What Do Mechanical Engineers Do

From Connecticut to North Dakota homebuilders have come to rely on MEP.NY-Engineers.Com when they need reliable MEP Engineering Services in Lompoc California. However, it is vital to point out that NY-Engineers.Com is more than that. We’re eight national engineering company offering not only design but also advisory services. Although we are focused on mechanical, electrical and plumbing (MEP) installations. MEP.NY-Engineers.Com offers a wide range of services to property developers and business owners. These services range from compliance with national standards, as well as building codes specific to each state or city. this ensures a quick project approval with local authorities to consulting services for existing buildings, to detect performance issues and promising upgrades. this includes energy efficiency measures and renewable energy systems and more. As of late we have seen a huge for Electrical Engineers in or near Lompoc California. That is an area where we is good at.

Good reasons to hire NY Engineers for your electrical engineer needs? If you are in the process of planning for a major project, and this project calls for electrical work, you might like to consider hiring an electrical engineer. You may also want to check out employing a pro for those who have electrical things that you are looking to solve. Why should you be employing a professional? Here are some of the perks you’ll be capable of enjoy if you deal with an Electrical Engineer.

They’ll Allow You To Avoid Huge Blunders – It’s not uncommon for individuals to make mistakes when it comes to electrical work. Sadly, these kinds of mistakes may have harmful outcomes. You’ll want to do business with someone who is aware about exactly what might go wrong. In the event you hire someone with all the right expertise, they’ll be capable of ensuring that the task that you’re planning, gets completed without a hitch.

They Can Provide A Great Deal Of Useful Advice – You possibly will not have much knowledge of electrical work. Thankfully, these pros have plenty of knowledge that you just don’t. They’ll be able to give feedback and advice which will be truly useful to you. Should you end up utilizing someone similar to this, you’ll realise you are taking a lot of their comments on board.

They Can Aid You To Finish A Project On Schedule – A lot of projects like this find yourself getting delayed, and most of these delays are often very costly. If this is something which you’d prefer to prevent, a specialist are able to make sure that you won’t go off your schedule.

There are numerous reasons to take into account hiring an electrical engineer. If you’re organising a major project, and you think that you can use an engineer, you can start talking to some professionals which can be in your general area. At MEP.NY-Engineers.Com, we have been able to help a great number of building owners who were looking for Electrical Engineering Services in or near Lompoc California with not only that but also services such as Plumbing Engineering. If you would like additional information on the services NY-Engineers.Com we ask that you consider on our blog.

New Blog Related to Electrical Engineer Services in Lompoc California

Selecting the Right Type of Electrical Raceway for your Architectural Engineering Project: Nonmetallic Conduit Options

Electrical Engineering Salary

Our previous article covered the main types of metallic conduit for electrical conductors, and now we will discuss nonmetallic conduit and its applications in architectural engineering and other engineering areas. Nonmetallic conduit is normally the more affordable option, providing improved electrical isolation and corrosion resistance, while reducing the degree of physical protection.

Like with metallic conduit, all electrical installations must be according to the NFPA National Electric Code and local electrical codes. Conductors are not intended for unprotected installation, except for specific types that include metallic armor or polymer sheathing.

Keep in mind that this article is no replacement for electrical codes; the technical information provided here is very general. When working with engineering projects that involve electrical installations, you should check the specific code requirements for each application.

Rigid Polyvinyl Chloride Conduit (PVC)

PVC is possibly the most common type of nonmetallic conduit used in architectural engineering projects, being lightweight and affordable, while offering decent mechanical resistance for its low weight. In addition, it is virtually unaffected by humidity and corrosion, and is also an electrical insulator. However, the insulating properties of PVC are both a benefit and a disadvantage: the conduit itself cannot be electrified, but a grounding conductor becomes mandatory as a result, while metallic conduit can be used as both raceway and grounding in various applications.

PVC also offers features that simplify installation: it can be heated for quick manual bends, recovering its rigidity once it cools down. In addition, its low weight simplifies handling, and the conduit is easy to cut. PVC fittings are unthreaded and designed for slip-on installation, using solvent cements. PVC pull boxes also bring the reduced weight advantage, making them easier to handle and install.

This type of nonmetallic conduit is available with three different wall thicknesses: Schedule 20 is the thinnest, Schedule 40 is intermediate, and Schedule 80 is the thickest. Trade sizes range from ½” to 6”.

  • Schedule 20 PVC, with its thin walls, is not approved by the NEC for electrical installations. Therefore, it is used mostly in communication systems.
  • Schedule 40 PVC is the general-purpose option, adapting to a wide range of applications.
  • Schedule 80 PVC is used there conduit is exposed to physical damage. It is more expensive than Schedule 40, but its added strength increases the allowed applications.

The use of PVC conduit is not allowed in hazardous locations, areas where the ambient temperature exceeds 50°C (122°F), or applications where conductor insulation temperature exceeds the rated temperature of PVC. When used for lighting circuits, PVC cannot be used as physical support to hang lighting fixtures. Although the code does not prohibit its use with low ambient temperatures, consider that extreme cold can make PVC brittle, offering reduced protection for conductors.

High Density Polyethylene Conduit (HDPE)

HDPE is a type of nonmetallic conduit for applications where the circuit is buried or encased in concrete. It is not approved for indoor use or for exposed installation. Like PVC conduit, HDPE is not allowed in hazardous locations unless the code makes a direct exception, and it subject to the same ambient temperature and conductor insulation temperature limitations. The approved HDPE trade sizes range from ½” to 6”.

Reinforced Thermosetting Resin Conduit (RTRC)

RTRC is more commonly known as fiberglass conduit. Its applications are very similar to those of Schedule 40 PVC, but there is one key advantage: PVC can become brittle when exposed to very cold weather, while RTRC conserves its mechanical properties. RTRC is suitable for exposed or buried installation, indoor or outdoor use, and is unaffected by humidity and corrosion.

The applications where RTRC is not allowed are similar to those of Schedule 40 PVC: hazardous locations, luminaire support, and areas where it is exposed to physical damage or high temperature. Like with PVC and HDPE, trade sizes range from ½” to 6”.

Liquidtight Flexible Nonmetallic Conduit (LFNC)

LFNC has a self-explanatory name: it is a type of nonmetallic conduit intended for connections and cable runs with obstacles that are difficult to bypass with rigid conduit. LFNC is a versatile option, approved for various indoor and outdoor applications. Usage is not allowed where it will be exposed to damage, in hazardous locations, or if temperatures exceed conduit ratings. Like PVC, LFNC is vulnerable to extreme cold: it may become brittle, losing its flexibility. Unless codes make an exception, LFNC should not be used in runs longer than 6 ft or with circuits above 600V. Approved trade sizes range from ⅜” to 4”.

Electrical Nonmetallic Tubing (ENT)

ENT has similar applications to LFNC, but can be used for runs longer than 6 feet. In indoor locations, ENT can be either exposed or concealed. It resists moisture and corrosion, but can only be used outdoors if encased in concrete or protected from sunlight. Direct burial is not allowed, and it can only be installed exposed to the sun if specified as sunlight resistant.

ENT trade sizes range from ½” to 1”, and it is subject to the same usage restrictions that apply for many other types of nonmetallic conduit: hazardous locations, high temperatures and luminaire support.

Additional Recommendations from an Architectural Engineering Professional

Although each application is unique, non-metallic conduit generally offers a cost advantage over metallic conduit, giving up on some physical protection. However, keep in mind that metallic conduit may be mandatory in various architectural engineering applications; for example, the most demanding environments typically require rigid metal conduit (RMC) or intermediate metal conduit (IMC).

To achieve the best results in electrical installations, working with qualified professionals is highly recommended. In new construction, you can achieve drastic cost reductions with smart design decisions. For example, energy efficiency reduces the electrical load, which in turn reduces conductor and conduit diameter.

Value Engineering