Electrical Engineer Service Los Banos California2019-03-05T00:01:15+00:00

Electrical Engineer Services in  Los Banos California

MEP Meaning

From Connecticut to New Hampshire construction companies have come to rely on MEP.NY-Engineers.Com when they need reliable MEP Engineers in Los Banos California. However, it is vital to point out that we are more than that. We’re eight national engineering firm offering design but also advisory services. Although we are focused on mechanical, electrical and plumbing (MEP) installations. MEP.NY-Engineers.Com offers a range of services to property developers and business owners. These services range from compliance with national standards, as well as building codes specific to each state or city. this ensures a quick project approval with local authorities to energy efficiency, specifying building systems that accomplish their intended function while saving electricity and fuel and more. Lately we have seen a huge for Electrical Engineering Services in or near Los Banos California. That is an area where NY-Engineers.Com can help you.

Why you need to consider NY-Engineers.Com for all your electrical engineer projects? When you’re in the course of organising a major project, and the project requires electrical work, you should take into consideration hiring an electrical engineer. You may even want to examine calling in a pro when you have electrical problems that you’re trying to solve. Why should you be hiring a professional? Here are a couple of the perks you’ll have the ability to enjoy if you deal with an authority.

They’ll Help You To Avoid Key Errors – It’s not rare for anyone to make mistakes with regards to electrical work. Sadly, most of these mistakes can have harmful outcomes. You’ll want to use someone that’s aware about everything that might go wrong. When you employ someone with all the right expertise, they’ll have the ability to make certain that the task that you’re planning, gets completed without having a hitch.

They Can Provide Lots Of Useful Advice – You may not have much knowledge of electrical work. Thankfully, these experts have lots of knowledge that you just don’t. They’ll have the capacity to give feedback and advice that can be truly necessary to you. If you wind up utilizing someone similar to this, you’ll discover youself to be taking a lot of their comments on board.

They Can Help You To Complete A Project On Schedule – Lots of projects such as this wind up getting delayed, and these types of delays can be extremely costly. If it is something which you’d would rather prevent, a specialist will be able to ensure you won’t go off your schedule.

There are so many reasons to take into account hiring an electrical engineer. If you’re planning for a major project, and you think that you could potentially use an engineer, you need to start speaking with some professionals which can be in your general area. At NY Engineers, we have been able to help thousands of home renovation contractors who were searching for Electrical Engineers in or near Los Banos California with not only that but also services such as Engineering Reports Services. If you would like more info on the services we provide we ask that you consider on our blog.

Top Blog Article Related to Electrical Engineer Services in Los Banos California

Operating Modes of VRF Systems in HVAC Engineering

What Do Mechanical Engineers Do

Variable Refrigerant Flow (VRF) is an HVAC engineering (air conditioning) technology that achieves an extremely high efficiency by varying the flow of refrigerant to indoor units, based on the exact demand of each individual area. This ability to control the flow of refrigerant makes VRF systems ideal for applications with varying loads. In addition, VRF systems can also provide space heating, consolidating two building systems in one and saving space.

VRF technology is available in two versions – heat pump systems and heat recovery systems. Heat pump VRF systems can either cool or heat the entire building but cannot perform both functions at the same time. Heat recovery systems do not have this limitation and can serve simultaneous heating and cooling loads, thus leading to 3 different modes of operation:

  • Cooling mode
  • Heating mode
  • Simultaneous cooling & heating, or heat recovery mode

VRF Systems in Cooling Mode

In cooling mode, VRF operation is not very different from that of an air conditioning system: indoor units are supplied with liquid refrigerant, and an expansion valve inside each unit controls the amount of refrigerant flowing through. When refrigerant enters the cooling coil, it undergoes evaporation, removing heat from indoor air and thereby cooling the room. The heat extracted from indoor spaces is then rejected outdoors.

VRF systems are much more efficient than conventional packaged rooftop units (RTU), packaged terminal air conditioners (PTAC) and window units, according to HVAC engineering experts. Ductless mini-split systems and water-cooled chillers offer a similar efficiency in cooling mode but are unable to operate in heating mode.

VRF Systems in Heating Mode

Unlike cooling mode, where indoor units receive liquid refrigerant, here they are supplied with hot gas refrigerant. Gas flow to individual units is controlled with the same electronic expansion valves used for cooling mode, and the heating effect occurs when hot gas undergoes condensation.

The basic principle is still the refrigeration cycle, with the difference that heat is absorbed from outdoors and rejected indoors; in simple terms it is like air-conditioning the cooler outdoor environment to remove heat from it and use it indoors. This operating mode change is made possible with special 4-way reversing valves, which exchange the roles of evaporator and condenser between indoor and outdoor units.

In heating mode, the electric power consumed becomes useful heat, while in cooling mode it is rejected outdoors. Thus, a VRF outdoor unit can operate above 100% of its rated capacity when in heating mode. However, it is also important to note that the capacity may be derated, especially when the system is subject to a large variation in outdoor conditions. Longer piping lengths, longer distances between the outdoor unit and the last indoor unit, and higher vertical separation are some other causes of derating.

VRF Systems in Heat Recovery Mode

A heat recovery system is ideal when simultaneous heating and cooling are required. The greatest efficiency is achieved when the heating and cooling loads are equal, by maximizing the amount of energy transferred from one zone to another using the refrigerant. Heat rejection from cooling spaces can be utilized for space heating in the areas that need it at the same time. Thanks to this configuration, each occupant is free to choose either cooling or heating mode.

Heat recovery systems are very useful when a building has an east-west or south-north orientation with glass façades. East-west and south-north orientations cause a large difference in load requirements for each direction during the morning and evening, providing a chance for the VRF system to operate in simultaneous heating and cooling mode. Heat recovery is particularly useful in buildings with electrical rooms or data centers that need permanent cooling, since they also become a constant source of heat.

Heat Recovery System Piping Configurations in HVAC Engineering

Heat recovery systems come in 2-pipe and 3-pipe configurations, where the 2-pipe system is the option requiring the highest refrigerant flow. To operate with reduced flow, the 3-pipe system has a liquid line, a high-pressure gas line and a low-pressure gas line. The control function is achieved with a Mode Change Unit (MCU) or Mode Selection Box, which has three headers for high-pressure gas, low-pressure gas, and liquid.

  • When there are zones that need space heating, their indoor units work like condensers, supplying heat from the condensation of high-pressure refrigerant gas. After heating, the saturated refrigerant is fed to the liquid header.
  • Liquid refrigerant is then supplied to the units in space cooling mode, where it evaporates and absorbs heat, becoming a low-pressure gas.
  • The low-pressure gas is returned to its respective header and then to the compressor, repeating the cycle.

In this case, the outdoor unit must only provide the balance between heating and cooling – the one that is higher will determine the operating mode of the outdoor unit.

  • If cooling load is higher, the outdoor unit operates as a condenser, rejecting the surplus heat outdoors.
  • If the heating load is higher, the outdoor units operates as an evaporator, drawing from outdoor air the extra heat needed inside.

The best recommendation is locate the MCU in a public access area such as a corridor, thus minimizing noise and disruption for the end user. Maintenance of heat recovery systems is relatively easy, since the outdoor condenser unit is only connected to the MCU, facilitating system separation into upstream and downstream portions.

As per ASHRAE Standard 34-2013, the refrigerant concentration limit (RCL) is 26 lb per 1,000 ft3 of room volume for occupied spaces, and 13 lb per 1,000 ft3 for institutional buildings. This can be easily achieved by locating the units outside of compact rooms. According to Standard 15, a VRF system is classified as a direct system/high-probability system where a refrigerant leak can potentially enter occupied space.

The use of heat recovery systems in VRF proves to be better option, economically and environmentally, in these types of HVAC engineering systems. This spares the building owners from having to install and service two separate systems, while achieving a very high efficiency. With separate systems for space heating and cooling it is impossible to boost efficiency by exchanging heat, even if both systems are very efficient separately.

HVAC Engineer Career Path