduit (RMC) or intermediate metal conduit (IMC).

To achieve the best results in electrical installations, working with qualified professionals is highly recommended. In new construction, you can achieve drastic cost reductions with smart design decisions. For example, energy efficiency reduces the electrical load, which in turn reduces conductor and conduit diameter.

Popular searches related to Engineering Reports in Ashburn Estates Chicago, Illinois.

Construction Engineering Courses

(MEP) Engineering Service in Ashburn Estates Chicago

MEP Company Ashburn Estates Chicago! When you're looking for a dependable MEP Firms in Chicago? The top choice is is NY Engineers. Not only for MEP Engineering in Chicago but also Value Engineering and Sprinkler Engineering throughout Ashburn Estates Chicago. Call (+1) 312 767-6877 A large group of construction companies throughout Kiryas Joel, New York have come to rely on NY Engineers for a wide range of engineering services ranging from [...]

2018-08-25T01:53:59+00:00