MEP Engineering Services in Kennedy Park Chicago, Illinois.

Architectural Engineers

Construction companies throughout New York have come to rely on NY Engineers for a wide range of engineering services ranging from Electrical Engineering to Construction Administration. That is why real estate investors in Kennedy Park Chicago will tell you that if you are looking for a dependable MEP Engineering firm in Kennedy Park Chicago, IL you need to consider NY-Engineers.Com.

Odds are, you might have walked through any particular type of building and observed the outcomes of MEP Engineering. Basically, MEP focuses on the mechanical, electrical and plumbing aspects of engineering. Essentially, the name already gives a clue to the most frequent and correct assumption of what is MEP. Our article may go into some specifics of what is MEP Engineering.

As far as the mechanical part is involved, for both commercial and residential engineering, this works with anything which moves. In addition its involves the use of complex and uncomplicated machines and also other mechanical mechanisms to do certain tasks. Some ordinary mechanical engineering jobs which is often noticed everyday are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems which take care of increasing the energy productivity.

The electrical aspect of construction is focused on the components, functions, electrical safety, and above all, the wiring associated with a building. Engineers in this particular unit go to great lengths to ensure the schematics of the building are meant to bring adequate electricity to every individual component in a safe manner ensuring that every one of the electrical codes are followed. Some commonplace electrical engineering jobs can be obtained from the lighting design, modifying the voltage and distributing the electricity to every single component of structure that needs a supply.

As far as plumbing, there is certainly a variety of plumbing factors which constitute the final form of any building. Plumbing engineering goes deeper than only faucets, toilets, and sinks, and contains several behind the scene devices. These being the drainage line and sewage plus the buildings household water supply and exactly how it flows.

As we conclude this article we have just considered what is MEP Engineering. MEP Engineering is administered within the construction industry. And, helps with completing the simply overlooked technical facets of any building.

Hiring an MEP Engineering Firm in Kennedy Park Chicago is Important for Huge Construction Projects

Employing an MEP engineering firm in Rosemoor Chicago, ILO, might have everything to do with the safety of your construction project. These specialists might help offset the expense of making this kind of hiring decision when it comes to energy saving alone. When you are talking about big commercial buildings, energy saving is a crucial topic of discussion. It’s time to learn various other great reasons for employing MEP engineers in Rosehill Chicago, Illinois.

Engineers have everything to do with the structural integrity of a building. If you may well envision, this means the unseen is extreamly essential. Design not only deals in looks but the foundation of a building also its workings. Which is merely another solid reason why employing an MEP engineering firm will probably be helpful to any project.

Consider each of the pipes and plumbing. Consider the air conditioning systems and how important it is to get all of its components in the right places. Energy conservation was mentioned, but energy competence is an additional vital term to note. Energy competence is about your HVAC system, plus it plays an important part in energy conservation as a whole.

Take into consideration your building’s base. Consider setting up security systems and the safety and security measures put in place along the entire structure. With everything talked about thus far, it’s reliable advice that numerous elements of building construction may be either overlooked or underestimated without MEP engineers at work.

Now with all you know you are going to be looking for the best MEP engineering firm in the market, right? It is very obvious how the best engineers really need to be active in the large scale building of commercial buildings. Personalized will be the right term to make use of to explain just how these experts will adapt a construction project to meet the requirements of the operations. Even with all of this information you would like more info on the MEP Engineering services in Kennedy Park Chicago, IL by NY-Engineers.Com we invite you to take a look at our Kennedy Park Chicago CAD to Revit Modeling blog.

New Engineering Reports Related Post

How Construction Engineers are Improving HVAC Efficiency in Commercial Buildings with Variable Frequency Drives

Electrical Engineering Subjects

HVAC systems come in various configurations that differ significantly from each other. For example, an air conditioning system based on packaged rooftop units is drastically different from a chiller plant. However, HVAC installations have a common denominator: they use electric motors that are subject to variable loads. Regardless of whether these motors are used to drive compressors, water pumps or fans, construction engineers understand that there is a great opportunity to save energy by optimizing part-load operation.

In general, running a motor at partial speed is more energy-efficient than running it intermittently at full speed.

  • Intermittent operation only provides linear savings. For example, a cooling tower fan with a duty cycle of 80% consumes 20% less energy than an identical fan operating full-time.
  • Reducing motor speed provides cubic savings.. On the other hand, slowing down a fan to 80% speed reduces energy consumption by nearly 50%. The average airflow is the same as that of a fan running at full power 80% of the time, but savings are boosted significantly thanks to speed control.

Speed control can be accomplished with variable-frequency drives (VFD), and they have a broad range of applications in HVAC systems due to the cyclic nature of loads. It is important to note that VFDs are also known as variable-speed drives (VSD), adjustable-frequency drives (AFD) or adjustable-speed drives (ASD).

Fractional horsepower motors in small-scale HVAC systems can also achieve significant savings with speed control. The main difference here is that electronically commutated motors (ECMs) are more cost-effective than VFDs in these applications.

Ask a Construction Engineering Expert: How Does Variable Frequency Drive Work?

As explained by electrical engineering textbooks, the speed of an electric motor is defined by the power supply frequency and its internal construction. For example, a motor running at 1800 RPM with the 60 Hz USA power supply would run at 1500 RPM in the UK, where the frequency is 50 Hz. Thus, if a motor is suitable for operation at reduced frequency, its speed can be ramped down during part load conditions to achieve energy savings. VFDs are connected between the power supply and the motor, adjusting voltage and frequency as a means of speed control.

In applications where only single-phase power is available, VFDs can be used to integrate three-phase motors while achieving the energy efficiency benefits: there are models capable of producing a three-phase voltage from a single-phase input, while adjusting magnitude and frequency to control motor speed.

In addition to improving energy efficiency, VFDs allow motors to be soft-started by gradually ramping up the voltage and frequency, as opposed to directly applying full voltage at 60 Hz. Electric motors draw from five to eight times their rated current when started directly, and the voltage drop that results from the inrush current may damage sensitive equipment.

The main limitation of VFDs is that they produce a phenomenon called harmonic distortion, where high-frequency currents are induced in branch circuits. However, this can be controlled with a properly-specified harmonic filter; this device absorbs current distortions at the point of consumption, preventing their propagation throughout the installation.

VFD Applications in HVAC Systems

In most cases, VFDs are deployed by construction engineers in HVAC systems to control the speed of blower fans, pumps or compressors.

Cooling Tower Fans

The main purpose of a cooling tower is removing the heat from a water circuit, which may be used in turn for process cooling or for a chiller plant. Cooling towers use fans to establish an airflow, improving heat removal through convection. These are open discharge fans, where there is no ductwork creating resistance to airflow; hence, the savings opportunity through speed control is significant.

When a VFD is deployed for a cooling tower fan, speed is normally controlled based on water temperature. Rather than cycling the fan on and off, it can be driven at reduced speed so that the water returning to the chiller or process is kept at a constant temperature – as previously explained, reduced-speed operation is far more efficient than intermittent operation at full speed.

Air-Handling Units and Packaged Rooftop Units

Unlike the fans in cooling towers, those used in AHUs and packaged RTUs blow air into a duct system, which offers higher resistance and requires a specific static pressure and airflow to be established. These ducts may have several outlets with variable-air-volume (VAV) boxes, where airflow is controlled individually for each zone with a damper.

Without a VFD, the blower fan in the AHU or RTU operates at full speed, and each VAV box is adjusted individually. This is an inefficient approach, however – if neither of the VAV boxes is fully open, energy is being wasted in the form of extra pressure. On the other hand, if the blower is equipped with a VFD, an interesting energy-saving strategy becomes possible:

  • Blower speed can be gradually reduced while VAV boxes are opened incrementally, to keep the airflow and temperature constant.
  • The temperature of different zones is unaffected but pressure is reduced, saving energy.
  • Speed reduction continues until one of the VAV boxes reaches the fully open position. At this point it is not possible to reduce speed further without affecting indoor temperatures.

There is also a comfort benefit with this control strategy: the reduced pressure drop translates into less noise, making indoor environments more comfortable.

Speed Control for Water Pumps

Water circuits are a key element of many HVAC installations, including those that use chillers, boilers and water-source heat pumps. Since HVAC loads are variable, it is often necessary to adjust the water flow depending on total system load. There are three main ways to achieve this:

  • Choke Valve-A choke valve is installed in line with the flow, and as implied by its name it regulates flow by closing partially. This control method is simple, but the resulting pressure loss represents a considerable waste of energy.
  • Recirculation Valve-With this approach a valve is installed on a parallel recirculation circuit, and it is opened gradually to divert a part of the water flow, reducing the flow in the main circuit. In this case, however, there is also a significant energy loss because the recirculated water represents pumping power.
  • Pump Speed Control– The most energy efficient approach is to install a VFD on the pump motor. If a reduced water flow is required, it is just a matter of reducing the pump speed accordingly. With no pressure or recirculation losses, the savings achieved are significant. This setup also uses a choke valve for convenience, but it is normally kept in the fully open position, since the VFD regulates flow.

Chillers with Variable-Speed Compressors

In chilled water air conditioning systems, the chiller is by far the piece of equipment with the highest energy consumption. Therefore, installing the most efficient chiller model that can be afforded is highly recommended.

Energy efficient chillers have helical rotary compressors, capable of adjusting their speed with a VFD, depending on cooling needs. Some models may feature multiple individual compressors to achieve enhanced flexibility and increased part-load efficiency.

When a chiller is highly efficient, the control strategy is normally based on maximizing its capacity rather than running it at the lowest possible set point. The savings achieved by reducing the load on complementary systems tend to be far greater than the extra consumption at the chiller. There are exceptions, of course, and only monitoring and control can offer the correct answer 100% of the time.

Integrating the Entire HVAC System

Equipping all motors in an HVAC system with VFDs is a first step towards energy efficiency, but the best results can only be achieved with central control system, capable of assessing building conditions and adjusting HVAC set points in real time.

The interaction between a chiller and a cooling tower is a great example of how control engineering and VFDs can be applied to HVAC installations:

  • Reducing the cooling tower fan speed increases the cooling load on the chiller.
  • The reverse also applies: reducing refrigeration power at the chiller may require more heat to be rejected by the cooling tower.

If the chiller has a high efficiency, the best option in most scenarios is reducing the cooling tower load. However, only a control system can balance the operation of both components in real time. Ideally, the control system should be able to determine the set point for each individual VFD so that power consumption is minimized at the total system level.

Of course, the performance of an HVAC system starts from the design phase. For optimal results, make sure you work with licensed and qualified construction engineers and other HVAC professionals. Installing an efficient and automated HVAC system from the start is much less expensive than upgrading an existing installation.

searches related to Plumbing Engineering in Kennedy Park Chicago, Illinois.

Architectural Engineering Degree

(MEP) Engineering Service in Kennedy Park Chicago

How Can Our Kennedy Park Chicago MEP Engineers Help You! A large group of general contractors throughout Huntington Station, NY have come to depend on New York Engineers for a wide range of engineering services ranging from Electrical Engineering to Engineering Reports. For this reason developers in Kennedy Park Chicago will tell you that if you are seeking a top-rated MEP Engineering firm in Kennedy Park Chicago, IL you should consider NY-Engineers.Com. [...]