MEP Service in Darien, IL.

Contact Us

Searching for the top MEP Chicago? Your best bet is to reach out to is NY Engineers. Not only for MEP Chicago but also Electrical Engineering and Sprinkler Engineering throughout Darien. Contact us at (+1) 312 767-6877

Contact Us
HVAC Engineer Career Path

Building owners throughout Mamaroneck, NY have come to depend on New York Engineers for a wide range of engineering services ranging from Mechanical Engineering to Utility Filings. This is why construction companies in Darien will tell you that if you’re searching for a dependable MEP Engineering firm in Darien, Illinois you should consider NY-Engineers.Com.

It is very possible, you have walked into any specific sort of building and saw the outcome of MEP Engineering. Simply put, MEP focuses on the mechanical, electrical and plumbing aspects of engineering. In simple terms, the name already gives rise to the most common and accurate assumption of what exactly is MEP. Our article will go into some infor of what is MEP Engineering.

So far as the mechanical part is concerned, for both residential and commercial engineering, this works with anything which moves. Additionally its involves the usage of complex and easy machines and also other mechanical mechanisms to perform certain tasks. Some ordinary mechanical engineering jobs which can be noticed regularly are HVAC units, kitchen or bath exhausts, cooling and heating air systems and equipment and systems that handle improving the energy productivity.

The electrical aspect of construction is focused on the components, functions, electrical safety, and even more importantly, the wiring of any building. Engineers in this sector try very hard to ensure the schematics of your building are designed to bring ample electricity to each individual component in a safe manner ensuring that all of the electrical codes are met. Some familiar electrical engineering functions are available in the lighting design, modifying the voltage and distributing the power to each component in the structure which takes a supply.

With regards to plumbing, there is a wide array of plumbing factors which make up the final style of any building. Plumbing engineering goes deeper than just faucets, toilets, and sinks, and holds many behind the scene devices. These being the drainage line and sewage as well as the buildings domestic water supply and just how it flows.

As we wrap up our article we certainly have just looked at what is MEP Engineering. MEP Engineering is administered throughout the construction industry. And, assists in completing the often ignored technical facets of any building.

Hiring an MEP Engineering Firm in Darien is Important for Huge Construction Projects

Hiring an MEP engineering firm in New City Chicago, ILO, can have everything to do with the safety of your construction project. These experts will help offset the expense of making this sort of hiring decision when it comes to energy upkeep alone. If you are talking about large commercial buildings, energy upkeep is an important topic of discussion. It’s time to find out some other great factors behind using MEP engineering firm in Belmont Gardens Chicago, Illinois.

Engineers have a great deal to do with the structural reliability of the building. As you can well imagine, that means the hidden is very important. Design not only deals in looks but the basis of a building and its workings. Which is the next solid logic why hiring an MEP engineering firm will likely be useful to any project.

Consider every one of the pipes and plumbing. Look at the heating and cooling systems and how important it is to get all of its components in the exact places. Energy saving was mentioned, and energy competence is yet another important term to mention. Energy competence is related to your HVAC system, plus it plays a huge role in energy conservation overall.

Think about your building’s base. Consider installing security systems and also the security and safety measures set up through the entire structure. With everything described thus far, it’s safe to say that a great many aspects of building construction might be either ignored or underestimated without MEP pros on the job.

Now with this info you will look for the best MEP engineering firm in the industry, right? It is very obvious that this best engineers need to be active in the large building of commercial structures. Tailor made is the best term to make use of to clarify the way these experts will customize a construction job to meet the requirements of the operations. There is only so much you can save this page if you would like more information about the MEP Engineering services in Darien, Illinois by NY-Engineers.Com we invite you to visit at our Darien Plumbing Engineering blog.

New MEP Engineering Related Blog

An MEP Engineers’ Guide to Air Dampers

Mechanical Engineering Salary

An air damper is a device that uses valves or plates to stop or regulate the flow of air within a duct, chimney, variable-air-volume (VAV) box, air-handling unit or other similar pieces of equipment. Dampers are also used to stop airflow into unoccupied or unused rooms where air conditioning is not required. In addition, MEP engineers install dampers as protection measures against smoke or fire.

An air damper is a complex mechanism with many moving elements. Their main components are the blades, which adjust their position to control airflow. In addition, dampers include frames, linkages, axles, bearings, seals, blade pins, actuating motors, flanging, jackshafts, and sleeves, among other components.

Types of Air Dampers

Based on their construction, air dampers can be classified into parallel blade and opposed blade dampers. Each configuration has unique performance features and is intended for different applications.

1) Parallel Blade Dampers

In this type of air damper, blades rotate in the same direction, parallel to one another. The parallel blade configuration is typically used when the damper operates in two positions: open or closed.

These dampers redirect air flow along their first few degrees of rotation, as they move from fully open to closed, and therefore control is achieved along the first 20-30% of movement.  Rather than modulating air streams, these dampers change their direction, and that is the main reason why they are preferred for open-close operation or fixed flow control.

Parallel blade dampers are typically used by MEP engineers in applications where the damper represents a major portion of the overall system pressure loss. They should not be used upstream of critical components due to their uneven airflow.

2) Opposed Blade Dampers

In this type of air damper, blades rotate in opposite directions to one another, modulating airflow. These air dampers are mostly used when the system requires airflow control rather than open-close operation, but they can also be used for on-off service.

Opposed blade dampers are typically used in the following applications:

  1. When the damper doesn’t represent a major portion of the overall system pressure loss.
  2. Systems that are required to maintain an even airflow downstream from the damper.
  3. Ducted terminals.

Classification of Dampers by Control Method and Application

Air dampers can also be classified based on the control method they deploy and their intended application. Based on their control method, dampers can be either automatic or manual:

  • Automatic dampers are similar to automatic control valves in terms of functioning.
  • Manual dampers are adjusted manually depending on the required airflow, as implied by their name.

Dampers can also be classified based on their application, and the following are some of the main types:

  • Balancing dampers (volume dampers)
  • Face and bypass dampers
  • Fire dampers
  • Smoke dampers
  • Combined fire and smoke dampers
  • Gravity dampers (backdraft or barometric)
  • Mixing dampers
  • Multi-zone dampers
  • Round dampers
  • VAV boxes (variable-air-volume)

Note how dampers are not only used for air balancing in ventilation systems, but also for safety in fire protection applications.

Why Are MEP Engineers Concerned About Dampers?

Air dampers are an important element of MEP engineering design since their use is subject to code requirements. They should also be designed to minimize energy losses, through the prevention of heat exchange across them when in the closed position, all while maintaining the required pressure conditions in different spaces.

Air dampers are subject to the following codes and standards:

  1. National Fire Protection Association (NFPA) standards:
    1. NFPA 90A Standard for the Installation of Air-Conditioning and Ventilating Systems
    2. NFPA 92A Standard for Smoke-Control Systems Utilizing Barriers and Pressure Differences
    3. NFPA 101 Life Safety Code
  2. Underwriters Laboratories (UL) standards:
    1. UL 555 Standard for Fire Dampers
    2. UL 555S Standard for Smoke Dampers
    3. UL 555C Standard for Ceiling Dampers

The main locations where air dampers are required to meet code are the following: stair enclosures, elevator shafts, common corridors, mechanical rooms, fire-rated walls, exterior building walls, shaft enclosures, horizontal assemblies, and duct and transfer openings.

Air Dampers in Fire Protection Applications

The three main types of dampers used in fire protection applications are fire dampers, smoke dampers, and combined fire/smoke dampers. This section provides an overview of each type and its applications.

Fire Dampers

Fire dampers interrupt airflow through the duct automatically, restricting the passage of flames. To accomplish their function, these dampers are installed in ducts that cross fire-rated assemblies or fire-rated walls. They can be installed in both horizontal and vertical ductwork and can be of both curtain type and multi-blade type.

A fire damper has the following components:

  1. Sleeve
  2. Curtain blade
  3. Break-away joints
  4. Fusible link
  5. Access door to inspect the fire damper

All fire dampers are installed in the open position, with a fusible link. When the temperature in the ductwork exceeds a specified value, the fusible link melts and the damper gets shut off, either by gravity or by a spring. To guarantee they accomplish their function, fire dampers need to pass various tests.

Fire damper selection is based on three main factors: fire resistance rating, temperature, and operating range. Fire rating depends on the time span for which a damper will withstand the heat associated with a fire. For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire dampers are used. This procedure ensures building code compliance, which requires that the fire resistance rating is maintained across the full area of walls, partitions, and floors.

The exceptions for the use of fire dampers are parking garages, kitchen exhaust ductwork, and dryer exhaust ductwork.

Smoke Dampers

Smoke dampers prevent smoke from spreading in HVAC systems that are designed to shut down automatically in case of fire, and they only have two positions: open and closed. These dampers are installed in a slotted duct section – they are installed whenever a duct penetrates a smoke partition or smoke barrier inside the building. They can be applied in passive smoke control systems, or as part of an engineered smoke control solution.

In passive systems, smoke dampers close and prevent the circulation of air and smoke through ducts or ventilation openings that cross a smoke barrier. On the other hand, in engineered smoke control systems, the spread of smoke is controlled by the building HVAC system or by dedicated fans that create pressure differences. Smoke dampers may be controlled by heat sensors, smoke sensors, fire alarms, or any other method that meets the design intent.

A smoke damper has the following components:

  1. Sleeve
  2. Smoke blades (parallel)
  3. Break-away joints
  4. Duct-mounted smoke detector
  5. Damper actuator
  6. Access door

It is important to decide which ratings are required for UL Listed fire dampers.

  • The SD-1320 and SD-1330 smoke dampers are UL/cUL leakage rated dampers, listed under the latest UL 555S standard.
  • SD-1620 smoke dampers meet UL Class II. Leakage is less than 20 cfm per square foot at 4 inch w.g. and at 350°F (177°C).
  • SD-1630 smoke dampers meet UL Class I. Leakage is less than 8 cfm per square foot at 4 inch w.g. and at 350°F (177°C).

Fire and Smoke Damper (Combined)

As implied by its name, this type of damper is a combination of a fire damper and a smoke damper, and it is installed in ducts that cross partitions rated as both fire and smoke barriers. This type of damper must be qualified under both UL555 and UL555S.

Selection of a combined fire and smoke damper depends upon 4 factors: fire resistance rating, leakage rating, temperature and operational ratings.

Combined fire and smoke damper applications include walls, floors, partitions required by the local building code.

For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire/smoke dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire/smoke dampers are used. Designers are usually suggested to pick a very low leakage category.

Conclusion

Air dampers have a wide range of applications, ranging from airflow modulation in normal operating conditions to providing a reliable barrier against smoke or fire during emergencies. However, code compliance is an important aspect to consider regardless of the application, so working with qualified MEP engineers is highly recommended.

Top searches related to CAD to Revit Modeling in Darien, Illinois.

Electrical Engineering Basics

(MEP) Engineering Service in Darien

MEP Firm Darien! If you re searching for a dependable MEP Chicago in Firm? The one to go to is is New York Engineers. Not only for MEP Engineering in Chicago but also HVAC Engineering and Sprinkler System Engineering in Darien. Call (+1) (312) 767-6877 Several building owners throughout Lynbrook, New York have come to rely on NY Engineers for a wide range of engineering services ranging from Fire Protection Engineering [...]