MEP Service in Beverly View Chicago, IL.

Contact Us

In search of the best MEP Firms in Chicago? The one to go to is NY Engineers. Not only for MEP Engineering in Chicago but also Value Engineering and Sprinkler Engineering in or near Beverly View Chicago. Call us at (312) 767-6877

Contact Us
HVAC Engineering

Real estate investors throughout Central Islip, NY have come to depend on New York Engineers for a wide range of engineering services ranging from Plumbing Engineering to Engineering Reports. For this reason building owners in Beverly View Chicago will tell you that if you’re looking for a excellent MEP Engineering firm in Beverly View Chicago, IL you should consider New York Engineers.

Odds are, you have walked into any specific type of building and saw the outcome of MEP Engineering. In other words, MEP focuses on the mechanical, electrical and plumbing elements of engineering. Essentially, the name already gives rise to the most common and precise guess of precisely what is MEP. Our article may go into some specifics of what is MEP Engineering.

As far as the mechanical aspect is involved, for commercial and residential engineering, this relates to anything which moves. Moreover its entails the usage of complex and easy machines as well as other mechanical mechanisms to do certain tasks. Some ordinary mechanical engineering jobs that may be noticed daily are HVAC units, kitchen or bath exhausts, cooling and heating air systems and equipment and systems that take care of improving the energy efficiency.

The electrical aspect of construction is focused on the components, functions, electrical safety, and most importantly, the wiring of the building. Engineers in this particular unit go to great lengths to ensure that the layout of the building are designed to bring enough power to every individual component in a safe manner ensuring that all of the electrical codes are followed. Some common electrical engineering functions are available in the lighting design, modifying the voltage and distributing the electricity to every single component of building that takes a supply.

As far as plumbing, there is certainly a variety of plumbing factors that constitute the final design of any structure. Plumbing engineering goes deeper than just faucets, toilets, and sinks, and houses several behind the scene equipments. These being the sewage and drainage lines along with the buildings local water supply and how it flows.

As we wrap up our article we have now just considered what is MEP Engineering. MEP Engineering is managed in the construction industry. And, helps with completing the often unnoticed technical areas of any building.

Hiring an MEP Engineering Firm in Beverly View Chicago is Essential for Huge Construction Projects

Hiring an MEP engineering firm in Edison Park Chicago, ILO, might have everything to do with the prosperity of your construction project. These pros might help offset the fee for making this sort of hiring decision with regards to energy management alone. While you are speaking about huge commercial structures, energy conservation is really a topic of discussion. It’s time to determine various other great factors behind using MEP firm in Norwood Park East Chicago, Illinois.

Engineers have a lot to do with the structural reliability of any building. If you can well imagine, it means the hidden is extreamly essential. Design not merely deals in looks but the base of a building including its workings. That may be yet another solid good reason that using an MEP engineering company will probably be beneficial to any project.

Take into consideration all the pipes and plumbing. Take into account the heating and cooling systems and the importance of getting all its components in the correct places. Energy maintenance was mentioned, but energy efficiency is an additional vital term to mention. Energy efficiency is about your HVAC system, and it plays a vital part in energy conservation as a whole.

Take into consideration your building’s footing. Consider installing fire alarm systems along with the security and safety measures set up through the entire structure. With everything discussed thus far, it’s reliable advice that a great many facets of building construction might be either ignored or underestimated without MEP engineers on the job.

Now with all you have read you will look to find the best MEP engineering firm in the industry, right? It’s very clear how the best engineers need to be active in the massive construction of commercial structures. Personalized is definitely the proper term to use to illustrate how these specilists will adapt a construction job to meet the needs of the operations. Even with all of this information you would like more info about the MEP Engineering services in Beverly View Chicago, IL by New York Engineers you should visit at our blog.

Sprinkler Engineering Related Article

Electrical Safety and Power Quality: A Short Guide for Electrical Engineering

Electricity is one of the cornerstones of modern society, but it can be very dangerous if handled incorrectly. Therefore, governments have introduced stringent codes to regulate its use and ensure safety for occupants. A building’s power supply must be safe to use, and it must also have the voltage and frequency required by the electrical appliances in the building. The electrical engineering systems that provide electrical safety and power quality are typically hidden from sight, but they play a fundamental role in buildings.

Electrical issues are more common in pre-war apartment buildings and other old constructions. Always make sure you get the installation checked before moving into an existing property, but especially if it very aged.

Electrical Protection Devices

The main function of electrical protections is to disconnect the power supply when dangerous operating conditions are present. The main types of electrical faults found in electrical engineering systems are the following:

  • Overload or overcurrent
  • Short circuit
  • Ground fault
  • Line-to-line fault
  • Transient or voltage surge

Plug-in circuit breakers are perhaps the best-known electrical protection devices, commonly used in residential and light commercial applications (below 100 Amperes). Molded-case circuit breakers are generally larger and reach higher current ratings, while motor circuit protectors and thermal overload relays are designed for the protection needs of electric motors. Other than the plug-in configuration, there are protection devices designed for a DIN rail mount or for bolted connections.

An overload occurs when an electrical circuit is drawing current above its rated value for an excessively long period. It is important to note that short-duration overcurrent is common in some types of equipment. For example, three-phase electric motors may draw up to eight times their rated current during startup, but only for a short time – typically fractions of a second. Some types of lighting also draw an inrush current, especially if they have ballasts.

Circuit breakers typically use a thermal interruption mechanism to protect circuits from overload while allowing short-duration current peaks. The thermal protection mechanism uses a metallic contact that expands when heated by current, and it is calibrated to allow the circuit breaker’s rated current but not higher values. However, since inrush currents occur too quickly, their heating effect is not enough to expand and disconnect the thermal protection mechanism. On the other hand, an overload eventually trips the breaker; as current magnitude increases, the thermal protection contact expands faster and disconnects the circuit in less time.

A short circuit occurs when a live conductor touches a neutral conductor, causing a very high current. The magnitude of a short circuit fault is very high, typically thousands of amperes, so it must be disconnected as quickly as possible. In this case the response of thermal protection is too slow, so the protection mechanisms that clear short circuit faults are based on electromagnetic induction – the intense current induces a strong magnetic field that disconnects the circuit breaker.

A ground fault, also known as a line-to-ground fault, occurs when a live conductor touches a conductive element that is not part of the electric circuit. This also creates a very high current due to the low contact resistance, activating the magnetic protection mechanism of the respective circuit breaker. A line-to-line fault occurs when two live conductors at different voltage touch each other, also causing a high-magnitude current. In both cases, the same magnetic protection mechanism that clears short circuit faults responds and trips the circuit breaker.

All the faults described above are characterized by excessive current. When a high voltage peak occurs, the fault is called a transient or a voltage surge. Voltage surges normally occur when large equipment is switched, and can also be caused by lightning. Since circuit breakers are not designed to protect installations from voltage surges, you must use a surge protection devices (SPD) or transient voltage surge suppressor (TVSS). One of the most common types of TVSS use a variable resistance (varistor) connected between the live conductors and the ground – its resistance is high under normal operating conditions, but drops to a very low value in response to voltage peaks, discharging the fault to the ground before it reaches sensitive equipment.

Improving Power Quality in Electrical Engineering Systems

Electric power systems may also suffer from issues that are not faults strictly speaking, but which are also detrimental for performance. Two of the main issues are low power factor and harmonics.

Power factor is a very abstract concept, but the following is a simple way to visualize it. Some types of electrical equipment draw current in such a way where not all the power drawn from the voltage supply is really consumed. In these cases, the term “real power” is used to describe the power that is actually used, and the term “reactive power” is used to describe the portion that oscillates back and forth between the equipment and the power supply without being used. Some of the most common loads associated with reactive power are electric motors, transformers and ballasts. The power factor is the ratio of the real power used and the apparent power – the direct multiplication product of voltage and current.

  • Assume a single-phase motor consumes 900 W of electric power while drawing 5 amperes at 240 volts.
  • The apparent power is 1,200 volt-amperes (240V x 5A).
  • The power factor is 0.75 (900W / 1200 VA). It can also be reported as 75%.
  • The maximum possible value is 1.00 or 100%, where all the power drawn from the voltage source is consumed. Purely resistive loads such as incandescent lamps and resistance heaters behave this way.

Low power factor increases the current drawn by a building, and this creates an extra burden for the grid. Therefore, utility companies typically penalize users that allow their power factor to drop below a specified value. Low power factor is corrected by installing capacitors, which are similar to batteries but designed for a much faster cycle – the oscillating current that characterizes reactive power is supplied locally by the capacitor, and not drawn from the power grid, sparing the user from extra charges.

Power factor correction is characterized by its quick payback period, typically less than one year.

Harmonics are voltage and current signals whose frequency is a multiple of the service frequency – 60 Hz in the USA. Harmonics are produced by nonlinear loads such as magnetic cores and digital equipment, and they tend to overheat circuits, especially the neutral conductor. Excessive harmonics can also cause some types of electronic equipment to malfunction. Harmonic filters are devices that are tuned for a specific harmonic frequency, and when installed in a power system they prevent the propagation of harmonics beyond the equipment that generates them.

Conclusion

The best recommendation to keep all these electrical issues under control is to seek professional assistance from an electrical engineering profession. In new constructions, protection and power quality can be addressed from the design stage. For existing buildings, power monitoring equipment can be used to detect harmonics or low power factor, and the measurement results are then used to specify harmonic filters and capacitors. If circuit breakers are tripping frequently, get an inspection to determine the cause: there could be an electrical fault, but the breaker itself could also be damaged.

searches related to Construction Administration Beverly View Chicago, IL.

Fire Protection Engineering UMD

(MEP) Engineering Service in Beverly View Chicago

MEP Firm Beverly View Chicago! When you re searching for a reliable MEP Engineering in Chicago? The top choice is is NY Engineers. Not only for MEP Firms in Chicago but also Electrical Engineering and Sprinkler Engineering in Beverly View Chicago. Call (+1) (312) 767-6877 Several general contractors throughout Schenectady, New York have come to rely on NY Engineers for a wide range of engineering services ranging from MEP Engineering to [...]