Do not be misled by our NY-Engineers.Com is your best option if you need a Full Service Heating Cooling Air Conditioning Furnace (HVAC) Engineering Firm in Chicago Illinois. We’re not only an HVAC Chicago but also a leading provider of Sprinkler Engineering services in Bellwood. Call (+1) 312 767.6877

Contact Us!

As of late Many people have been taking a look at the NY Engineers site in search of HVAC Engineering in the Chicago area. This is due primarily due to the following we have built in this kind of work. With that said, a lot of general contractors from McCook to Skokie, do not know that NY Engineers is also a top choice for anyone searching for HVAC Chicago, Illinois

The quest for power efficient buildings involves power efficient HVAC system design. This will likely include systems for domestic water heating, architectural enclosure, HVAC, lighting, and vertical transportation. The loads for that HVAC systems will come primarily from five different sources including lighting (cooling), the building envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load might be a purpose of either the instruments needed in an attempt to introduce it in a space and control contaminant concentration or the quantity of individuals that may be in the area. In the majority of climates within the southwestern and eastern parts of the united states, to lessen outside ventilation helps you to save energy whenever the surface air is either humid and warm or very cold.
Managing the ventilation rate is going to be dependant on occupancy which is called a type of demand control ventilation. This can be a common type of energy conservation strategy that is utilized for spaces with occasional or crowded occupancy. Having heating and cooling loads dropped as low as possible can be carried out by making use of an increased performance building envelope, occupancy sensors, and high performance lighting that employs daylight response of lighting controls.

Chicago HVAC Engineering services vs HVAC Technicians

If you’ve ever considered the difference between a HVAC Technician vs HVAC Engineers, then continue reading:

Chicago HVAC engineers would be the folks that manage the installation of air cooling systems for residential and commercial buildings. They spend a lot of their day in offices doing more impressive range management and planning of installations but they do also see job sites every once in awhile.

In comparison, HVAC technicians usually do a lot of the hands-on work  that deals with repair and maintenance. A HVAC tech may work with or for an engineer to do a number of the installation task, specifically for smaller jobs. On the whole HVAC techs do a lot more travel and may spend time and effort identifying leaks, changing filters, doing recharges or getting rid of old and outdated systems that use old refrigerants.

HVAC engineers could possibly have the chance to make more decisions about systems that are used, and so they are the people who would offer advice about probably the most sensible refrigerants and which systems would best suit a bigger building. In the industry, there exists some challenge between ‘the suits’ and ‘the ones that get their hands dirty’, but both jobs require an excellent understanding of how air conditioner works. Nowadays many individuals have been reading our sites searching for HVAC Certification Chicago. Nevertheless, the focus of our organization is to become the to go to company for those searching for a HVAC Firm in or near Chicago and or any of our other services including Sprinkler Engineering services. We ask that anybody searching for additional details about our Heating Cooling Air Conditioning Furnace (HVAC) Engineering Firm in Chicago Illinois takes a look at our blog.

New Blog Related to HVAC Contractor in Chicago

Architectural Engineers Detail Ventilation System Configurations

MEP Engineering Books

Human activity generates a broad range of compounds that become dangerous in high-enough concentrations, and pollutants from outdoor sources can also degrade indoor air quality. Architectural engineers are often charged with the job of preventing this from occurring as much as possible.

Ventilation systems keep these substances at low levels by constantly renewing indoor air, and they also contribute to keeping moisture within the range of 30 to 60 percent as recommended by ASHRAE. Without ventilation, it would not be possible to keep indoor environments comfortable and healthy.

Natural ventilation relies on wind currents, outdoor temperature and other weather conditions to supply fresh air. The advantage of natural ventilation is that it comes for free, and in new buildings it is possible to optimize architectural design to maximize its effects. However, natural ventilation is uncontrollable, and generally insufficient to fully meet the requirements of modern buildings.

Normally, to meet ASHRAE standards and local building codes, mechanical ventilation must be deployed. Depending on their configuration, whole-house ventilation systems can be classified into three main types:

  • Exhaust ventilation systems, which only use extractor fans.
  • Supply ventilation systems, which only use injector fans.
  • Balanced ventilation systems, which use both injector and extractor fans.

Balanced systems can be enhanced with energy-recovery ventilation, a technology that exchanges energy between the supply and exhaust airflows to maximize performance and minimize the overall running cost of the system.

Exhaust Ventilation Systems

As implied by their name, exhaust ventilation systems only deploy extractor fans. When the system starts to run, it creates a negative pressurization effect in occupied spaces, drawing in fresh outdoor air to renew that which is exhausted. It is important to note, however, that exhaust ventilation is not possible in air-tight buildings, since outdoor air must be allowed to leak in. If the building envelope has been tightened with caulking and weather stripping, exhaust ventilation must be complemented with intake vents.

Exhaust ventilation systems have a single set of fans and ducts, which makes them affordable while reducing their installation time and cost. Energy expenses are relatively low because there is only one set of fans in operation, and maintenance is simplified as well. The system layout can be designed to target specific areas where pollutants are generated, ensuring they are removed before they spread indoors.

Exhaust ventilation generally achieves the best results in cold and dry climates, where outdoor air does not require dehumidification. It is not recommended for tropical and mixed climates, because warm and humid outdoor air is drawn in without control, driving up cooling and dehumidification expenses. Also, keep in mind that depressurization draws air from all surrounding spaces, with little control over pollutant content. In general, architectural engineers recommend exhaust ventilation for cold weather, and when outdoor air pollution is low.

Another risk of exhaust ventilation is backdraft, which occurs when a combustion-based appliance suddenly draws in a lot of air, potentially causing a flashover. Since exhaust ventilation causes negative pressurization and does not control air supply, there is an increased chance of backdraft.

Supply Ventilation Systems

Supply ventilation only uses injector fans, pressurizing rooms and causing indoor air to leak out constantly. The main advantage of supply ventilation is control, since outdoor air can be filtered, humidified or dried as needed. In addition, the pressurization effect prevents the inflow of pollutants from surrounding spaces or from outdoors.

Another benefit of supply ventilation is that it eliminates the risk of backdraft from combustion appliances due to positive pressurization. Installation, operation and maintenance expenses are also reduced thanks to the simple system configuration.

Supply ventilation is better suited for tropical or mixed climate conditions, where dehumidification and filtering are often required. This configuration tends to cause trouble in cold weather, since the pressurization effect can cause condensation of indoor air humidity, leading to moisture accumulation and its common side-effects: furniture damage and the proliferation of mold, bacteria and dust mites.

Balanced Ventilation Systems

A balanced ventilation system is the result of combining exhaust and supply ventilation: both airflows can be controlled, providing the benefits of both system configurations. Of course, this comes at a higher installation and operation cost, since there are now two sets of fans and ducts.

Balanced ventilation is suitable for all weather conditions, and airflows can be adjusted to provide any pressurization effect as required – positive, negative or neutral. The recommended locations for each set of ducts are the following:

  • Supply ducts should focus on areas where occupants spend most of their time, including living rooms and bedrooms. This ensures that these areas always have a supply of fresh and clean air.
  • Exhaust ducts should focus on areas where moisture and humidity are released frequently, such as kitchens, bathrooms, laundries and boiler rooms.

Of course, it is possible to install supply and exhaust rooms for every room, but system costs are increased significantly. With the approach presented above, system costs are optimized without compromising performance.

Energy-Recovery Ventilation: Architectural Engineers Improve the
Efficiency of Balanced Ventilation

Energy-recovery ventilation consists on exchanging energy between the supply and exhaust air, so that overall HVAC costs are minimized. These systems can be classified into two main types:

  • Heat-Recovery Ventilation (HRV)systems only exchange heat between the supply and exhaust airflows.
  • Enthalpy-Recovery Ventilation (ERV)systems exchange both heat and moisture.

Summer Operation

In the summer, outdoor air typically requires cooling and dehumidification. However, when air is exhausted, it is still cooler and drier than the supply air; therefore, a part of the energy used for cooling and dehumidification is lost.

  • The use of a heat exchanger (HRV) can improve energy efficiency: the exhaust air is used to precool the supply air without mixing both airstreams.
  • If an ERV system is used, moisture is also transferred from the supply air to the exhaust air, further improving air-conditioning efficiency because there is less moisture to remove.

Winter Operation

During the winter, HVAC needs are reversed because outdoor air typically requires heating and humidification. The operating principle of HRV and ERV is the same, but the direction in which heat and humidity are transferred is inverted.

  • The exhaust air is warmer, and the heat exchanger captures a part of that thermal energy to preheat the supply air.
  • If ERV is used, moisture is also retrieved from the exhaust air and provided to the supply air.

General Recommendations for HRV and ERV

It is important to note that HRV and ERV systems are significantly more complex than the ventilation systems presented before. They can only be installed and serviced by qualified personnel, which increases their cost of ownership. Compared with a basic balanced ventilation system, HRV and ERV systems have a higher running cost, but overall HVAC expenses are reduced.

HRV and ERV systems increase in effectiveness where temperature  and moisture extremes are reached during the summer or winter, or when heating fuel costs are high. Their benefits are diminished under moderate weather conditions, where the added running cost may be higher than the savings achieved – balanced ventilation is a better alternative in these cases.

Spot Ventilation: A Complement for Whole-House Ventilation

Spot ventilation consists on using exhaust fans to extract pollutants and humidity at the room where they are released, preventing them from being spread throughout other indoor spaces. In residential settings, spot ventilation is most commonly used in bathrooms and kitchens to meet the minimum exhaust air levels established in both the area mechanical codes and ASHRAE standards:

  • Bathrooms require 50 cfm of intermittent ventilation or 20 cfm of continuous ventilation.
  • Kitchens require 100 cfm or intermittent ventilation or 25 cfm of continuous ventilation.

Spot ventilation can be a great complement for supply ventilation systems, removing pollutants from key areas. This combination provides many of the benefits of a balanced ventilation system without having to install a full set of exhaust fans and ducts. According to experienced architectural engineers, the only disadvantage of this combination is that HRV and ERV systems are unfeasible, since there is no point where heat or moisture can be exchanged between airflows.