MEP Service in North Chicago, IL.

Contact Us

Looking for the best MEP Chicago? Your best bet is to contact is NY-Engineers.Com. Not only for MEP Engineering in Chicago but also Value Engineering and Sprinkler System Engineering near North Chicago. Contact us at 312 767.6877

Contact Us
Electrical Engineering Careers

Developers throughout Cortland, New York have come to depend on NY Engineers for a wide range of engineering services ranging from Mechanical Engineering to Engineering Reports. That is why property owners in North Chicago will tell you that if you are searching for a excellent MEP Engineering firm in North Chicago, Illinois you need to consider New York Engineers.

No doubt, you may have walked into any specific sort of building and seen the final results of MEP Engineering. Basically, MEP concentrates on the mechanical, electrical and plumbing facets of engineering. Basically, the name already gives rise to the most typical and correct assumption of what exactly is MEP. This article should go into some specifics of what is MEP Engineering.

As far as the mechanical side is involved, both for residential and commercial engineering, this relates to anything that moves. Additionally its entails the usage of complex and simple machines and also other mechanical mechanisms to do certain tasks. Some normal mechanical engineering jobs that may be noticed regularly are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems which handle improving the energy productivity.

The electrical element of construction is centered on the functions, components, electrical safety, and above all, the wiring of the building. Engineers in this section go to great lengths to ensure the schematics of any building are made to provide ample power to every individual component in a safe manner where every one of the electrical codes are followed. Some familiar electrical engineering jobs can be found in the lighting design, regulating the voltage and allocating the energy to each and every component within the structure which takes a supply.

With regards to plumbing, there exists a wide array of plumbing components that make up the final style of any building. Plumbing engineering goes deeper than merely sinks, faucets, and toilets, and contains several behind the scene appliances. These being the sewage and drainage lines and also the buildings domestic water supply and the way it flows.

As we wrap up our article we have now just considered what is MEP Engineering. MEP Engineering is administered within the construction industry. And, assists in completing the simply overlooked technical areas of any building.

Hiring an MEP Engineering Firm in North Chicago is Important for Major Construction Projects

Hiring an MEP company in Garfield Ridge Chicago, Illinois, might have a whole lot to do with the achievements of your construction project. These specialists can help offset the fee for making such a hiring decision when it comes to energy conservation alone. If you are speaking about large commercial structures, energy upkeep is an important topic of discussion. It’s time to find out a few other great reasons behind employing MEP company in Norwood Park West Chicago, IL.

Engineers have everything to do with the structural reliability of any building. As you may well imagine, this means the hidden is very vital. Design not only deals in looks but the groundwork of a building and its components. That may be yet another solid good reason that employing an MEP engineering firm is going to be beneficial to any project.

Think about each of the pipes and plumbing. Look at the heating and cooling systems and the importance of getting all its mechanics inside the precise places. Energy conservation was mentioned, but energy efficiency can be another vital term to discuss. Energy competence has everything to do with your HVAC system, and it plays an important part in energy conservation in general.

Think of your building’s base. Consider the installation of home security systems and also the safety and security measures put in place throughout the structure. With everything discussed to date, it’s safe to say that lots of aspects of building construction might be either disregarded or minimized short of MEP professionals at work.

Now with all you know you are going to be looking to get the best MEP engineering firm in the industry, right? It is very clear that this best engineers have to be active in the massive construction of commercial structures. Personalized will be the best term to make use of to describe just how these specilists will modify a construction job to meet the requirements of your respective operations. There is a great possibility you would like additional details about the MEP Engineering services in North Chicago, Illinois by NY Engineers you should visit at our North Chicago CAD to Revit Modeling blog.

Construction Administration Related Blog Article

Construction Engineers Explain How HVAC Systems Move Heat

Fire Protection Engineering Jobs

Heat movement is required for both space heating and air conditioning. Space heating systems deliver heat and air conditioning systems remove it, but the goal in both cases is reaching a suitable indoor temperature. Construction engineers can explain how, though heat can be transmitted across empty space by radiation, using convection and the bulk movement of a fluid is much more effective. In HVAC applications, the most common fluids used to carry heat are air, water, refrigerants, and steam.

Since each substance has different properties, the heat distribution fluid used by an HVAC system determines many performance features. Also consider that different fluid may be used in the same system, with intermediate heat exchange steps.

Heat Distribution with Air

The main advantage of using air to carry heat is simplicity: air is already present in the atmosphere and indoor spaces, so there is no need to use additional fluids in the HVAC system.  Air can interact directly with AC compressors, furnaces or heat pumps to adjust its temperature, and it can then be distributed using fans and ductwork.

However, air ducts require more space than the piping used by other heat-carrying fluids, and they are impractical when air must travel long vertical distances. Consider that warm air rises while cool air tends to fall below, and fan power increases dramatically if you need to move air against its natural behavior. This is neither practical nor energy efficient!

When air ducts must serve separate zones, its distribution is typically controlled with air dampers. These can adjust their position between fully open and fully closed as needed to regulate airflow, and they are controlled automatically by the thermostats in each zone.

One of the most promising system upgrades for air distribution systems promoted by construction engineers is adding variable frequency drives (VFD) to the fans. Reducing fan speed is much more efficient than intermittent operation when you don’t need the full rated airflow. In the case of fractional horsepower fans, a brushless DC motor is recommended instead of a VFD, since they come with built-in speed control.

Packaged rooftop units are an example of an HVAC system that uses air as the main heat distribution and heat removal medium.

Heat Distribution with Water

Some HVAC systems heat or cool water instead of air, and water then interacts with indoor air through fan coils. When this configuration is used, the installation is referred to as a hydronic system. Compared with air, water can hold much more heat per unit of volume, thanks to its higher specific heat and density. As a result, it is the preferred heat-carrying medium in large commercial and industrial installations: hydronic piping uses much less space than air ducts for a given heating or cooling load.

Just like airflow can be controlled with dampers and VFD-equipped fans, the flow of water in a hydronic system can be controlled with valves and VFD-equipped pumps. The basic principle is the same: finding an operating point where each zone is kept at the required temperature and humidity, at the lowest energy cost possible.

Chillers and boilers are two examples of HVAC systems that rely on water to carry heat. Indoor air can then be heated or cooled using fan-coils. Another possible configuration is using larger air-handling units (AHU) connected to an air duct system, where heat exchange occurs between the hydronic piping and the air being circulated by the AHU.

Refrigerant

All air conditioning compressors and heat pumps use refrigerant internally, but there also HVAC systems with longer refrigerant lines connecting different pieces of equipment. Refrigerant lines are even more compact than hydronic piping, not to mention air ducts. Just like when water is used to carry heat, refrigerant flow can be controlled with the combination of valves and variable speed control for the compressor.

Ductless air conditioners and heat pumps use refrigerant lines between the condenser and evaporator units, and typically offer a very high efficiency. The concept can also be applied for multiple zones served by a single outdoor unit, using a variable refrigerant flow system (VRF). VRF systems are very efficient as well, while consolidating heating and cooling systems into a single installation.

Steam

Many buildings in New York City use steam as a heat-carrying fluid, since a significant portion of the city gets steam as a utility service from Con Edison. However, if you plan to install your own boiler, a hot water system is preferred over a steam system.

The main drawback of steam is that you can use it only for heating in most cases. The only way to achieve cooling with steam through an absorption chiller, but a conventional electric chiller is much more economic in multifamily and commercial settings. Absorption chillers are better suited for applications where heat is available at a very low cost or as a waste product of industrial activity – not when you are paying for steam as utility service.

Since steam cannot be used directly for cooling, buildings with steam radiators often have window-type or through-the-wall air conditioning units. These normally suffer from poor efficiency, so you can consider upgrading to ductless units while the heating system is retrofitted to use hot water.

Our Construction Engineers’ Conclusion

HVAC systems are characterized by their variety, and each configuration brings a different set of performance features. Working with qualified HVAC consultants and construction engineers is recommended to identify the system configuration that works best, according to the specific needs of your building. Also keep in mind that only a registered design professional can submit HVAC designs for approval by the NYC Department of Buildings.

searches related to Value Engineering North Chicago, IL.

Electrical Engineering Information

(MEP) Engineering Service in North Chicago

MEP Firm North Chicago! If you re looking for a fast responding MEP Chicago in Firm? The top choice is is NY-Engineers.Com. Not only for MEP Chicago but also Electrical Engineering and Protection Engineering in or near North Chicago. Call us at (312) 767.6877 Many general contractors throughout Franklin Square, New York have come to depend on NY-Engineers.Com for a wide range of engineering services ranging from Sprinkler Engineering to Value [...]

2018-09-18T22:37:50+00:00