Electrical Engineer Service Hackensack New Jersey2019-03-02T01:02:42+00:00

Electrical Engineer Services in  Hackensack New Jersey

Construction Engineering Vs Civil Engineering

From California to Vermont developers have come to rely on NY Engineers when they need expert MEP Engineers in or near Hackensack New Jersey. However, it is vital to highlight that New York Engineers is more than that! We’re eight national engineering agency offering not only design but also consultation services. Even though we are focused on mechanical, electrical and plumbing (MEP) installations. New York Engineers offers a range of services to property developers and business owners. These services range from designing mep systems of adequate capacity according to building conditions, meeting the specific needs of each client to project management and commissioning, ensuring all systems are installed and configured according to the approved design documents and more. In the last few years we have seen a considerable for Electrical Engineering Services in Hackensack New Jersey. That is yet another discipline where NY Engineers excels at!

Why you ought to consider MEP.NY-Engineers.Com for all your electrical engineer needs? If you’re in the course of planning a huge project, and the project requires electrical work, you may want to think about hiring an electrical engineer. You may also want to examine calling in a pro if you have electrical problems that you are attempting to solve. Why should you be hiring a professional? Below are a couple of the perks you’ll have the capacity to enjoy if you deal with an expert.

They’ll Allow You To Avoid Huge Blunders – It’s not unusual for anyone to make mistakes in terms of electrical work. Sadly, these types of errors might have harmful outcomes. You’ll want to work alongside someone that’s mindful of anything that could go wrong. In the event you hire someone with all the right expertise, they’ll be able to ensure that the assignment that you’re planning, goes off without having a hitch.

They Could Provide Lots Of Useful Advice – You will possibly not have much knowledge about electrical work. Thankfully, these professionals have lots of knowledge that you don’t. They’ll have the capacity to give feedback and advice that might be truly necessary to you. Should you wind up utilizing someone similar to this, you’ll end up taking a great deal of their comments aboard.

They Can Aid You To Complete A Project On Schedule – Plenty of projects like this end up getting delayed, and these types of delays can be extremely costly. If this sounds like something which you’d prefer to prevent, a specialist will be able to make sure that you won’t go off your schedule.

There are numerous reasons to take into account hiring an electrical engineer. If you’re arranging a major project, and you think that you might use an engineer, you should start conversing with some professionals that happen to be within your general area. At NY Engineers, we have been able to help thousands of real estate developers who were searching for Electrical Engineering Services in or near Hackensack New Jersey with not only that but also services such as CAD to Revit Modeling Engineering Services. If you would like additional info on the services offered by New York Engineers please, visit on our blog.

New Blog Post Related to Electrical Engineer Services in Hackensack New Jersey

Advantages of Electronically Commutated Motors in Electrical Engineering

Value Engineering Ppt

Electronically commutated motors (ECMs) can achieve significant energy savings in electrical engineering applications where fractional horsepower is required. Although NEMA Premium Efficiency motors with variable-frequency drives provide the most efficient solution to drive equipment above 1 hp, induction motors are outclassed by ECMs as the rated horsepower is reduced.

What is an Electronically Commutated Motor?

Although ECMs are designed to run with an AC power supply, it is important to note they are actually direct-current motors with permanent magnets on their rotor. Unlike conventional DC motors, which create a rotating magnetic field with a combination of brush contacts and slip rings, ECMs achieve the same effect with a voltage rectifier and an electronic control circuit. As a result, the friction and sparks associated with brush contacts are eliminated, and this is one of the reasons why ECMs are so efficient. They also have a longer service life than brushed motors, since the wear associated with sparks and friction is eliminated. Compared with other common types of fractional horsepower motors, ECMs are the top choice in terms of efficiency:

  • Shaded-pole motors are very common and more affordable, but their efficiency is very poor, going below 20% in some cases.
  • Permanent-split capacitor (PSC) motors have an average efficiency of 40%, which means they outclass shaded-pole motors. In terms of efficiency, they are an intermediate option between shaded-pole motors and ECMs.
  • ECM efficiency is normally above 60%, which means they consume one-third of the energy used by shaded-pole motors on average.

ECMs can also be manufactured with built-in speed control circuits, allowing them to operate at reduced speed without relying on an external VFD. It is also important to note that ECMs do not suffer a drastic reduction in their efficiency when operating below rated RPM. Fixed-speed ECMs are also available for applications where speed control is not necessary.

Electronically Commutated Motors in Electrical Engineering Applications

ECMs are normally the most efficient option in fractional horsepower applications, but they tend to deliver the highest savings when used in air-conditioning and refrigeration systems. Being more efficient that shaded-pole and PSC motors, they also dissipate less heat, and the reduced heating effect helps AC and refrigeration systems operate more efficiently. This effect applies for all air-conditioning or refrigeration components that are found inside the conditioned space, such as air handlers and evaporators.

As an example, assume a cold-storage room has an evaporator unit with five shaded-pole motors, consuming 900W each. They are replaced with ECMs that only consume 300 W each.

  • 600 W are saved per motor, for a total of 3,000 W.
  • However, these 3,000 W are also subtracted from the refrigeration load. If the system operates with a coefficient of performance of 3, an extra 1,000 W of electric power are saved.
  • In other words, this upgrade saves 3 kW in motor power and 1 kW thanks to refrigeration load reduction.

Keep in mind this is just a simple example, and each electrical engineering project requires a detailed analysis to know the exact savings. However, the heating reduction benefit applies for all cases where ECM motors are deployed in air-conditioned or refrigerated locations.

The brushless design of ECMs makes them quieter than their less efficient counterparts, which also provides a comfort advantage. In business applications, the silent operation of ECMs helps employees concentrate better. ECMs are also lighter than other types of fractional horsepower motors, which makes them easier to install.

Electronically Commutated Motors in Ventilation Systems

As previously stated, shaded-pole and PSC motors are inefficient. Also, three-phase motors with VFDs are impractical for fractional horsepower applications, unable to offer the efficiency that characterizes them in larger systems. Ventilation systems represent an excellent opportunity to deploy ECMs, for two main reasons:

  • Fans with fractional horsepower are common, which means they are often driven by shaded-pole or PSC motors.
  • Many fans have intermittent operation, which represents a chance to use ECMs running at reduced speed. For example, running a fan 80% of the time saves 20% of the energy, while running it at 80% speed saves nearly 50%.

ECMs are a highly recommended upgrade for furnace fans, since they can achieve a much more uniform temperature distribution with their speed control, in addition to offering the energy savings that characterize them.

Payback Period of ECM Upgrades

Like with many energy efficiency measures, the financial benefit of an ECM upgrade changes depending on project conditions. The project payback period can only be calculated with precision after a detailed analysis by a professional energy consultant, but in general the following results can be expected:

  • Replacing shaded-pole motors normally yields a faster payback period than replacing PSC motors, since the efficiency gain is higher. Of course, there can be exceptions; replacing a PSC motor that is used frequently may yield higher savings than upgrading a shaded-pole motor that is only used moderately.
  • ECMs can also be an attractive option in appliances that require speed control. Other types of motors may suffer a drastic efficiency reduction at partial speed.
  • As previously mentioned, the energy savings are higher when ECMs are deployed in air-conditioned or refrigerated spaces.

The financial return of an ECM upgrade can also be enhanced if there are incentive programs at the project’s location. The incentive is calculated based on yearly energy savings, at a rate of $0.16/kWh.

Conclusion

Electronically-commutated motors (ECMs) can achieve significant energy savings in fractional horsepower applications, especially when they replace shaded-pole motors. However, like with any energy efficiency upgrade, professional guidance is highly recommended when defining the project scope and specifications.

When upgrading to ECMs, the return on investment is higher in some cases, and it others the payback period may be too long to justify the upgrade. Ideally, upgrades should focus on where the highest return is obtained from each dollar spent upfront. Recruit the help of an electrical engineering expertise to help you properly apply the information shared in this article to your project.

MEP Engineering Firms Near Me