Searching for the best MEP Chicago? The one to go to is New York Engineers. Not only for MEP Firms in Chicago but also Construction Engineering and Sprinkler Engineering near West Chesterfield Chicago. Contact us at (312) 767-6877

Contact Us
HVAC Mechanical Engineer

Developers throughout Cheektowaga, NY have come to rely on NY-Engineers.Com for a wide range of engineering services ranging from Fire Protection Engineering to Value Engineering. That is why property owners in West Chesterfield Chicago will tell you that if you’re searching for a excellent MEP Engineering firm in West Chesterfield Chicago, Illinois you should consider NY-Engineers.Com.

It is very possible, you have walked through any specific sort of building and observed the results of MEP Engineering. Basically, MEP concentrates on the mechanical, electrical and plumbing aspects of engineering. In essence, MEP already gives rise to the most frequent and precise notion of what is MEP. Our article goes into some specifics of what is MEP Engineering.

So far as the mechanical side is concerned, for residential and commercial engineering, this handles anything which moves. Additionally its involves the usage of complex and simple machines and also other mechanical mechanisms to execute certain tasks. Some everyday mechanical engineering jobs which is often noticed on a day to day bacis are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems that handle improving the energy productivity.

The electrical part of construction is focused on the electrical safety, functions, components, and more importantly, the wiring associated with a building. Engineers within this branch go to great lengths to make sure that the schematics of any building are created to supply enough electricity to each individual component in a safe manner ensuring that all the electrical codes are followed. Some familiar electrical engineering jobs are available in the lighting design, regulating the voltage and allocating the energy to each and every component inside the building that requires a supply.

So far as plumbing, there may be a wide array of plumbing factors that make up the final design of any structure. Plumbing engineering goes deeper than just faucets, toilets, and sinks, and houses several behind the scene appliances. These being the sewage and drainage lines as well as the buildings domestic water supply and how it flows.

As we wrap up our article we certainly have just reviewed what is MEP Engineering. MEP Engineering is administered within the construction industry. And, assists in completing the often ignored technical facets of any building.

Hiring an MEP Engineering Firm in West Chesterfield Chicago is Important for Huge Construction Projects

Hiring an MEP engineering firm in Auburn Gresham Chicago, Illinois, could have a whole lot to do with the success of your construction project. These engineers might help offset the cost of making this sort of hiring decision in terms of energy saving alone. While you are referring to big commercial structures, energy saving is a vital topic of discussion. It’s time to determine various other great reasons behind using MEP engineering firm in East Garfield Park Chicago, IL.

Engineers have everything to do with the physical integrity of a building. As you may well imagine, this means the hidden is very vital. Design not merely deals in aesthetics but the underpinning of a building also its mechanism. That may be yet another solid good reason that using an MEP engineering company will probably be useful to any project.

Think of all of the pipes and plumbing. Take into account the cooling and heating systems and how important it is to get each one of its components in the correct places. Energy conservation was stated, however energy competence can be another important term to note. Energy competence is related to your HVAC system, plus it plays a huge part in energy saving as a whole.

Consider your building’s footing. Consider the installation of security alarms and the security and safety measures put in place along the entire structure. With everything else discussed so far, it’s safe to say that numerous facets of building construction may be either overlooked or minimized without MEP experts at the job.

Now with all you have read you will look to find the best MEP engineering firm available, right? It is very obvious that this best engineers have to be in the large scale building of commercial buildings. Personalized may be the best term to work with to describe the way in which these pros will covert a construction job to meet the needs of the operations. There is a great possibility you would like additional info about the MEP Engineering services in West Chesterfield Chicago, Illinois by NY-Engineers.Com you should visit at our blog.

Latest Plumbing Engineering Related Blog Post

Electrical Safety and Power Quality: A Short Guide for Electrical Engineering

Electricity is one of the cornerstones of modern society, but it can be very dangerous if handled incorrectly. Therefore, governments have introduced stringent codes to regulate its use and ensure safety for occupants. A building’s power supply must be safe to use, and it must also have the voltage and frequency required by the electrical appliances in the building. The electrical engineering systems that provide electrical safety and power quality are typically hidden from sight, but they play a fundamental role in buildings.

Electrical issues are more common in pre-war apartment buildings and other old constructions. Always make sure you get the installation checked before moving into an existing property, but especially if it very aged.

Electrical Protection Devices

The main function of electrical protections is to disconnect the power supply when dangerous operating conditions are present. The main types of electrical faults found in electrical engineering systems are the following:

  • Overload or overcurrent
  • Short circuit
  • Ground fault
  • Line-to-line fault
  • Transient or voltage surge

Plug-in circuit breakers are perhaps the best-known electrical protection devices, commonly used in residential and light commercial applications (below 100 Amperes). Molded-case circuit breakers are generally larger and reach higher current ratings, while motor circuit protectors and thermal overload relays are designed for the protection needs of electric motors. Other than the plug-in configuration, there are protection devices designed for a DIN rail mount or for bolted connections.

An overload occurs when an electrical circuit is drawing current above its rated value for an excessively long period. It is important to note that short-duration overcurrent is common in some types of equipment. For example, three-phase electric motors may draw up to eight times their rated current during startup, but only for a short time – typically fractions of a second. Some types of lighting also draw an inrush current, especially if they have ballasts.

Circuit breakers typically use a thermal interruption mechanism to protect circuits from overload while allowing short-duration current peaks. The thermal protection mechanism uses a metallic contact that expands when heated by current, and it is calibrated to allow the circuit breaker’s rated current but not higher values. However, since inrush currents occur too quickly, their heating effect is not enough to expand and disconnect the thermal protection mechanism. On the other hand, an overload eventually trips the breaker; as current magnitude increases, the thermal protection contact expands faster and disconnects the circuit in less time.

A short circuit occurs when a live conductor touches a neutral conductor, causing a very high current. The magnitude of a short circuit fault is very high, typically thousands of amperes, so it must be disconnected as quickly as possible. In this case the response of thermal protection is too slow, so the protection mechanisms that clear short circuit faults are based on electromagnetic induction – the intense current induces a strong magnetic field that disconnects the circuit breaker.

A ground fault, also known as a line-to-ground fault, occurs when a live conductor touches a conductive element that is not part of the electric circuit. This also creates a very high current due to the low contact resistance, activating the magnetic protection mechanism of the respective circuit breaker. A line-to-line fault occurs when two live conductors at different voltage touch each other, also causing a high-magnitude current. In both cases, the same magnetic protection mechanism that clears short circuit faults responds and trips the circuit breaker.

All the faults described above are characterized by excessive current. When a high voltage peak occurs, the fault is called a transient or a voltage surge. Voltage surges normally occur when large equipment is switched, and can also be caused by lightning. Since circuit breakers are not designed to protect installations from voltage surges, you must use a surge protection devices (SPD) or transient voltage surge suppressor (TVSS). One of the most common types of TVSS use a variable resistance (varistor) connected between the live conductors and the ground – its resistance is high under normal operating conditions, but drops to a very low value in response to voltage peaks, discharging the fault to the ground before it reaches sensitive equipment.

Improving Power Quality in Electrical Engineering Systems

Electric power systems may also suffer from issues that are not faults strictly speaking, but which are also detrimental for performance. Two of the main issues are low power factor and harmonics.

Power factor is a very abstract concept, but the following is a simple way to visualize it. Some types of electrical equipment draw current in such a way where not all the power drawn from the voltage supply is really consumed. In these cases, the term “real power” is used to describe the power that is actually used, and the term “reactive power” is used to describe the portion that oscillates back and forth between the equipment and the power supply without being used. Some of the most common loads associated with reactive power are electric motors, transformers and ballasts. The power factor is the ratio of the real power used and the apparent power – the direct multiplication product of voltage and current.

  • Assume a single-phase motor consumes 900 W of electric power while drawing 5 amperes at 240 volts.
  • The apparent power is 1,200 volt-amperes (240V x 5A).
  • The power factor is 0.75 (900W / 1200 VA). It can also be reported as 75%.
  • The maximum possible value is 1.00 or 100%, where all the power drawn from the voltage source is consumed. Purely resistive loads such as incandescent lamps and resistance heaters behave this way.

Low power factor increases the current drawn by a building, and this creates an extra burden for the grid. Therefore, utility companies typically penalize users that allow their power factor to drop below a specified value. Low power factor is corrected by installing capacitors, which are similar to batteries but designed for a much faster cycle – the oscillating current that characterizes reactive power is supplied locally by the capacitor, and not drawn from the power grid, sparing the user from extra charges.

Power factor correction is characterized by its quick payback period, typically less than one year.

Harmonics are voltage and current signals whose frequency is a multiple of the service frequency – 60 Hz in the USA. Harmonics are produced by nonlinear loads such as magnetic cores and digital equipment, and they tend to overheat circuits, especially the neutral conductor. Excessive harmonics can also cause some types of electronic equipment to malfunction. Harmonic filters are devices that are tuned for a specific harmonic frequency, and when installed in a power system they prevent the propagation of harmonics beyond the equipment that generates them.

Conclusion

The best recommendation to keep all these electrical issues under control is to seek professional assistance from an electrical engineering profession. In new constructions, protection and power quality can be addressed from the design stage. For existing buildings, power monitoring equipment can be used to detect harmonics or low power factor, and the measurement results are then used to specify harmonic filters and capacitors. If circuit breakers are tripping frequently, get an inspection to determine the cause: there could be an electrical fault, but the breaker itself could also be damaged.

Common searches related to Utility Filings West Chesterfield Chicago, IL.

HVAC Engineers Near Me

(MEP) Engineering Service in West Chesterfield Chicago

MEP West Chesterfield Chicago! If you're looking for a fast responding MEP Engineering in Chicago? Your best bet is to reach out to is New York Engineers. Not only for MEP Firms in Chicago but also Mechanical Engineering and Sprinkler Design Engineering in or near West Chesterfield Chicago. Call us at (+1) (312) 767.6877 Quite a few developers throughout Ronkonkoma, NY have come to rely on NY-Engineers.Com for a wide range [...]