MEP Service in Bolingbrook, IL.

Contact Us

Searching for a top MEP Chicago? The one to go to is New York Engineers. Not only for MEP Firms in Chicago but also HVAC Engineering and Protection Engineering in Bolingbrook. Call (312) 767-6877

Contact Us
Fire Protection Engineering

Property owners throughout Deer Park, New York have come to depend on NY-Engineers.Com for a wide range of engineering services ranging from MEP Engineering to Building Commissioning. That is why property owners in Bolingbrook will tell you that if you are looking for a excellent MEP Engineering firm in Bolingbrook, Illinois you need to consider NY Engineers.

No doubt, you may have walked through any particular kind of building and seen the outcomes of MEP Engineering. In other words, MEP centers around the mechanical, electrical and plumbing facets of engineering. In simple terms, MEP already gives rise to the most frequent and correct assumption of precisely what is MEP. This article will go into some specifics of what is MEP Engineering.

As far as the mechanical aspect is involved, for commercial and residential engineering, this works with anything which moves. Furthermore its entails the use of complex and uncomplicated machines together with other mechanical mechanisms to execute certain tasks. Some everyday mechanical engineering tasks that can be noticed everyday are HVAC units, kitchen or bath exhausts, cooling and heating air systems and equipment and systems which deal with increasing the energy efficiency.

The electrical aspect of construction is focused on the electrical safety, functions, components, and even more importantly, the wiring of the building. Engineers with this sector go to great lengths to ensure the layout of a building are made to supply adequate power to every component in a safe manner ensuring that every one of the electrical codes are followed. Some commonplace electrical engineering jobs can be obtained from the lighting design, modifying the voltage and allocating the power to every component within the building which needs a supply.

In terms of plumbing, there exists a variety of plumbing factors which constitute the final style of any structure. Plumbing engineering goes deeper than just faucets, toilets, and sinks, and holds many behind the scene devices. These being the sewage and drainage lines along with the buildings local water supply and just how it flows.

As we conclude this article we have just reviewed what is MEP Engineering. MEP Engineering is managed in the construction industry. And, assists in completing the simply overlooked technical facets of any building.

Hiring an MEP Engineering Firm in Bolingbrook is Essential for Huge Construction Projects

Hiring an MEP firm in Longwood Manor Chicago, Illinois, could have everything to do with the achievements of your construction project. These engineers can help offset the cost of making this kind of hiring decision in relation to energy conservation alone. If you are speaking about large commercial structures, energy saving is a vital topic of discussion. It’s time to learn various other great reasons for using MEP engineering company in Merchant Park Chicago, IL.

Engineers have everything to do with the structural reliability of a building. As you may well imagine, this means the unseen is very essential. Design not just deals in looks but the foundation of a building and its workings. That is certainly yet another solid good reason that using an MEP engineering company will be beneficial to any project.

Think of all of the pipes and plumbing. Consider the heating and cooling systems and the importance of getting each one of its mechanics in the correct places. Energy saving was mentioned, and energy competence can be another significant term to note. Energy efficiency is about your HVAC system, and it plays a vital part in energy saving overall.

Take into consideration your building’s footing. Consider the installation of home security systems along with the safety and security measures set up through the structure. With everything else described thus far, it’s safe to say that numerous facets of building construction might be either overlooked or minimized without MEP professionals on the job.

Now with all you know you are going to look for the very best MEP engineering firm in the industry, right? It is very obvious the best engineers must be working in the large building of commercial structures. Personalized will be the best term to make use of to describe the way in which these experts will customize a construction project to meet the needs of the operations. There is only so much you can save this page if you would like more info about the MEP Engineering services in Bolingbrook, IL by NY Engineers you should stop by at our blog.

Fire Protection Engineering Related Blog Post

Mechanical Engineering Design Options to Heat and Cool Residential Buildings

Architectural Engineering Courses

There is a broad range of mechanical engineering and design options available for meeting the heating and cooling needs of residential buildings. Normally, these systems differ in terms of the medium used to deliver their heating or cooling output.

  • Water Piping: Water source heat pumps, radiators using chillers, cooling towers, and boilers.
  • Air Ducts: Packaged rooftop units, packaged ceiling hung units
  • Refrigerant Lines: Split AC systems, VRF systems
  • Direct: Used by window-type air conditioners and PTAC units, which operatedirectly between indoor and outdoor locations, without ducts.

This article will provide an overview of some of the most common mechanical design options used for indoor residential spaces, as well as the strengths and limitations of each type of system:

Detailing Mechanical Engineering and Design Options

Mechanical Design Option #1: Four-Pipe System with Chiller, Cooling Tower, and Boiler

This mechanical design gets its name from the fact that it has two separate water circuits, one carrying hot water and another carrying chilled water, each with a supply and return pipe. The basic operating principle of four-pipe systems is the following:

  • Cooling is accomplished by a chiller and cooling tower: A chilled water circuit is used to remove heat from indoor spaces, and the cooling tower is used to reject it outdoors. If the chiller’s compressor comes equipped with a variable-speed drive, this system can offer a very high efficiency in cooling mode.
  • Heating efficiency is determined by the type of boiler. In general, gas-fired boilerstend to be more cost-effective than those running on oil or electrical resistance heating.
  • Fan-coil units are equipped with both hot and cold water coils, granting them the flexibility of either mode of operation.

The main advantage of four-pipe systems is their ability to use both modes of operation simultaneously and independently. This can be especially useful if heating and cooling needs are different across building zones, and especially in apartment buildings and multi-family dwellings where preferences and schedules normally vary by occupant. Of course, a four-pipe system is an expensive mechanical engineering system to install due to the presence of three separate water circuits: two for the distribution of cold and hot water, and a third one used by the chiller to reject heat through the cooling tower.

Mechanical Design Option #2: Water-Source Heat Pumps with Cooling Tower and Boiler

A heat pump can be described in simple terms as a reversible air conditioner: it can deliver indoor cooling through the refrigeration cycle, but can also operate in heating mode with a much higher efficiency than most types of boilers, especially electrical resistance boilers.

Due to their reversible operation, water-source heat pumps offer great flexibility in residential buildings. Individual units can be set to operate in different modes, and in combined heating and cooling applications the overall system can be extremely efficient:

  • Heat pumps in cooling mode extract heat from indoor spaces and release it into a common water circuit.
  • Then, heat pumps in heating mode can extract the heat now carried by the water, and release it indoors, as required.

The fact that heat pumps share the same water circuit means that the cooling tower and boiler only have to balance system loads, rather than meeting them fully:

  • If the cooling load is greater than the heating load, the cooling tower only has to reject the heat difference, not the total heat removed from all spaces.
  • The same logic applies if the heating load is higher than the cooling load: the boiler only has to make up for the difference, not the full heating load.
  • If the heating and cooling loads happen to balance each other out, both the cooling tower and boiler can remain off.

A four-pipe system lacks these capabilities: the chiller must assume the full cooling load while the boiler provides the full heating load – all the heat absorbed in the chilled water loop is rejected by the cooling tower, and can’t be used for space heating purposes because water circuits are independent.

HVAC systems based on water-source heat pumps are extremely efficient, although expensive due to the fact that every zone must be equipped with an individual heat pump, in addition to having a common water circuit, a cooling tower, and a boiler.

Mechanical Design Option #3: VRF System with Rooftop Condensers & Gas Boiler

VRF stands for variable refrigerant flow, and VRF systems get their name from the fact that refrigerant is used to transport heat instead of water:

  • One or more remotely located condensers provide a flow of refrigerant for multiple indoor fan-coils, and a variable speed drive is used to regulate flow according to load. The units can also provide their own heating.
  • For supplementary heating, a gas-fired boiler with perimeter radiation can be added to the system.
  • Two-pipe VRF systems require all fan-coils to operate in the same mode, but with three-pipe systems, it is possible to provide simultaneous heating and cooling for different areas of the building.

Other than operational flexibility, an advantage of this mechanical design option is their ease of installation: refrigerant lines are more compact than water piping and air ducts. These systems still have a relatively small market share in the USA, but are very common in Japan, where they were developed, and Europe. According to ASHRAE, VRF systems tend to have a comparable cost to that of chiller-based systems, potentially higher if the technology must be imported.

The modular nature of VRF systems is another strong point in favor of this technology. If there will be a building expansion, it is possible to expand the system by simply adding a new condenser and the corresponding indoor evaporators.

Mechanical Design Option #4: PTAC Units with Electric Resistance Heating

Packaged terminal air conditioning units (PTAC) are compact systems, very similar to old window-type air conditioners: the system is self-contained and does not require refrigerant lines, water piping, or air ducts, greatly reducing the installed cost. Some PTAC units are equipped with a resistance heater, allowing them to operate in both heating and cooling modes.

PTAC units offer the advantage of being self-contained and independent from each other. This gives them an advantage in projects that will be built in several stages, for example, apartment buildings, since it is possible to expand HVAC capacity as needed without having a common system on which all units depend.

The main limitation of this mechanical system is that they tend to be outclassed by other systems in terms of efficiency, especially when in heating mode. Resistance heating offers a coefficient of performance of 1.0, which means they must draw one watt of electricity per each watt of heating; on the other hand, heat pumps typically operate with a COP of 2.5 or more, or even above 4.0 if a high-efficiency heat pump is selected.

Concluding Remarks

There is a broad range of heating and cooling technologies available for residential buildings, and also a high degree of flexibility in how the overall system can be configured. No system can be considered superior to the rest under all circumstances – every project offers unique conditions that favor some technologies over others.

What kind of mechanical engineering design has worked the best for you? Let us know by commenting below.

Common searches related to MEP Engineering Bolingbrook, Illinois.

Construction Engineering Vs Civil Engineering

(MEP) Engineering Service in Bolingbrook

MEP Firm Bolingbrook! If you re looking for a competent MEP Chicago in Firm? Your best bet is to contact is NY-Engineers.Com. Not only for MEP Firms in Chicago but also Electrical Engineering and Sprinkler Engineering throughout Bolingbrook. Contact us at (312) 767-6877 Many construction companies throughout Oceanside, New York have come to depend on New York Engineers for a wide range of engineering services ranging from Electrical Engineering to Value [...]

2018-09-16T04:30:13+00:00