Fire Protection Engineering Dixmoor2018-11-03T20:31:32+00:00

Fire Sprinkler System Engineering in Dixmoor

Contact Us!

If you’re searching for a competent Fire Sprinkler Systems Design Services in Dixmoor Illinois? Your best bet is to call is NY-Engineers.Com. Not only for Fire Protection Contractor but also Mechanical Engineering and HVAC Firms in Chicago. Call us at (312) 767.6877

Contact Us!
Architectural Engineering Requirements

Today if you ask any contracting company or building owner form Fulton River District to Streeterville, about a professional MEP Engineering in Chicago, the most popular answer is reach out to NY Engineers. What’s very well known is that NY-Engineers.Com is more than likely your best bet for anyone looking for a fire sprinkler engineer in Dixmoor. At NY Engineers our team has many years of experience designing fire protection and sprinkler systems from Central Islip to West Hempstead, New York. Today, from our Chicago office we are helping contractor and developers in Dixmoor design the fire protection and sprinkler systems they need.

The possibility of a building burnt down because of fire is a sight that nobody wants to experience. That is the reason fire protection engineers are hired before a building or apartment is constructed. Should you be wondering who needs fire protection engineer, then a first name that you ought to know is the architect of your building. Exactly like an architect is vital to ensure the design of the property is perfect and safe from all ends; a fire protection engineer ensures that the property is safe from possible likelihood of fire.

Getting prompt response in the firefighting professionals is alright but won’t it be better if a fire never occurred? You have to consider “what if” instead of feeling the horrendous experience of the building being on fire. Fire protection engineers check out the design of the building first and then plan the escape paths to be used in a fire. Additionally, they are responsible for connecting several fire protection components in and outside the structure. Water hosepipes connected to the main water supply, and checking the fitness of the fire extinguishers are the duties that the fire protection engineer performs while they are hired.

Distinction Between Dixmoor Fire Sprinkler Tech versus Protection Engineers

The Society of Fire Protection Engineers has a specific concept of Fire Technology versus Protection Engineers. The two positions call for a solid education in fire technology and skill being a firefighter in many instances.

The engineers use principles to apply methods and systems setups in a variety of structures that really help protect individuals and things from harm during fires. Engineers examine the location where the biggest fire threats lie and the best places to put protection like sprinklers. They ensure that the usage of dwellings and any materials inside them are designed to keep risks as low as possible.

Engineers will likely manage the installation and upkeep of smoke detectors, alarms systems, and will do investigations of fires after it happens. This helps them prevent such things from occurring down the road.

This type of rank needs scientific principles to help improve the safety of individuals in commercial and residential buildings. A fire technician works to conduct the testing and upkeep of the systems which were arranged and laid out by the engineers.

They would also get the best education and firefighting experience to work within the field. They may also work to aid add sprinklers and fire alarm systems nevertheless they tend not to create the layout of those systems like the engineers do. There is a great possibility you would like additional information on fire sprinkler design engineer services in Dixmoor by New York Engineers you should take a look at our blog.

Sprinkler Engineering Related Post

Using Proper MEP Engineering to Protect Water Booster Pumps from Cavitation

Electrical Engineering Basics

Booster pumps play a very important role in ensuring a continuous water supply. In the absence of a booster system, most buildings only get a reliable water supply for the first five floors. For this same reason, keeping booster pumps under optimal operating conditions is a very important part of MEP engineering, and one of the main causes of impeller failure is an hydraulic phenomenon called cavitation. This article will provide an overview of cavitation and how it can be prevented.

What is Cavitation?

Everyone knows that water can be boiled with heat, turning it into vapor. However, low pressure can also vaporize water, and this can happen inside a pump if water is not supplied with enough pressure at the intake. When the pressure of a fluid drops below a critical value called the vapor pressure, small bubbles form in the flow, and these bubbles collapse violently once pressure increases again – the phenomenon is called cavitation, because the bubbles are cavities in the fluid.

You may be wondering how a pump reduces fluid pressure, when its actual purpose is to increase it. The answer can be explained with Bernoulli’s principle, which states that a fluid loses pressure as it speeds up or as it rises to a higher elevation. Water speeds up at the pump suction, and its pressure drops momentarily before being increased.

One bubble forming and collapsing does not cause major issues, but consider that thousands are continuously forming and imploding when a pump has severe cavitation issues. The combined shockwaves of all these bubbles gradually erode the pump impeller. When removed, the impeller blades will seem to have corroded, even though cavitation does not involve any chemical processes.

Other than impeller erosion, cavitation has many negative consequences in water booster pumps and other similar systems:

  • Vibration: The ongoing formation and collapse of bubbles not only wears down the impeller. The resulting shockwaves also shake the impeller, inducing vibrations in the entire shaft, with the potential to damage other system components. Seals and bearings are especially vulnerable to vibration.
  • Noise: Cavitation is very noisy due to the imploding bubbles. For a person close to the affected pump, it may sound like there are small rocks or marbles are being pumped along with water.
  • Decreased performance: Cavitation represents wasted energy, and this can be reflected as a reduction in flow or discharge pressure. A sudden drop in pump performance without an evident reason may indicate cavitation.

Preventing Cavitation With Adequate MEP Engineering

The technical specifications for pump manufacturers typically include a value called the Net Positive Suction Head (NPSH) required, which can be defined as simple terms as the minimum water head required at the pump suction for normal operation. If the actual head is above the NPSH required, no cavitation occurs.

In theory, cavitation can be prevented by increasing the suction pressure or by reducing the speed of water as it flows through the pump impeller. In practice, there are many ways to accomplish this effect.

  • Reduce pump speed: Cavitation is less likely at lower RPM values, so a booster pump can be slowed down with a variable frequency drive (VFD), as long as the system continues to meet the pressure and flow requirements in the local plumbing code.
  • Install the pump at a lower level: Static water pressure is higher at the lower levels of a building, so installing it at the lowest elevation possible reduces the chance of cavitation.
  • Reduce temperature: The critical pressure at which cavitation occurs increases as fluid temperature increases. If water must be pumped and heated, make sure the pump is installed upstream from the water heater.
  • Selecting the right pump: Many cavitation issues can be attributed to poor pump selection, and the issue disappears when a pump that matches the application is used.

The best solution for cavitation is not allowing it to occur in the first place, and this can be accomplished by working with qualified MEP engineering professionals from the start of a project. Modifying actual projects is far more expensive and time consuming than editing construction plans and specifications. A high-level professional design will not only prevent cavitation, but also optimal equipment capacity, energy efficiency and local code compliance.

Popular searches related to Sprinkler System Engineering in Dixmoor