Fire Protection Engineering North Park Chicago 2018-11-19T15:17:52+00:00

Fire Sprinkler Design Engineer in North Park Chicago

Contact Us!

If you’re searching for a dependable Fire Protection Engineer in North Park Chicago Illinois? The one to go to is NY-Engineers.Com. Not only for Fire Protection Engineer but also Construction Engineering and HVAC Chicago. Call us at 312 767.6877

Contact Us!
Electrical Engineering Information

As of late when you approach any contracting company or building owner form LeClaire Courts to South Edgebrook, about a professional Value Engineering in Chicago, the most popular answer is reach out to NY Engineers. What’s so well known is that NY Engineers is more than likely your best option for anyone looking for a fire sprinkler design engineer in North Park Chicago. At NY-Engineers.Com our crew has many years of experience designing fire protection and sprinkler systems from Syracuse to Smithtown, NY. Now, from our Chicago office we are helping contractor and developers in North Park Chicago design the fire protection and sprinkler systems they seek.

The possibility of a building burnt down due to fire is a sight that no one wants to experience. That is why fire protection engineers are hired before a building or apartment is constructed. Should you be wondering who needs fire protection engineer, then your first name you should know is definitely the architect of the building. Just like an architect is essential to ensure the design of your building is perfect and resistant to all ends; a fire protection engineer makes certain that the construction remains safe and secure from possible odds of fire.

Seeing prompt response from the firefighting professionals is okay but wouldn’t it be better if a fire never took place? You need to consider “what if” rather than going through the horrendous scene of your building catching on fire. Fire protection engineers browse through the model of the property first and after that chart the escape routes to be taken during a fire. Additionally, they are responsible for connecting many fire protection things in and out of the structure. Water hoses and pipes linked to the main water supply, and checking the condition of the fire extinguishers are some of the duties the fire protection engineer carries out while they are hired.

Distinction Between North Park Chicago Fire Protection Engineers vs Tech

The Society of Fire Protection Engineers includes a specific concise explanation of Fire Technology versus Protection Engineers. Both positions require a solid education in fire technology and experience as being a firefighter in most cases.

The engineers use principles to make use of methods and systems setups in several buildings that really help protect folks and things from injury during fires. Engineers examine the location where the biggest fire threats lie and where to install protection such as sprinklers. They ensure that the utilization of buildings and any materials in them are designed to keep threats to a minimum.

Engineers will likely supervise the installation and upkeep of alarm systems, smoke detectors, and may do investigations of fires after one occurs. It will help them avoid such things from happening down the road.

This particular position needs scientific principles to aid boost the safety of individuals in commercial buildings. A fire technician functions is to do the testing and upkeep of the systems that were arranged and laid out with the engineers.

These individuals must also get the correct schooling and firefighting knowledge to be effective in the field. They can also work to help add sprinklers and fire alarm systems nevertheless they tend not to plan the layout of these systems like the engineers do. Even with all of this information you would like more details about fire sprinkler engineer services in North Park Chicago by NY-Engineers.Com we invite you to stop by at our blog.

New Energy Modeling Related Post

Ask an Electrical Engineering Professional: Are My Electric Motors Well Protected?

HVAC Engineer Career Path

Electric motors are normally out of sight, but they perform many important functions in residential, commercial and industrial buildings. Electric motors are used to drive air handlers, chillers, furnace blowers, water pumps and elevators, to name a few examples. For this reason, it is an important part of electrical engineering to keep them in optimal operating condition, and an important aspect of safe motor operation is providing them with reliable electrical protections.

Three-phase electric motors are normally used for mid- or large-sized equipment, and they are characterized by operating with three live conductors. These motors require specialized protections due to their connection. In smaller applications, such as fractional horsepower fans, single-phase electric motors are normally used.

These use either two live conductors, or a live conductor and a neutral conductor.

Motor faults are almost always disruptive because key equipment is taken out of operation. Also consider that electric motors are expensive, so it is in the best interest of property management companies to avoid replacements. In a few words, adequate motor protection pays off in the long run.

This article will provide an overview of the main electrical issues that threaten motors, and how to provide protection against them. If you are planning a major building renovation, it represents a good opportunity to upgrade motor equipment and improve electrical protection.

Protection Against Major Electrical Faults With Proper Electrical Engineering

Some faults cause the electrical current of a motor to increase drastically to many times its normal value. These faults must be disconnected immediately, or they cause irreversible damage to the motor, while being capable of starting a fire.  The electrical current can reach extremely high values under the following circumstances:

  • Contact between a live conductor and a neutral conductor.
  • Contact between a live conductor and a grounded surface or conductor.
  • Contact between two or more live conductors.

These faults cause what is called a short circuit in electrical engineering: a low-resistance connection between two points at different voltage values, which causes an extremely high current – often with magnitude in the thousands of amperes.

Motor protections use a magnetic tripping mechanism to clear these dangerous faults. The short circuit current induces a strong magnetic field through an electromagnet, which in turn forces a contact to open, disconnecting the motor from its power supply.

Electric motors draw a high inrush current when they start, which can reach values up to 800% of the motor’s rated current. This is normal behaviour and it only lasts for brief moments while the motor starts rotating, so it does not count as a fault. Motor protections must be sized to allow the inrush current, while clearing anything higher.

Protection Against Motor Overload

An overload is a less drastic type of fault where the motor is drawing current above its rated value, but only by a slight margin. However, overloads cause electric motors to heat up excessively, which shortens their service life.

Unlike short circuit protection, which is instantaneous, overload protection has a built-in time delay. This allows short-duration currents above the rated value that are normal in some types of equipment, such as the inrush current when a motor starts. In fact, if the motor fails to start for any reason, such as an obstacle locking the shaft or excessive load, the overload protection activates and disconnects the motor.

Overload protection acts faster as the current magnitude increases, which means a current slightly above the rated value may take minutes to be cleared, while a drastic overcurrent may be cleared in seconds. Currents that are high enough to activate the short-circuit protection described in the previous section cause immediate disconnection.

Overload protection can be either thermal or electronic. When it is thermal, it is based on a contact that expands with heat: more current causes more heat, and more heat causes a quicker disconnection. On the other hand, electronic overload protection uses a programmed response with the same behavior as the thermal protection, and the current is measured to determine how fast the contact will open.

Protection Against Voltage Changes

Motors have a rated voltage value, but they normally tolerate a variation of 10% above and below this value. However, the operating voltage should be as close as possible to the rated value to ensure optimal performance. When the voltage supplied to a motor is too low or too high, it draws a higher current, which overheats its windings and shortens its service life.

There are special overvoltage and undervoltage relays that measure the voltage being supplied to the motor and disconnect the power supply if the voltage falls outside the acceptable range. These relays are often adjustable, so it is important to establish a reasonable voltage range:

  • A range that is too narrow above and below the rated voltage may result in unwanted motor disconnections, since even minor voltage variations result in disconnection.
  • However, a range that is too broad does not provide adequate protection because the voltage is allowed to change drastically.

Protection Against Phase Loss and Phase Imbalance

Single-phase motors shut down when one of their conductors is disconnected, even if the other remains, since there is no path for electric current. On the other hand, three-phase motors can continue operating with only two-phase conductors, but this is extremely demanding for the motor and shortens its service life. Keep in mind that interrupting the voltage to any phase conductor has the same effect as disconnecting the conductor – the motor is left with a voltage supply in only two of its three terminals.

A related issue is phase imbalance, which occurs when the voltage supplied to a three-phase motor varies drastically between phases. Phase imbalance causes the motor to produce more noise and heat, while decreasing its efficiency and service life. Ideally, phase imbalance should be kept below 2% for optimal motor performance.

Phase monitors are devices that track the phase voltages of a motor and can be integrated with a contactor to disconnect the motor in the event of excessive imbalance or phase loss.

Conclusion

Adequate motor protection can be considered an investment in electrical engineering, since it prevents damage to expensive equipment. It also makes building interiors safer, since electrical faults with the potential to start a fire are cleared before they have a chance to do so. By working with qualified electrical design engineers, you can make sure all your electrical motors are specified with reliable protections and installed according to the codes relevant to your area.

Top searches related to Sprinkler Engineering in North Park Chicago