MEP Service in West Morgan Park Chicago, IL.

Contact Us

In search of a top rated MEP Firms in Chicago? Your best bet is to call is NY Engineers. Not only for MEP Chicago but also Architectural Engineering and Sprinkler System Engineering throughout West Morgan Park Chicago. Contact us at (+1) 312 767.6877

Contact Us
Value Engineering

Real estate investors throughout Kingston, New York have come to rely on NY-Engineers.Com for a wide range of engineering services ranging from Fire Protection Engineering to Building Commissioning. For this reason property owners in West Morgan Park Chicago will tell you that if you’re looking for a excellent MEP Engineering firm in West Morgan Park Chicago, Illinois you should consider NY Engineers.

Chances are, you have walked through any particular form of building and observed the outcome of MEP Engineering. To put it simply, MEP centers in the mechanical, electrical and plumbing areas of engineering. In simple terms, MEP already gives a clue to the most typical and correct notion of precisely what is MEP. Our article may go into some information on what is MEP Engineering.

So far as the mechanical side is concerned, for both residential and commercial engineering, this works with anything that moves. Furthermore its involves the application of complex and uncomplicated machines as well as other mechanical mechanisms to do certain tasks. Some normal mechanical engineering jobs that can be noticed regularly are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems that cope with improving the energy efficiency.

The electrical part of construction is focused on the components, functions, electrical safety, and even more importantly, the wiring associated with a building. Engineers in this sector try very hard to make sure that the layout of the building are created to bring enough power to each individual component in a safe manner where every one of the electrical codes are followed. Some familiar electrical engineering functions may be found in the lighting design, modifying the voltage and allocating the energy to every component within the building which requires a supply.

So far as plumbing, there is certainly a variety of plumbing factors which make up the final design of any structure. Plumbing engineering goes deeper than simply toilets, faucets, and sinks, and holds several behind the scene equipments. These being the drainage line and sewage plus the buildings domestic water supply and just how it flows.

As we conclude this article we certainly have just considered what is MEP Engineering. MEP Engineering is administered in the construction industry. And, supports completing the easily overlooked technical aspects of any building.

Hiring an MEP Engineering Firm in West Morgan Park Chicago is Necessary for Huge Construction Projects

Hiring an MEP company in Old Town Chicago, Illinois, may have a whole lot to do with the prosperity of your construction project. These specialists will help offset the fee for making this type of hiring decision in relation to energy upkeep alone. When you find yourself talking about large commercial buildings, energy management is a crucial topic of discussion. It’s time to determine some other great reasons behind hiring MEP firm in Beverly Woods Chicago, IL.

Engineers have everything to do with the structural reliability of any building. If you can well envision, it means the hidden is very important. Design not merely deals in aesthetics but the foundation of a building also its mechanism. That may be just another solid good reason that hiring an MEP engineering firm will probably be useful to your project.

Consider every one of the pipes and plumbing. Think about the heating and cooling systems and how important it is to get all its mechanics in the right places. Energy saving was mentioned, but energy efficiency is another important term to bring up. Energy competence has everything to do with your HVAC system, plus it plays a huge role in energy conservation as a whole.

Think about your building’s foundation. Consider setting up security systems and the safety and security measures put in place throughout the structure. With everything else discussed to date, it’s reliable advice that a great many elements of building construction might be either ignored or underestimated short of MEP engineers on the job.

Now with all you know you will be looking for the best MEP engineering company in the market, right? It is pretty clear the best engineers have to be working in the large construction of commercial buildings. Personalized is definitely the proper term to use to illustrate the way in which these specilists will customize a construction job to meet the needs of your own operations. There is only so much you can save this page if you would like additional details about the MEP Engineering services in West Morgan Park Chicago, IL by NY-Engineers.Com you should visit at our blog.

New Building Commissioning Related Article

An MEP Engineers’ Guide to Air Dampers

Construction Engineering Vs Civil Engineering

An air damper is a device that uses valves or plates to stop or regulate the flow of air within a duct, chimney, variable-air-volume (VAV) box, air-handling unit or other similar pieces of equipment. Dampers are also used to stop airflow into unoccupied or unused rooms where air conditioning is not required. In addition, MEP engineers install dampers as protection measures against smoke or fire.

An air damper is a complex mechanism with many moving elements. Their main components are the blades, which adjust their position to control airflow. In addition, dampers include frames, linkages, axles, bearings, seals, blade pins, actuating motors, flanging, jackshafts, and sleeves, among other components.

Types of Air Dampers

Based on their construction, air dampers can be classified into parallel blade and opposed blade dampers. Each configuration has unique performance features and is intended for different applications.

1) Parallel Blade Dampers

In this type of air damper, blades rotate in the same direction, parallel to one another. The parallel blade configuration is typically used when the damper operates in two positions: open or closed.

These dampers redirect air flow along their first few degrees of rotation, as they move from fully open to closed, and therefore control is achieved along the first 20-30% of movement.  Rather than modulating air streams, these dampers change their direction, and that is the main reason why they are preferred for open-close operation or fixed flow control.

Parallel blade dampers are typically used by MEP engineers in applications where the damper represents a major portion of the overall system pressure loss. They should not be used upstream of critical components due to their uneven airflow.

2) Opposed Blade Dampers

In this type of air damper, blades rotate in opposite directions to one another, modulating airflow. These air dampers are mostly used when the system requires airflow control rather than open-close operation, but they can also be used for on-off service.

Opposed blade dampers are typically used in the following applications:

  1. When the damper doesn’t represent a major portion of the overall system pressure loss.
  2. Systems that are required to maintain an even airflow downstream from the damper.
  3. Ducted terminals.

Classification of Dampers by Control Method and Application

Air dampers can also be classified based on the control method they deploy and their intended application. Based on their control method, dampers can be either automatic or manual:

  • Automatic dampers are similar to automatic control valves in terms of functioning.
  • Manual dampers are adjusted manually depending on the required airflow, as implied by their name.

Dampers can also be classified based on their application, and the following are some of the main types:

  • Balancing dampers (volume dampers)
  • Face and bypass dampers
  • Fire dampers
  • Smoke dampers
  • Combined fire and smoke dampers
  • Gravity dampers (backdraft or barometric)
  • Mixing dampers
  • Multi-zone dampers
  • Round dampers
  • VAV boxes (variable-air-volume)

Note how dampers are not only used for air balancing in ventilation systems, but also for safety in fire protection applications.

Why Are MEP Engineers Concerned About Dampers?

Air dampers are an important element of MEP engineering design since their use is subject to code requirements. They should also be designed to minimize energy losses, through the prevention of heat exchange across them when in the closed position, all while maintaining the required pressure conditions in different spaces.

Air dampers are subject to the following codes and standards:

  1. National Fire Protection Association (NFPA) standards:
    1. NFPA 90A Standard for the Installation of Air-Conditioning and Ventilating Systems
    2. NFPA 92A Standard for Smoke-Control Systems Utilizing Barriers and Pressure Differences
    3. NFPA 101 Life Safety Code
  2. Underwriters Laboratories (UL) standards:
    1. UL 555 Standard for Fire Dampers
    2. UL 555S Standard for Smoke Dampers
    3. UL 555C Standard for Ceiling Dampers

The main locations where air dampers are required to meet code are the following: stair enclosures, elevator shafts, common corridors, mechanical rooms, fire-rated walls, exterior building walls, shaft enclosures, horizontal assemblies, and duct and transfer openings.

Air Dampers in Fire Protection Applications

The three main types of dampers used in fire protection applications are fire dampers, smoke dampers, and combined fire/smoke dampers. This section provides an overview of each type and its applications.

Fire Dampers

Fire dampers interrupt airflow through the duct automatically, restricting the passage of flames. To accomplish their function, these dampers are installed in ducts that cross fire-rated assemblies or fire-rated walls. They can be installed in both horizontal and vertical ductwork and can be of both curtain type and multi-blade type.

A fire damper has the following components:

  1. Sleeve
  2. Curtain blade
  3. Break-away joints
  4. Fusible link
  5. Access door to inspect the fire damper

All fire dampers are installed in the open position, with a fusible link. When the temperature in the ductwork exceeds a specified value, the fusible link melts and the damper gets shut off, either by gravity or by a spring. To guarantee they accomplish their function, fire dampers need to pass various tests.

Fire damper selection is based on three main factors: fire resistance rating, temperature, and operating range. Fire rating depends on the time span for which a damper will withstand the heat associated with a fire. For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire dampers are used. This procedure ensures building code compliance, which requires that the fire resistance rating is maintained across the full area of walls, partitions, and floors.

The exceptions for the use of fire dampers are parking garages, kitchen exhaust ductwork, and dryer exhaust ductwork.

Smoke Dampers

Smoke dampers prevent smoke from spreading in HVAC systems that are designed to shut down automatically in case of fire, and they only have two positions: open and closed. These dampers are installed in a slotted duct section – they are installed whenever a duct penetrates a smoke partition or smoke barrier inside the building. They can be applied in passive smoke control systems, or as part of an engineered smoke control solution.

In passive systems, smoke dampers close and prevent the circulation of air and smoke through ducts or ventilation openings that cross a smoke barrier. On the other hand, in engineered smoke control systems, the spread of smoke is controlled by the building HVAC system or by dedicated fans that create pressure differences. Smoke dampers may be controlled by heat sensors, smoke sensors, fire alarms, or any other method that meets the design intent.

A smoke damper has the following components:

  1. Sleeve
  2. Smoke blades (parallel)
  3. Break-away joints
  4. Duct-mounted smoke detector
  5. Damper actuator
  6. Access door

It is important to decide which ratings are required for UL Listed fire dampers.

  • The SD-1320 and SD-1330 smoke dampers are UL/cUL leakage rated dampers, listed under the latest UL 555S standard.
  • SD-1620 smoke dampers meet UL Class II. Leakage is less than 20 cfm per square foot at 4 inch w.g. and at 350°F (177°C).
  • SD-1630 smoke dampers meet UL Class I. Leakage is less than 8 cfm per square foot at 4 inch w.g. and at 350°F (177°C).

Fire and Smoke Damper (Combined)

As implied by its name, this type of damper is a combination of a fire damper and a smoke damper, and it is installed in ducts that cross partitions rated as both fire and smoke barriers. This type of damper must be qualified under both UL555 and UL555S.

Selection of a combined fire and smoke damper depends upon 4 factors: fire resistance rating, leakage rating, temperature and operational ratings.

Combined fire and smoke damper applications include walls, floors, partitions required by the local building code.

For walls, partitions, and barriers with fire resistance rating of less than 3 hours, 1.5-hour fire/smoke dampers are used. For fire barriers rated for 3 hours or more, 3-hour fire/smoke dampers are used. Designers are usually suggested to pick a very low leakage category.

Conclusion

Air dampers have a wide range of applications, ranging from airflow modulation in normal operating conditions to providing a reliable barrier against smoke or fire during emergencies. However, code compliance is an important aspect to consider regardless of the application, so working with qualified MEP engineers is highly recommended.

Common searches related to Sprinkler Engineering West Morgan Park Chicago, IL.

What Do Mechanical Engineers Do

(MEP) Engineering Service in West Morgan Park Chicago

MEP Engineers West Morgan Park Chicago! If you re searching for a reliable MEP Engineering in Chicago? The one to go to is is New York Engineers. Not only for MEP Chicago but also Architectural Engineering and Sprinkler System Engineering near West Morgan Park Chicago. Call 312 767-6877 Quite a few building owners throughout Harrison, NY have come to depend on NY-Engineers.Com for a wide range of engineering services ranging from [...]