MEP Service in Rock Island, Illinois.

Contact Us

Looking for MEP Firms in Chicago? Your best bet is to reach out to is New York Engineers. Not only for MEP Firms in Chicago but also Architectural Engineering and Sprinkler Design Engineering in Rock Island. Call us at 312 767-6877

Contact Us
Fire Protection Engineering Jobs

Property owners throughout Auburn, New York have come to rely on NY Engineers for a wide range of engineering services ranging from Sprinkler Engineering to Value Engineering. This is why real estate investors in Rock Island will tell you that if you’re looking for a dependable MEP Engineering firm in Rock Island, IL you need to consider NY-Engineers.Com.

Chances are, you may have walked into any specific type of building and saw the outcomes of MEP Engineering. Basically, MEP concentrates around the mechanical, electrical and plumbing aspects of engineering. In essence, the name already gives a clue to the most common and spot-on guess of what exactly is MEP. Our article will go into some information on what is MEP Engineering.

As far as the mechanical aspect is concerned, both for commercial and residential engineering, this deals with anything that moves. Moreover its involves the usage of complex and uncomplicated machines and also other mechanical mechanisms to perform certain tasks. Some normal mechanical engineering tasks that may be noticed on a day to day bacis are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems that handle increasing the energy productivity.

The electrical element of construction is focused on the electrical safety, functions, components, and most importantly, the wiring of the building. Engineers within this branch go to great lengths to ensure the schematics of any building are meant to bring ample power to every component in a safe manner where all the electrical codes are met. Some common electrical engineering jobs can be found in the lighting design, regulating the voltage and distributing the power to each component of structure which needs a supply.

With regards to plumbing, there is certainly a variety of plumbing components which make up the final style of any building. Plumbing engineering goes deeper than simply faucets, toilets, and sinks, and houses several behind the scene devices. These being the sewage and drainage lines as well as the buildings household water supply and just how it flows.

As we conclude this article we certainly have just looked at what is MEP Engineering. MEP Engineering is managed within the construction industry. And, assists in completing the often unnoticed technical aspects of any building.

Hiring an MEP Engineering Firm in Rock Island is Important for Huge Construction Projects

Employing an MEP engineering firm in Beverly View Chicago, Illinois, could have everything to do with the safety of your construction project. These professionals may help offset the fee for making this kind of hiring decision with regards to energy management alone. When you find yourself discussing huge commercial buildings, energy management is an important topic of discussion. It’s time to determine another great causes of employing MEP engineering company in North Center Chicago, Illinois.

Engineers have a great deal to do with the structural integrity of your building. If you can well envision, it means the hidden is very important. Design not simply deals in aesthetics but the base of a building also its mechanism. That is certainly merely another solid reason why employing an MEP engineering firm is going to be useful to any project.

Think of each of the pipes and plumbing. Consider the cooling and heating systems and the importance of getting each one of its components in the exact places. Energy maintenance was discussed, however energy efficiency is yet another vital term to mention. Energy efficiency is related to your HVAC system, and it plays a huge role in energy conservation overall.

Think of your building’s shell. Consider installing fire alarm systems and the security and safety measures set up through the entire structure. With everything else described up to now, it’s reliable advice that lots of aspects of building construction might be either ignored or minimized short of MEP engineers at the job.

Now with all you know you are going to be looking for the best MEP engineering company in the industry, right? It’s pretty obvious the best engineers must be working in the large construction of commercial buildings. Tailor made is definitely the right term to use to clarify how these pros will customize a construction project to meet the needs of your operations. There is a great possibility you would like additional info on the MEP Engineering services in Rock Island, IL by NY Engineers we invite you to check out at our blog.

Latest CAD to Revit Modeling Related Article

Mechanical Engineers Design HVAC Systems for Sensitive Environments

MEP Engineering Pdf

A well-designed HVAC system keeps temperature and moisture within a range that is considered comfortable for humans, while constantly renewing the air in a building and filtering out pollutants. Mechanical engineers are, in large part, responsible for ensuring that an HVAC system is operating as it should. The system must also provide an adequate airflow, since stagnant air and draftiness are both detrimental for performance.

In most residential and commercial settings, deviations from the ideal operating conditions are allowable if they are transitory, and there is generally a broad range of acceptable temperature and humidity values. However, there are sensitive environments such as healthcare facilities, where optimal conditions must be kept at all times. Many HVAC systems in less demanding environments are controlled based on temperature only, and humidity is controlled indirectly. However, sensitive environments require that each variable be monitored and controlled independently, and specialized high-performance filters may be required by codes.

Humidity Control in Sensitive Environments

Precise humidity control is typically required for environments with sensitive electronic equipment, healthcare facilities and other similar locations were human life or important systems are at stake. For example, the relative humidity levels for healthcare typically range from 40 to 60 percent:

  • Bacteria and viruses thrive with both low and high humidity levels.
  • Patients who suffer from asthma or allergic rhinitis also experience symptoms in response to humidity extremes.
  • Dry air absorbs moisture from mucous membranes, reducing the body’s ability to fight off infections.
  • Low humidity also increases static electricity accumulation, and discharges can damage modern medical equipment, which is important for medical procedures and generally expensive
  • Dust has a higher tendency to become airborne at low humidity levels, further increasing the chance of triggering allergic reactions.
  • High humidity creates the ideal conditions for mold and dust mites.

Depending on weather conditions, an HVAC system may be required to operate in humidification or drying mode at different times of the year. Some areas of a sensitive environment may have more stringent requirements than others; surgery rooms in hospitals are an example of this. It is the responsibility of qualified mechanical engineers to understand what is needed across various projects.

Air Dehumidification

There are two main approaches for controlling air humidity independently: the HVAC system can use cooling and heating coils in series, or a desiccant wheel can be deployed.

  • Cooling and heating coils: With this approach, air is cooled and dehumidified by the cooling coil until the desired relative humidity is reached. Since this normally results in overcooling, air then flows through a heating coil to raise its temperature back to an acceptable level. This way, both temperature and humidity requirements are met.
  • Desiccant wheel: This device captures air humidity downstream from the cooling coil, and releases it upstream for it to be condensed and gathered. At design conditions, this system does not require any heating input, although a preheating coil is added in case extra dehumidification is required.

Desiccant wheels typically save energy because they eliminate the need for overcooling and reheating. There may be exceptions, however, so it is important to assess each installation independently.

Air Humidification

Healthcare humidification systems are often based on steam, since heating water to high temperatures ensures the destruction of bacteria, especially Legionella. When steam is injected into an airstream, both humidification and heating are accomplished in the same step.

In the most sensitive environments, such as surgery rooms, steam-based humidification is normally required by law to ensure that the system is free from airborne bacteria. Adiabatic humidification is accepted in some sensitive applications, and it provides considerable savings compared with steam systems, although it is necessary to ensure it can be used legally.

Vapor Diffusion Retarders

Vapor diffusion retarders, also known as vapor barriers, complement air drying and humidification systems by providing a barrier against the diffusion of moisture through walls or other elements of the building envelope. Vapor diffusion retarders are classified into three main categories, depending on their rated permeance value:

  • Class I vapor barriers are rated for 0.1 perms or less. Some examples are glass, sheet metal and polyethylene.
  • Class II vapor barriers are rated for permeance values above 0.1 perms but less than or equal to 10 perms. Plywood and unfaced extruded polystyrene are two examples.
  • Class III vapor barriers have permeance values above 10 perms, and some examples are gypsum board, cellulose insulation, bricks and concrete blocks.

The specification of vapor barriers is strongly dependent on weather conditions, and can be especially challenging in northern states, due to how drastically temperature and relative humidity fluctuate throughout the year. Getting in touch with a qualified design firm is highly recommended.

Ventilation for Sensitive Environments: Air Changes per Hour and Filtering

Ventilation systems for sensitive environments must meet specific requirements in terms of air changes per hour (ACH). In surgery rooms, for example, the American Institute of Architects establishes 15 ACH, where 20% must be outdoor air.

  • In a surgery room with a floor area of 600 ft2 and a height of 10 ft, 15 ACH is equivalent to 90,000 ft3 per hour, or 1500 cfm. The outdoor air required would be 300 cfm to meet the 20% requirement.

Filters for sensitive applications must typically meet a minimum MERV rating, and in applications that are especially sensitive compliance with the HEPA standard may be required.

MERV Ratings

MERV stands for Minimum Efficiency Reporting Value, and it is a measurement scale for the effectiveness of filters, which was developed by ASHRAE in the 80s. The scale of MERV ratings ranges from 1 to 16, where larger numbers indicate that the filter is rated for smaller particles and has a higher average arrestance.

  • MERV 1-4: 60 to 80% arrestance, particles larger than 10.0 µm.
  • MERV 5-8: 80 to 95% arrestance, 3.0 to 10.0 µm.
  • MERV 9-12: 90 to 98% arrestance, 1.0 to 3.0 µm.
  • MERV 13-16: Over 95% arrestance, particles from 0.30 to 1.0 µm.

In healthcare applications, filters with MERV ratings of 7 or more are normally specified. In some applications, two filters in tandem are used, where the second has a higher MERV rating than the first.

HEPA Standard

HEPA stands for High-Efficiency Particulate Arrestance, and a filter must remove 99.97% of particles with a diameter of 0.3 µm to qualify as such. It is important to note that the term HEPA has been adopted to refer to any high-efficiency filter, but only those meeting the requirements set forth in the standard are real HEPA filters.

In healthcare applications, HEPA filters are widely used thanks to their ability to capture airborne bacteria and viruses. Once they have been trapped, high-power ultraviolet lights are used to kill them.

It is important to note that higher performance filters also involve an increased pressure drop, raising energy consumption. For this reason, it is important to select a filter with adequate performance for the application, but not over-specified.

General Recommendations from Mechanical Engineers for Sensitive Environment HVAC Design

The most important requirement for HVAC systems in sensitive environments is being able to control humidity and temperature simultaneously, while filtering out pollutants. Therefore, designs based on rules of thumb should be avoided:

  • Sizing air conditioning equipment in tons per square foot of floor area.
  • Sizing ventilation equipment in cfm per ton of HVAC capacity.

Instead, each system must be designed by mechanical engineers to meet a specific temperature and humidity range, as well as air changes per hour and percentage of outdoor air. Hiring the services of qualified engineering professionals is highly recommended to ensure that requirements are met.

searches related to Fire Protection Engineering Rock Island, Illinois.

Structural Engineering Near Me

(MEP) Engineering Service in Rock Island

MEP Company Rock Island! If you're searching for a reliable MEP Engineering in Chicago? The one to go to is is New York Engineers. Not only for MEP Firms in Chicago but also HVAC Engineering and Protection Engineering in Rock Island. Call (+1) 312 767.6877 A great number of construction companies throughout Ronkonkoma, New York have come to depend on NY Engineers for a wide range of engineering services ranging from [...]

2018-08-31T07:33:42+00:00