MEP Service in Wrigleyville Chicago, Illinois.

Contact Us

Searching for a top MEP Firms in Chicago? The one to go to is New York Engineers. Not only for MEP Engineering in Chicago but also Architectural Engineering and Sprinkler Design Engineering throughout Wrigleyville Chicago. Call us at (+1) (312) 767.6877

Contact Us
HVAC Engineering Companies

Property owners throughout Mineola, NY have come to depend on NY Engineers for a wide range of engineering services ranging from Sprinkler Engineering to Utility Filings. This is why developers in Wrigleyville Chicago will tell you that if you’re searching for a top-rated MEP Engineering firm in Wrigleyville Chicago, IL you should consider New York Engineers.

Odds are, you might have walked into any specific sort of building and saw the results of MEP Engineering. In other words, MEP focuses in the mechanical, electrical and plumbing facets of engineering. In essence, MEP already gives a clue to the most common and correct notion of what is MEP. This article should go into some details of what is MEP Engineering.

As far as the mechanical aspect is concerned, both for commercial and residential engineering, this deals with anything that moves. Additionally its involves the usage of complex and simple machines as well as other mechanical mechanisms to perform certain tasks. Some common mechanical engineering jobs that may be noticed regularly are kitchen or bath exhausts, HVAC units, cooling and heating air systems, heating & cooling equipment and systems which deal with improving the energy efficiency.

The electrical aspect of construction is focused on the components, functions, electrical safety, and more importantly, the wiring of any building. Engineers in this sector try very hard to make sure that the schematics of any building are meant to deliver ample power to every individual component in a safe manner where every one of the electrical codes are met. Some common electrical engineering tasks can be found in the lighting design, modifying the voltage and distributing the power to every component in the structure that needs a supply.

plumbing, there may be a variety of plumbing factors that make up the final design of any structure. Plumbing engineering goes deeper than just faucets, toilets, and sinks, and contains many behind the scene appliances. These being the drainage line and sewage and also the buildings local water supply and the way it flows.

As we wrap up our article we now have just reviewed what is MEP Engineering. MEP Engineering is administered within the construction industry. And, aids in completing the often unnoticed technical elements of any building.

Hiring an MEP Engineering Firm in Wrigleyville Chicago is Necessary for Huge Construction Projects

Using an MEP company in Lithuanian Plaza Chicago, Illinois, may have everything to do with the safety of your construction project. These professionals will help offset the price of making this type of hiring decision when it comes to energy upkeep alone. While you are talking about huge commercial buildings, energy upkeep is really a topic of discussion. It’s time to find out some other great factors behind using MEP company in Edgewater Beach Chicago, Illinois.

Engineers have a lot to do with the structural integrity of your building. If you may well envision, that means the unseen is extreamly essential. Design not merely deals in aesthetics but the foundation of a building including its mechanism. That is merely another solid reason why using an MEP engineering firm will probably be useful to any project.

Think of every one of the pipes and plumbing. Look at the air conditioning systems and how important it is to get each one of its mechanics in the exact places. Energy maintenance was discussed, but energy competence can be another important term to note. Energy competence is about your HVAC system, plus it plays an important role in energy saving in general.

Take into consideration your building’s shell. Consider installing security alarms along with the security and safety measures put in place through the structure. With everything discussed up to now, it’s safe to say that numerous elements of building construction might be either overlooked or minimized short of MEP professionals at work.

Now with all you know you are going to be looking for the best MEP engineering firm in the market, right? It’s very clear the best engineers need to be active in the massive construction of commercial structures. Tailor made is the proper term to use to illustrate how these experts will modify a construction job to meet the needs of your respective operations. There is only so much you can save this page if you would like more details about the MEP Engineering services in Wrigleyville Chicago, Illinois by New York Engineers we invite you to visit at our Wrigleyville Chicago Mechanical Engineering blog.

Construction Administration Related Post

Selecting the Right Type of Electrical Raceway for your Architectural Engineering Project: Nonmetallic Conduit Options

MEP Consulting Engineers Reviews

Our previous article covered the main types of metallic conduit for electrical conductors, and now we will discuss nonmetallic conduit and its applications in architectural engineering and other engineering areas. Nonmetallic conduit is normally the more affordable option, providing improved electrical isolation and corrosion resistance, while reducing the degree of physical protection.

Like with metallic conduit, all electrical installations must be according to the NFPA National Electric Code and local electrical codes. Conductors are not intended for unprotected installation, except for specific types that include metallic armor or polymer sheathing.

Keep in mind that this article is no replacement for electrical codes; the technical information provided here is very general. When working with engineering projects that involve electrical installations, you should check the specific code requirements for each application.

Rigid Polyvinyl Chloride Conduit (PVC)

PVC is possibly the most common type of nonmetallic conduit used in architectural engineering projects, being lightweight and affordable, while offering decent mechanical resistance for its low weight. In addition, it is virtually unaffected by humidity and corrosion, and is also an electrical insulator. However, the insulating properties of PVC are both a benefit and a disadvantage: the conduit itself cannot be electrified, but a grounding conductor becomes mandatory as a result, while metallic conduit can be used as both raceway and grounding in various applications.

PVC also offers features that simplify installation: it can be heated for quick manual bends, recovering its rigidity once it cools down. In addition, its low weight simplifies handling, and the conduit is easy to cut. PVC fittings are unthreaded and designed for slip-on installation, using solvent cements. PVC pull boxes also bring the reduced weight advantage, making them easier to handle and install.

This type of nonmetallic conduit is available with three different wall thicknesses: Schedule 20 is the thinnest, Schedule 40 is intermediate, and Schedule 80 is the thickest. Trade sizes range from ½” to 6”.

  • Schedule 20 PVC, with its thin walls, is not approved by the NEC for electrical installations. Therefore, it is used mostly in communication systems.
  • Schedule 40 PVC is the general-purpose option, adapting to a wide range of applications.
  • Schedule 80 PVC is used there conduit is exposed to physical damage. It is more expensive than Schedule 40, but its added strength increases the allowed applications.

The use of PVC conduit is not allowed in hazardous locations, areas where the ambient temperature exceeds 50°C (122°F), or applications where conductor insulation temperature exceeds the rated temperature of PVC. When used for lighting circuits, PVC cannot be used as physical support to hang lighting fixtures. Although the code does not prohibit its use with low ambient temperatures, consider that extreme cold can make PVC brittle, offering reduced protection for conductors.

High Density Polyethylene Conduit (HDPE)

HDPE is a type of nonmetallic conduit for applications where the circuit is buried or encased in concrete. It is not approved for indoor use or for exposed installation. Like PVC conduit, HDPE is not allowed in hazardous locations unless the code makes a direct exception, and it subject to the same ambient temperature and conductor insulation temperature limitations. The approved HDPE trade sizes range from ½” to 6”.

Reinforced Thermosetting Resin Conduit (RTRC)

RTRC is more commonly known as fiberglass conduit. Its applications are very similar to those of Schedule 40 PVC, but there is one key advantage: PVC can become brittle when exposed to very cold weather, while RTRC conserves its mechanical properties. RTRC is suitable for exposed or buried installation, indoor or outdoor use, and is unaffected by humidity and corrosion.

The applications where RTRC is not allowed are similar to those of Schedule 40 PVC: hazardous locations, luminaire support, and areas where it is exposed to physical damage or high temperature. Like with PVC and HDPE, trade sizes range from ½” to 6”.

Liquidtight Flexible Nonmetallic Conduit (LFNC)

LFNC has a self-explanatory name: it is a type of nonmetallic conduit intended for connections and cable runs with obstacles that are difficult to bypass with rigid conduit. LFNC is a versatile option, approved for various indoor and outdoor applications. Usage is not allowed where it will be exposed to damage, in hazardous locations, or if temperatures exceed conduit ratings. Like PVC, LFNC is vulnerable to extreme cold: it may become brittle, losing its flexibility. Unless codes make an exception, LFNC should not be used in runs longer than 6 ft or with circuits above 600V. Approved trade sizes range from ⅜” to 4”.

Electrical Nonmetallic Tubing (ENT)

ENT has similar applications to LFNC, but can be used for runs longer than 6 feet. In indoor locations, ENT can be either exposed or concealed. It resists moisture and corrosion, but can only be used outdoors if encased in concrete or protected from sunlight. Direct burial is not allowed, and it can only be installed exposed to the sun if specified as sunlight resistant.

ENT trade sizes range from ½” to 1”, and it is subject to the same usage restrictions that apply for many other types of nonmetallic conduit: hazardous locations, high temperatures and luminaire support.

Additional Recommendations from an Architectural Engineering Professional

Although each application is unique, non-metallic conduit generally offers a cost advantage over metallic conduit, giving up on some physical protection. However, keep in mind that metallic conduit may be mandatory in various architectural engineering applications; for example, the most demanding environments typically require rigid metal conduit (RMC) or intermediate metal conduit (IMC).

To achieve the best results in electrical installations, working with qualified professionals is highly recommended. In new construction, you can achieve drastic cost reductions with smart design decisions. For example, energy efficiency reduces the electrical load, which in turn reduces conductor and conduit diameter.

searches related to Energy Modeling in Wrigleyville Chicago, Illinois.

Best MEP Engineering Firms

(MEP) Engineering Service in Wrigleyville Chicago

MEP Engineers Wrigleyville Chicago! If you re looking for a reliable MEP Engineering in Chicago? The top choice is is NY Engineers. Not only for MEP Engineering in Chicago but also Architectural Engineering and Sprinkler Engineering in Wrigleyville Chicago. Call (312) 767.6877 The great majority of developers throughout Holbrook, New York have come to depend on NY Engineers for a wide range of engineering services ranging from Sprinkler Engineering to Energy [...]

2018-09-10T06:01:57+00:00