Fire Protection Engineering Calumet City2018-11-20T20:11:54+00:00

Fire Sprinkler Design Engineer in Calumet City

Contact Us

If you’re looking for a competent Commercial & Residential Fire Sprinkler Systems Design near Calumet City Illinois? The one to go to is NY Engineers. Not only for Fire Sprinkler Systems Design Services but also Architectural Engineering and HVAC Firms in Chicago. Call us at 312 767.6877

Contact Us
MEP Engineering Firms

As of late when you ask any contracting company or developer anywhere from Irving Park to Loyola Chicago, about a reliable Electrical Engineering in Chicago, the most popular answer is reach out to NY-Engineers.Com. What is very well known is that New York Engineers is probably your top choice for anyone looking for a fire sprinkler system engineer in Calumet City. At NY-Engineers.Com our staff has many years of experience designing fire protection and sprinkler systems from Binghamton to Monsey, New York. Today, from our Chicago office we are helping contracting company and builders in Calumet City design the fire protection and sprinkler systems they need.

The danger of a building burnt down as a consequence of fire can be a sight that nobody wants to have. That is why fire protection engineers are hired before a building or apartment is made. Should you be wondering who needs fire protection engineer, then this first name that you should know is definitely the architect from the building. Exactly like an architect is vital to ensure the style of the building is perfect and protected from all ends; a fire protection engineer helps to ensure that the construction is protected from possible chances of fire.

Getting immediate reaction from your firefighting experts is alright but won’t it be better if a fire never occurred? You should think of “what if” rather than experiencing the horrifying experience of your building catching on fire. Fire protection engineers check out the style of the property first then chart the escape paths to be used in a fire. In addition to this, they are responsible for putting in many fire protection components in and outside the building. Water hoses and pipes attached to the main water supply, and checking the usefulness of the fire extinguishers are among the duties which the fire protection engineer carries out if they are hired.

Distinction Between Calumet City Fire Sprinkler Tech versus Protection Engineers

The Fire Protection Engineers Society features a explicit concept of Fire Protection Engineers vs Tech. Both positions need a solid education in fire technology and experience working as a firefighter typically.

The engineers use principles to utilize systems and methods setups in different structures that really help protect individuals and things from harm during fires. Engineers examine the location where the biggest fire threats lie and where to implement protection like sprinklers. They ensure that the use of structures and any materials inside them are designed to keep threats to a minimum.

Engineers will likely manage the connection and upkeep of smoke detectors, alarms systems, and may do investigations of fires after one occurs. This helps them avoid such things from happening down the road.

This sort of position needs scientific principles to aid enhance the safety of people in commercial and residential buildings. A fire technician works to do the testing and repair of the systems which were arranged and presented from the engineers.

They must also get the correct education and firefighting experience to work in the field. They may work to help install fire alarms and sprinkler systems but they will not arrange the layout of the systems like the engineers do. There is a great possibility you would like additional info about fire sprinkler design engineer services in Calumet City by New York Engineers you should visit at our Chicago Fire Protection Engineering blog.

MEP Engineering Related Blog Article

Mechanical Engineers Design HVAC Systems for Sensitive Environments

Architecture Engineering Salary

A well-designed HVAC system keeps temperature and moisture within a range that is considered comfortable for humans, while constantly renewing the air in a building and filtering out pollutants. Mechanical engineers are, in large part, responsible for ensuring that an HVAC system is operating as it should. The system must also provide an adequate airflow, since stagnant air and draftiness are both detrimental for performance.

In most residential and commercial settings, deviations from the ideal operating conditions are allowable if they are transitory, and there is generally a broad range of acceptable temperature and humidity values. However, there are sensitive environments such as healthcare facilities, where optimal conditions must be kept at all times. Many HVAC systems in less demanding environments are controlled based on temperature only, and humidity is controlled indirectly. However, sensitive environments require that each variable be monitored and controlled independently, and specialized high-performance filters may be required by codes.

Humidity Control in Sensitive Environments

Precise humidity control is typically required for environments with sensitive electronic equipment, healthcare facilities and other similar locations were human life or important systems are at stake. For example, the relative humidity levels for healthcare typically range from 40 to 60 percent:

  • Bacteria and viruses thrive with both low and high humidity levels.
  • Patients who suffer from asthma or allergic rhinitis also experience symptoms in response to humidity extremes.
  • Dry air absorbs moisture from mucous membranes, reducing the body’s ability to fight off infections.
  • Low humidity also increases static electricity accumulation, and discharges can damage modern medical equipment, which is important for medical procedures and generally expensive
  • Dust has a higher tendency to become airborne at low humidity levels, further increasing the chance of triggering allergic reactions.
  • High humidity creates the ideal conditions for mold and dust mites.

Depending on weather conditions, an HVAC system may be required to operate in humidification or drying mode at different times of the year. Some areas of a sensitive environment may have more stringent requirements than others; surgery rooms in hospitals are an example of this. It is the responsibility of qualified mechanical engineers to understand what is needed across various projects.

Air Dehumidification

There are two main approaches for controlling air humidity independently: the HVAC system can use cooling and heating coils in series, or a desiccant wheel can be deployed.

  • Cooling and heating coils: With this approach, air is cooled and dehumidified by the cooling coil until the desired relative humidity is reached. Since this normally results in overcooling, air then flows through a heating coil to raise its temperature back to an acceptable level. This way, both temperature and humidity requirements are met.
  • Desiccant wheel: This device captures air humidity downstream from the cooling coil, and releases it upstream for it to be condensed and gathered. At design conditions, this system does not require any heating input, although a preheating coil is added in case extra dehumidification is required.

Desiccant wheels typically save energy because they eliminate the need for overcooling and reheating. There may be exceptions, however, so it is important to assess each installation independently.

Air Humidification

Healthcare humidification systems are often based on steam, since heating water to high temperatures ensures the destruction of bacteria, especially Legionella. When steam is injected into an airstream, both humidification and heating are accomplished in the same step.

In the most sensitive environments, such as surgery rooms, steam-based humidification is normally required by law to ensure that the system is free from airborne bacteria. Adiabatic humidification is accepted in some sensitive applications, and it provides considerable savings compared with steam systems, although it is necessary to ensure it can be used legally.

Vapor Diffusion Retarders

Vapor diffusion retarders, also known as vapor barriers, complement air drying and humidification systems by providing a barrier against the diffusion of moisture through walls or other elements of the building envelope. Vapor diffusion retarders are classified into three main categories, depending on their rated permeance value:

  • Class I vapor barriers are rated for 0.1 perms or less. Some examples are glass, sheet metal and polyethylene.
  • Class II vapor barriers are rated for permeance values above 0.1 perms but less than or equal to 10 perms. Plywood and unfaced extruded polystyrene are two examples.
  • Class III vapor barriers have permeance values above 10 perms, and some examples are gypsum board, cellulose insulation, bricks and concrete blocks.

The specification of vapor barriers is strongly dependent on weather conditions, and can be especially challenging in northern states, due to how drastically temperature and relative humidity fluctuate throughout the year. Getting in touch with a qualified design firm is highly recommended.

Ventilation for Sensitive Environments: Air Changes per Hour and Filtering

Ventilation systems for sensitive environments must meet specific requirements in terms of air changes per hour (ACH). In surgery rooms, for example, the American Institute of Architects establishes 15 ACH, where 20% must be outdoor air.

  • In a surgery room with a floor area of 600 ft2 and a height of 10 ft, 15 ACH is equivalent to 90,000 ft3 per hour, or 1500 cfm. The outdoor air required would be 300 cfm to meet the 20% requirement.

Filters for sensitive applications must typically meet a minimum MERV rating, and in applications that are especially sensitive compliance with the HEPA standard may be required.

MERV Ratings

MERV stands for Minimum Efficiency Reporting Value, and it is a measurement scale for the effectiveness of filters, which was developed by ASHRAE in the 80s. The scale of MERV ratings ranges from 1 to 16, where larger numbers indicate that the filter is rated for smaller particles and has a higher average arrestance.

  • MERV 1-4: 60 to 80% arrestance, particles larger than 10.0 µm.
  • MERV 5-8: 80 to 95% arrestance, 3.0 to 10.0 µm.
  • MERV 9-12: 90 to 98% arrestance, 1.0 to 3.0 µm.
  • MERV 13-16: Over 95% arrestance, particles from 0.30 to 1.0 µm.

In healthcare applications, filters with MERV ratings of 7 or more are normally specified. In some applications, two filters in tandem are used, where the second has a higher MERV rating than the first.

HEPA Standard

HEPA stands for High-Efficiency Particulate Arrestance, and a filter must remove 99.97% of particles with a diameter of 0.3 µm to qualify as such. It is important to note that the term HEPA has been adopted to refer to any high-efficiency filter, but only those meeting the requirements set forth in the standard are real HEPA filters.

In healthcare applications, HEPA filters are widely used thanks to their ability to capture airborne bacteria and viruses. Once they have been trapped, high-power ultraviolet lights are used to kill them.

It is important to note that higher performance filters also involve an increased pressure drop, raising energy consumption. For this reason, it is important to select a filter with adequate performance for the application, but not over-specified.

General Recommendations from Mechanical Engineers for Sensitive Environment HVAC Design

The most important requirement for HVAC systems in sensitive environments is being able to control humidity and temperature simultaneously, while filtering out pollutants. Therefore, designs based on rules of thumb should be avoided:

  • Sizing air conditioning equipment in tons per square foot of floor area.
  • Sizing ventilation equipment in cfm per ton of HVAC capacity.

Instead, each system must be designed by mechanical engineers to meet a specific temperature and humidity range, as well as air changes per hour and percentage of outdoor air. Hiring the services of qualified engineering professionals is highly recommended to ensure that requirements are met.

Top searches related to Sprinkler Engineering in Calumet City