When you re looking for a fast responding Commercial & Residential Fire Sprinkler Systems Design near Princeton Park Chicago Illinois? Your best bet is to reach out to is NY Engineers. Not only for Fire Sprinkler Plumbing Design Experts but also Electrical Engineering and HVAC Firms in Chicago. Call (+1) (312) 767-6877

Contact Us!
Electrical Engineering Information

Nowadays when you solicit any contracting company or building owner anywhere from Central Station Chicago to Palmer Square, about a affordable Value Engineering in Chicago, the most popular answer is reach out to NY Engineers. What’s very well known is that NY Engineers is more than likely your best option for anyone looking for a fire protection engineering in Princeton Park Chicago. At New York Engineers our staff has many years of experience designing fire protection and sprinkler systems from Mount Vernon to Rockville Centre, NY. Today, from our Chicago office we are helping general contractor and builders in Princeton Park Chicago design the fire protection and sprinkler systems they need.

The danger of a building burnt down because of fire can be a sight that nobody wants to discover. That is the reason fire protection engineers are hired before a building or apartment is built. If you are wondering who needs fire protection engineer, then a first name that you should know is definitely the architect in the building. The same as an architect is essential to make sure that the style of the construction is ideal and resistant to all ends; a fire protection engineer makes certain that the property remains safe and secure from possible likelihood of fire.

Having prompt response from your firefighting experts is acceptable but won’t it be great if a fire never occurred? You must imagine “what if” as an alternative to feeling the horrifying experience of your building catching on fire. Fire protection engineers go through the design of the construction first and after that plan the escape routes to be used in a fire. Additionally, they are responsible for putting in many fire protection items inside and outside the building. Water hoses and pipes attached to the main water tank, and checking the usefulness of the fire extinguishers are among the duties which the fire protection engineer carries out if they are hired.

Distinction Between Princeton Park Chicago Fire Sprinkler Tech versus Protection Engineers

The Society of Fire Protection Engineers includes a specific concise explanation of Fire Protection Engineers vs Tech. The two positions require a solid education in fire technology and practive as a firefighter typically.

The engineers use principles to use systems and methods setups in a variety of structures that can help protect individuals and animals from injury during fires. Engineers study the location where the biggest fire threats lie and where you should put protection such as sprinklers. They make certain that the use of dwellings as well as any materials in them are meant to keep hazards as low as possible.

Engineers may also supervise the fitting and maintenance of alarm systems, smoke detectors, and will do investigations of fires after it happens. It will help them prevent such incidences from happening in the foreseeable future.

This particular position uses scientific principles to aid enhance the safety of individuals in commercial buildings. A fire technician works to do the testing and upkeep of the systems which have been arranged and presented from the engineers.

These folks also needs to possess the correct education and firefighting training to be effective within the field. They might also work to help add fire alarms and sprinkler systems nevertheless they usually do not plan the layout of these systems just like the engineers do. There is a great possibility you would like additional information about fire sprinkler system engineer services in Princeton Park Chicago by NY Engineers you should check out at our blog.

Latest Value Engineering Related Blog

Using Proper MEP Engineering to Protect Water Booster Pumps from Cavitation

Is There A Demand For Mechanical Engineers In The Future

Booster pumps play a very important role in ensuring a continuous water supply. In the absence of a booster system, most buildings only get a reliable water supply for the first five floors. For this same reason, keeping booster pumps under optimal operating conditions is a very important part of MEP engineering, and one of the main causes of impeller failure is an hydraulic phenomenon called cavitation. This article will provide an overview of cavitation and how it can be prevented.

What is Cavitation?

Everyone knows that water can be boiled with heat, turning it into vapor. However, low pressure can also vaporize water, and this can happen inside a pump if water is not supplied with enough pressure at the intake. When the pressure of a fluid drops below a critical value called the vapor pressure, small bubbles form in the flow, and these bubbles collapse violently once pressure increases again – the phenomenon is called cavitation, because the bubbles are cavities in the fluid.

You may be wondering how a pump reduces fluid pressure, when its actual purpose is to increase it. The answer can be explained with Bernoulli’s principle, which states that a fluid loses pressure as it speeds up or as it rises to a higher elevation. Water speeds up at the pump suction, and its pressure drops momentarily before being increased.

One bubble forming and collapsing does not cause major issues, but consider that thousands are continuously forming and imploding when a pump has severe cavitation issues. The combined shockwaves of all these bubbles gradually erode the pump impeller. When removed, the impeller blades will seem to have corroded, even though cavitation does not involve any chemical processes.

Other than impeller erosion, cavitation has many negative consequences in water booster pumps and other similar systems:

  • Vibration: The ongoing formation and collapse of bubbles not only wears down the impeller. The resulting shockwaves also shake the impeller, inducing vibrations in the entire shaft, with the potential to damage other system components. Seals and bearings are especially vulnerable to vibration.
  • Noise: Cavitation is very noisy due to the imploding bubbles. For a person close to the affected pump, it may sound like there are small rocks or marbles are being pumped along with water.
  • Decreased performance: Cavitation represents wasted energy, and this can be reflected as a reduction in flow or discharge pressure. A sudden drop in pump performance without an evident reason may indicate cavitation.

Preventing Cavitation With Adequate MEP Engineering

The technical specifications for pump manufacturers typically include a value called the Net Positive Suction Head (NPSH) required, which can be defined as simple terms as the minimum water head required at the pump suction for normal operation. If the actual head is above the NPSH required, no cavitation occurs.

In theory, cavitation can be prevented by increasing the suction pressure or by reducing the speed of water as it flows through the pump impeller. In practice, there are many ways to accomplish this effect.

  • Reduce pump speed: Cavitation is less likely at lower RPM values, so a booster pump can be slowed down with a variable frequency drive (VFD), as long as the system continues to meet the pressure and flow requirements in the local plumbing code.
  • Install the pump at a lower level: Static water pressure is higher at the lower levels of a building, so installing it at the lowest elevation possible reduces the chance of cavitation.
  • Reduce temperature: The critical pressure at which cavitation occurs increases as fluid temperature increases. If water must be pumped and heated, make sure the pump is installed upstream from the water heater.
  • Selecting the right pump: Many cavitation issues can be attributed to poor pump selection, and the issue disappears when a pump that matches the application is used.

The best solution for cavitation is not allowing it to occur in the first place, and this can be accomplished by working with qualified MEP engineering professionals from the start of a project. Modifying actual projects is far more expensive and time consuming than editing construction plans and specifications. A high-level professional design will not only prevent cavitation, but also optimal equipment capacity, energy efficiency and local code compliance.