MEP Service in Machesney Park, Illinois.

Contact Us

Searching for a top MEP Firms in Chicago? The one to go to is NY-Engineers.Com. Not only for MEP Chicago but also Architectural Engineering and Sprinkler Engineering throughout Machesney Park. Call us at (+1) 312 767.6877

Contact Us
Local MEP Engineering

Developers throughout Harrison, New York have come to rely on NY Engineers for a wide range of engineering services ranging from Electrical Engineering to Engineering Reports. For this reason property owners in Machesney Park will tell you that if you are looking for a top-rated MEP Engineering firm in Machesney Park, Illinois you need to consider NY-Engineers.Com.

Odds are, you might have walked through any specific sort of building and seen the final results of MEP Engineering. To put it simply, MEP centers in the mechanical, electrical and plumbing facets of engineering. Basically, the name already gives rise to the most prevalent and precise theory of what is MEP. This article will go into some specifics of what is MEP Engineering.

So far as the mechanical side is concerned, for both commercial and residential engineering, this works with anything that moves. Additionally its involves the use of complex and simple machines together with other mechanical mechanisms to execute certain tasks. Some normal mechanical engineering tasks that may be noticed everyday are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems that cope with increasing the energy efficiency.

The electrical facet of construction is centered on the functions, components, electrical safety, and most importantly, the wiring of any building. Engineers in this particular branch go to great lengths to make sure that the layout of a building are made to supply enough power to every component in a safe manner ensuring that all the electrical codes are met. Some familiar electrical engineering tasks can be found in the lighting design, modifying the voltage and allocating the power to each component of building which needs a supply.

As far as plumbing, there is certainly a variety of plumbing factors that constitute the final style of any structure. Plumbing engineering goes deeper than simply toilets, faucets, and sinks, and holds several behind the scene appliances. These being the drainage line and sewage and also the buildings local water supply and the way it flows.

As we wrap up our article we have now just checked out what is MEP Engineering. MEP Engineering is administered in the construction industry. And, supports completing the simply overlooked technical elements of any building.

Hiring an MEP Engineering Firm in Machesney Park is Essential for Huge Construction Projects

Employing an MEP engineering company in Bucktown Chicago, ILO, might have a whole lot to do with the prosperity of your construction project. These engineers will help offset the fee for making this kind of hiring decision in terms of energy conservation alone. If you are referring to huge commercial structures, energy management is a crucial topic of discussion. It’s time to determine various other great factors behind using MEP company in Grand Boulevard Chicago, Illinois.

Engineers play an important role in the physical integrity of your building. If you may well envision, it means the hidden is very essential. Design not just deals in aesthetics but the underpinning of a building also its components. Which is merely another solid reason why using an MEP engineering company will probably be helpful to any project.

Think about all the pipes and plumbing. Think about the air conditioning systems and how important it is to get each one of its components inside the correct places. Energy saving was discussed, but energy efficiency is yet another vital term to bring up. Energy competence is about your HVAC system, and it plays a vital part in energy saving in general.

Consider your building’s footing. Consider the installation of security alarms and also the safety and security measures put in place through the structure. With everything else described so far, it’s safe to say that lots of aspects of building construction may be either disregarded or underestimated without MEP engineers on-the-job.

Now with all you have read you are going to be looking for the very best MEP engineering company in the industry, right? It is pretty clear the best engineers must be in the large scale construction of commercial structures. Customized will be the right term to utilize to explain just how these engineers will adapt a construction project to meet the requirements of your respective operations. There is a great possibility you would like more information about the MEP Engineering services in Machesney Park, Illinois by New York Engineers we invite you to check out at our blog.

Latest Value Engineering Related Article

Architectural Engineers Detail Ventilation System Configurations

Value Engineers Near Me

Human activity generates a broad range of compounds that become dangerous in high-enough concentrations, and pollutants from outdoor sources can also degrade indoor air quality. Architectural engineers are often charged with the job of preventing this from occurring as much as possible.

Ventilation systems keep these substances at low levels by constantly renewing indoor air, and they also contribute to keeping moisture within the range of 30 to 60 percent as recommended by ASHRAE. Without ventilation, it would not be possible to keep indoor environments comfortable and healthy.

Natural ventilation relies on wind currents, outdoor temperature and other weather conditions to supply fresh air. The advantage of natural ventilation is that it comes for free, and in new buildings it is possible to optimize architectural design to maximize its effects. However, natural ventilation is uncontrollable, and generally insufficient to fully meet the requirements of modern buildings.

Normally, to meet ASHRAE standards and local building codes, mechanical ventilation must be deployed. Depending on their configuration, whole-house ventilation systems can be classified into three main types:

  • Exhaust ventilation systems, which only use extractor fans.
  • Supply ventilation systems, which only use injector fans.
  • Balanced ventilation systems, which use both injector and extractor fans.

Balanced systems can be enhanced with energy-recovery ventilation, a technology that exchanges energy between the supply and exhaust airflows to maximize performance and minimize the overall running cost of the system.

Exhaust Ventilation Systems

As implied by their name, exhaust ventilation systems only deploy extractor fans. When the system starts to run, it creates a negative pressurization effect in occupied spaces, drawing in fresh outdoor air to renew that which is exhausted. It is important to note, however, that exhaust ventilation is not possible in air-tight buildings, since outdoor air must be allowed to leak in. If the building envelope has been tightened with caulking and weather stripping, exhaust ventilation must be complemented with intake vents.

Exhaust ventilation systems have a single set of fans and ducts, which makes them affordable while reducing their installation time and cost. Energy expenses are relatively low because there is only one set of fans in operation, and maintenance is simplified as well. The system layout can be designed to target specific areas where pollutants are generated, ensuring they are removed before they spread indoors.

Exhaust ventilation generally achieves the best results in cold and dry climates, where outdoor air does not require dehumidification. It is not recommended for tropical and mixed climates, because warm and humid outdoor air is drawn in without control, driving up cooling and dehumidification expenses. Also, keep in mind that depressurization draws air from all surrounding spaces, with little control over pollutant content. In general, architectural engineers recommend exhaust ventilation for cold weather, and when outdoor air pollution is low.

Another risk of exhaust ventilation is backdraft, which occurs when a combustion-based appliance suddenly draws in a lot of air, potentially causing a flashover. Since exhaust ventilation causes negative pressurization and does not control air supply, there is an increased chance of backdraft.

Supply Ventilation Systems

Supply ventilation only uses injector fans, pressurizing rooms and causing indoor air to leak out constantly. The main advantage of supply ventilation is control, since outdoor air can be filtered, humidified or dried as needed. In addition, the pressurization effect prevents the inflow of pollutants from surrounding spaces or from outdoors.

Another benefit of supply ventilation is that it eliminates the risk of backdraft from combustion appliances due to positive pressurization. Installation, operation and maintenance expenses are also reduced thanks to the simple system configuration.

Supply ventilation is better suited for tropical or mixed climate conditions, where dehumidification and filtering are often required. This configuration tends to cause trouble in cold weather, since the pressurization effect can cause condensation of indoor air humidity, leading to moisture accumulation and its common side-effects: furniture damage and the proliferation of mold, bacteria and dust mites.

Balanced Ventilation Systems

A balanced ventilation system is the result of combining exhaust and supply ventilation: both airflows can be controlled, providing the benefits of both system configurations. Of course, this comes at a higher installation and operation cost, since there are now two sets of fans and ducts.

Balanced ventilation is suitable for all weather conditions, and airflows can be adjusted to provide any pressurization effect as required – positive, negative or neutral. The recommended locations for each set of ducts are the following:

  • Supply ducts should focus on areas where occupants spend most of their time, including living rooms and bedrooms. This ensures that these areas always have a supply of fresh and clean air.
  • Exhaust ducts should focus on areas where moisture and humidity are released frequently, such as kitchens, bathrooms, laundries and boiler rooms.

Of course, it is possible to install supply and exhaust rooms for every room, but system costs are increased significantly. With the approach presented above, system costs are optimized without compromising performance.

Energy-Recovery Ventilation: Architectural Engineers Improve the
Efficiency of Balanced Ventilation

Energy-recovery ventilation consists on exchanging energy between the supply and exhaust air, so that overall HVAC costs are minimized. These systems can be classified into two main types:

  • Heat-Recovery Ventilation (HRV)systems only exchange heat between the supply and exhaust airflows.
  • Enthalpy-Recovery Ventilation (ERV)systems exchange both heat and moisture.

Summer Operation

In the summer, outdoor air typically requires cooling and dehumidification. However, when air is exhausted, it is still cooler and drier than the supply air; therefore, a part of the energy used for cooling and dehumidification is lost.

  • The use of a heat exchanger (HRV) can improve energy efficiency: the exhaust air is used to precool the supply air without mixing both airstreams.
  • If an ERV system is used, moisture is also transferred from the supply air to the exhaust air, further improving air-conditioning efficiency because there is less moisture to remove.

Winter Operation

During the winter, HVAC needs are reversed because outdoor air typically requires heating and humidification. The operating principle of HRV and ERV is the same, but the direction in which heat and humidity are transferred is inverted.

  • The exhaust air is warmer, and the heat exchanger captures a part of that thermal energy to preheat the supply air.
  • If ERV is used, moisture is also retrieved from the exhaust air and provided to the supply air.

General Recommendations for HRV and ERV

It is important to note that HRV and ERV systems are significantly more complex than the ventilation systems presented before. They can only be installed and serviced by qualified personnel, which increases their cost of ownership. Compared with a basic balanced ventilation system, HRV and ERV systems have a higher running cost, but overall HVAC expenses are reduced.

HRV and ERV systems increase in effectiveness where temperature  and moisture extremes are reached during the summer or winter, or when heating fuel costs are high. Their benefits are diminished under moderate weather conditions, where the added running cost may be higher than the savings achieved – balanced ventilation is a better alternative in these cases.

Spot Ventilation: A Complement for Whole-House Ventilation

Spot ventilation consists on using exhaust fans to extract pollutants and humidity at the room where they are released, preventing them from being spread throughout other indoor spaces. In residential settings, spot ventilation is most commonly used in bathrooms and kitchens to meet the minimum exhaust air levels established in both the area mechanical codes and ASHRAE standards:

  • Bathrooms require 50 cfm of intermittent ventilation or 20 cfm of continuous ventilation.
  • Kitchens require 100 cfm or intermittent ventilation or 25 cfm of continuous ventilation.

Spot ventilation can be a great complement for supply ventilation systems, removing pollutants from key areas. This combination provides many of the benefits of a balanced ventilation system without having to install a full set of exhaust fans and ducts. According to experienced architectural engineers, the only disadvantage of this combination is that HRV and ERV systems are unfeasible, since there is no point where heat or moisture can be exchanged between airflows.

Popular searches related to Construction Administration Machesney Park, Illinois.

Construction Engineers Near Me

(MEP) Engineering Service in Machesney Park

MEP Firm Machesney Park! When you're looking for a reliable MEP Chicago in Firm? Your best bet is to reach out to is New York Engineers. Not only for MEP Firms in Chicago but also Construction Engineering and Sprinkler Engineering in or near Machesney Park. Contact us at 312 767.6877 Quite a few construction companies throughout Merrick, NY have come to depend on NY-Engineers.Com for a wide range of engineering services [...]

2018-09-03T23:58:02+00:00