MEP Service in The Island Chicago, IL.

Contact Us

Searching for the best MEP Firms in Chicago? Your best bet is to call is NY Engineers. Not only for MEP Firms in Chicago but also Mechanical Engineering and Sprinkler Design Engineering in or near The Island Chicago. Call (312) 767-6877

Contact Us
Electrical Engineering Careers

Developers throughout Syracuse, New York have come to rely on New York Engineers for a wide range of engineering services ranging from Electrical Engineering to Energy Modeling. That is why construction companies in The Island Chicago will tell you that if you are searching for a top-rated MEP Engineering firm in The Island Chicago, Illinois you should consider New York Engineers.

Chances are, you may have walked into any specific form of building and saw the outcome of MEP Engineering. To put it simply, MEP centers around the mechanical, electrical and plumbing areas of engineering. In essence, MEP already gives a clue to the most common and accurate guess of precisely what is MEP. This article may go into some details of what is MEP Engineering.

As far as the mechanical aspect is involved, for both commercial and residential engineering, this deals with anything that moves. Moreover its involves the application of complex and easy machines together with other mechanical mechanisms to do certain tasks. Some normal mechanical engineering tasks that may be noticed everyday are HVAC units, kitchen or bath exhausts, cooling and heating air systems and equipment and systems which cope with improving the energy efficiency.

The electrical part of construction is focused on the functions, components, electrical safety, and more importantly, the wiring for any building. Engineers in this particular department try very hard to ensure that the schematics of your building are made to supply adequate electricity to every component in a safe manner ensuring that every one of the electrical codes are followed. Some commonplace electrical engineering tasks may be found in the lighting design, modifying the voltage and allocating the energy to each component inside the structure which requires a supply.

So far as plumbing, there is a variety of plumbing factors which make up the final form of any structure. Plumbing engineering goes deeper than merely toilets, faucets, and sinks, and holds several behind the scene devices. These being the sewage and drainage lines as well as the buildings domestic water supply and the way it flows.

As we conclude this article we certainly have just checked out what is MEP Engineering. MEP Engineering is managed inside the construction industry. And, aids in completing the often ignored technical aspects of any building.

Hiring an MEP Engineering Firm in The Island Chicago is Important for Large Construction Projects

Employing an MEP firm in Longwood Manor Chicago, ILO, can have a whole lot to do with the achievements of your construction project. These specialists can help offset the cost of making this type of hiring decision in terms of energy conservation alone. If you are referring to large commercial buildings, energy management is really a topic of discussion. It’s time to find out some other great factors behind employing MEP engineering firm in Jackson Park Highlands Chicago, IL.

Engineers play an important role in the structural reliability of the building. If you may well imagine, this means the unseen is extreamly essential. Design not only deals in aesthetics but the basis of a building including its mechanism. Which is yet another solid logic why using an MEP engineering company will be helpful to your project.

Take into consideration all the pipes and plumbing. Think about the heating and cooling systems and how important it is to get all of its mechanics in the precise places. Energy saving was discussed, but energy efficiency can be another important term to note. Energy competence is related to your HVAC system, plus it plays a huge part in energy maintenance in general.

Think of your building’s foundation. Consider the installation of security alarms and the safety and security measures set up throughout the structure. With everything mentioned up to now, it’s safe to say that a great many areas of building construction might be either ignored or minimized without MEP experts at work.

Now with all you have read you are going to be looking to get the best MEP engineering firm in the business, right? It is very obvious that the best engineers need to be involved in the large scale construction of commercial buildings. Customised will be the best term to make use of to illustrate how these specilists will customize a construction project to meet the needs of your operations. There is only so much you can save this page if you would like more information on the MEP Engineering services in The Island Chicago, IL by New York Engineers we invite you to stop by at our The Island Chicago MEP Engineering blog.

Sprinkler Engineering Related Blog Post

An Electrical Engineer’s Guide to Circuit Breakers: Overview and Applications

MEP Engineering Firms

Circuit breakers are fundamental elements for a safe and code-compliant electrical installation. Conductors and electrical equipment are exposed to damage and malfunction, and there is always a risk that someone may connect a device incorrectly or use it for the wrong application. Electrical engineers see these issues frequently in their line of work. These conditions can cause a device to draw current above its rated value, and the corresponding circuit breaker trips to disconnect the fault.

Before providing an overview of circuit breakers, it is important to understand the difference between the two main current conditions that cause a circuit breaker to trip.

  • An overload current occurs when a device draws current above its rated value, but not by a drastic margin. For example, a motor that is rated at 60 Amperes but drawing 75 Amperes is likely suffering an overload condition.
  • A fault current is orders of magnitude higher than the rated current of a circuit, and it occurs when a live conductor touches another at a different voltage (short circuit), or a conductive surface (ground fault). There is a high-magnitude current in both cases, since low-resistance contact is established across a voltage difference. For example, a residential circuit normally carrying 20 Amperes may experience a few thousand Amperes during a fault.

A circuit breaker must trip under both conditions, but the ideal trip response is different for each case:

  • The response to an overload current should have a time delay. Some types of equipment draw current above their rated value for short periods of time as part of their normal operation. For example, electric motors draw an inrush current up to 8 times their rated current when they start.
  • The response to a fault current should be instantaneous. These currents are not normal under any operating conditions, and they must be cleared immediately when detected.

Given this combination of performance requirements, most circuit breakers actually have two protection mechanisms in a single device. There is a thermal protection mechanism that responds to overload current, and a magnetic protection mechanism that responds to fault currents.

Thermal and Magnetic Protection

The thermal protection mechanism in a circuit breaker is based on an expanding contact: the circuit is interrupted once the contact expands beyond a certain point. The circuit breaker is calibrated so that the contact will not open below rated current, but any current conditions exceeding it will eventually cause a trip. Since current is the heat source that expands the contact, more severe overload conditions cause a faster expansion and a shorter trip time.

The magnetic protection mechanism is based on induction. Current passes through a coil inside the circuit breaker, creating a magnetic field that opens the connection. The field is too weak to trip the breaker under normal operating conditions, but high-magnitude currents cause a strong magnetic field that forces the breaker open.

Main Types of Circuit Breakers, as Explained by Electrical Engineers

Most circuit breakers found in residential and commercial buildings are either miniature circuit breakers (MCB) or molded-case circuit breakers (MCCB). MCBs are more compact as implied by their name, but MCCBs are available in much higher current ratings and come with additional performance features. MCBs are normally available with a current rating of up to 100 amperes, while MCCBs reach up to 2,500 amperes.

You will probably not find MCCBs in small homes and businesses, according to many electrical engineers, but they are common in larger constructions, such as the high rise multi-family and office buildings found throughout larger cities.

Miniature Circuit Breakers

Miniature circuit breakers come in two main versions: DIN-rail mountable MCBs can be installed along with other protection and control devices that also use DIN rails, while plug-in MCBs are inserted on load centers with specially designed slots. Keep in mind that DIN-rail MCBs are designed for standard rails, while plug-in MCBs only fit into matching load centers from the same manufacturer.

Plug-in MCBs have one to three poles, depending on the number of live conductors in the circuit being protected. DIN-rail MCBs can have up to 4 poles, in order to disconnect the neutral conductor along with the live conductors. Regardless of the type of circuit breaker, it is important to select an adequate rated current and breaking capacity.

  • The rated current is determined by the circuit being protected. Any value above this eventually trips the thermal protection mechanism.
  • The breaking capacity is the largest fault current that the unit can interrupt without suffering permanent damage. Should a fault exceed this value, there is an ultimate breaking capacity where the breaker can still clear the fault but is permanently damaged. Any fault above the ultimate breaking capacity cannot be cleared by the circuit breaker, and must be handled by a higher capacity protection system connected upstream.

Miniature circuit breakers are also classified into three types based on their response to fault currents: Type B, C and D. The type determines the threshold where the magnetic protection takes over the thermal protection, causing an instantaneous trip.

Molded Case Circuit Breakers

MCCBs are bulkier than MCBs and are available with higher current ratings. Many models also feature adjustable trip settings, allowing a very accurate protection response if a specific load needs it.

Some MCCBs also come with a removable trip unit that can be replaced with a smaller capacity unit, to recondition the breaker for a load with reduced current. However, you cannot upgrade to a larger trip unit that exceeds the frame size of the MCCB.

There are modern MCCBs that do not use the conventional thermal-magnetic mechanism, but instead use an electronic circuit that measures current and simulates the trip response. This allows a very precise adjustment of protection settings.

Two subtypes of MCCB are designed specifically for the protection needs of electric motors: Motor protection circuit breakers (MPCB) and motor circuit protectors (MCP). The main difference is that an MPCB includes both thermal and magnetic protection, while an MCP only comes with magnetic protection and needs an external overload relay to offer full protection.

Conclusion

Electrical engineers must select the right type of circuit breaker, as it is very important to ensure the safe operation of building systems that include electrical components. Undersized breakers trip continuously and disrupt equipment operation, while oversized breakers do not provide reliable protection against overload current. If an overload is not interrupted, the heating effect can damage conductor insulation and eventually cause a ground fault or short circuit.

Top searches related to Sprinkler Engineering The Island Chicago, IL.

Mechanical Engineers

(MEP) Engineering Service in The Island Chicago

MEP Firm The Island Chicago! When you re looking for a competent MEP Chicago in Firm? The top choice is is New York Engineers. Not only for MEP Chicago but also Construction Engineering and Sprinkler Engineering near The Island Chicago. Contact us at 312 767-6877 A great number of general contractors throughout Yonkers, NY have come to rely on NY Engineers for a wide range of engineering services ranging from Electrical [...]