HVAC Carpentersville2018-11-20T13:59:41+00:00

HVAC Carpentersville | Expert Energy Efficient System Designs

Value Engineering
Contact Us

Do not be fooled by the name NY Engineers is the top choice if you are searching for Full Service Air Conditioning, Heating & Cooling (HVAC) Engineering Firm in Chicago Illinois. We are not only an HVAC Chicago but also a leading provider of Protection Engineering services throughout Carpentersville. Call us at 312 767.6877

Contact Us

Recently huge crowds have been taking a look at the NY-Engineers.Com site looking for Value Engineering near Chicago. This is due primarily due to the following we have built in this kind of work. Nevertheless, a lot of general contractors from Glencoe to Munster, don’t know that NY Engineers is also the ideal choice for anyone searching for HVAC Chicago, Illinois.

The pursuit of energy efficient buildings involves energy-efficient HVAC system design. This can include systems for lighting, architectural enclosure, domestic water heating, HVAC, and vertical transportation. The loads for that HVAC systems will come primarily from five different bases including lighting (cooling), your building envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load might be a function of either the mechanisms necessary to be able to introduce it in to a space and control contaminant concentration or the quantity of folks that may use the room. In virtually all climates in the southwestern and eastern parts of america, to minimize outside air-flow can save energy whenever the exterior air is either humid and warm or very cold.
Controlling the ventilation rate is going to be dependant upon occupancy which is called a variety of demand control ventilation. This can be a common type of energy conservation strategy that is utilized for homes with intermittent or dense occupancy. Having heating and cooling loads dropped as low as possible can be achieved by making use of a high performance building envelope, occupancy sensors, and high performance lighting that utilize daylight response of lighting controls.

Chicago HVAC Engineers vs HVAC Technicians

When you have ever considered the distinction between a HVAC Technician vs HVAC Engineers, then read on:

HVAC engineers are definitely the individuals who supervise the installation of air conditioner systems for residential and commercial buildings. They spend a great deal of their time in offices doing advanced level organization and arranging of installations nonetheless they do also stop by job sites every now and then.

In comparison, HVAC technicians usually do a lot of the hands-on work with maintenance and repair. A HVAC tech may work with or for an engineer to perform a number of the installation work, particularly for smaller jobs. Generally speaking HVAC technicians do much more travel and may spend considerable time changing filters, identifying leaks, doing recharges or decommissioning old and outdated systems which use old refrigerants.

HVAC engineers could have the ability to make more decisions about systems that are employed, plus they are definitely the folks that would offer advice about one of the most sensible refrigerants and which systems would work best with a larger building. In the trade, there is some rivalry between ‘the suits’ and ‘the ones which get their hands dirty’, but both jobs do require an excellent familiarity with how air-con works. In recent times huge crowds have been visiting our website looking for things like Four Seasons HVAC Chicago Reviews. Nevertheless, the focus of our company is to be the top option for anyone seeking a HVAC Chicago and or any of our other services including Electrical Engineering Engineering services. Furthermore everybody searching for more details about our Air Conditioning, Heating & Cooling (HVAC) Engineering Firm in Chicago Illinois stops by at our blog!

New Article Related to HVAC Firm near Chicago

Mechanical Engineers Design HVAC Systems for Sensitive Environments

Value Engineering Pdf

A well-designed HVAC system keeps temperature and moisture within a range that is considered comfortable for humans, while constantly renewing the air in a building and filtering out pollutants. Mechanical engineers are, in large part, responsible for ensuring that an HVAC system is operating as it should. The system must also provide an adequate airflow, since stagnant air and draftiness are both detrimental for performance.

In most residential and commercial settings, deviations from the ideal operating conditions are allowable if they are transitory, and there is generally a broad range of acceptable temperature and humidity values. However, there are sensitive environments such as healthcare facilities, where optimal conditions must be kept at all times. Many HVAC systems in less demanding environments are controlled based on temperature only, and humidity is controlled indirectly. However, sensitive environments require that each variable be monitored and controlled independently, and specialized high-performance filters may be required by codes.

Humidity Control in Sensitive Environments

Precise humidity control is typically required for environments with sensitive electronic equipment, healthcare facilities and other similar locations were human life or important systems are at stake. For example, the relative humidity levels for healthcare typically range from 40 to 60 percent:

  • Bacteria and viruses thrive with both low and high humidity levels.
  • Patients who suffer from asthma or allergic rhinitis also experience symptoms in response to humidity extremes.
  • Dry air absorbs moisture from mucous membranes, reducing the body’s ability to fight off infections.
  • Low humidity also increases static electricity accumulation, and discharges can damage modern medical equipment, which is important for medical procedures and generally expensive
  • Dust has a higher tendency to become airborne at low humidity levels, further increasing the chance of triggering allergic reactions.
  • High humidity creates the ideal conditions for mold and dust mites.

Depending on weather conditions, an HVAC system may be required to operate in humidification or drying mode at different times of the year. Some areas of a sensitive environment may have more stringent requirements than others; surgery rooms in hospitals are an example of this. It is the responsibility of qualified mechanical engineers to understand what is needed across various projects.

Air Dehumidification

There are two main approaches for controlling air humidity independently: the HVAC system can use cooling and heating coils in series, or a desiccant wheel can be deployed.

  • Cooling and heating coils: With this approach, air is cooled and dehumidified by the cooling coil until the desired relative humidity is reached. Since this normally results in overcooling, air then flows through a heating coil to raise its temperature back to an acceptable level. This way, both temperature and humidity requirements are met.
  • Desiccant wheel: This device captures air humidity downstream from the cooling coil, and releases it upstream for it to be condensed and gathered. At design conditions, this system does not require any heating input, although a preheating coil is added in case extra dehumidification is required.

Desiccant wheels typically save energy because they eliminate the need for overcooling and reheating. There may be exceptions, however, so it is important to assess each installation independently.

Air Humidification

Healthcare humidification systems are often based on steam, since heating water to high temperatures ensures the destruction of bacteria, especially Legionella. When steam is injected into an airstream, both humidification and heating are accomplished in the same step.

In the most sensitive environments, such as surgery rooms, steam-based humidification is normally required by law to ensure that the system is free from airborne bacteria. Adiabatic humidification is accepted in some sensitive applications, and it provides considerable savings compared with steam systems, although it is necessary to ensure it can be used legally.

Vapor Diffusion Retarders

Vapor diffusion retarders, also known as vapor barriers, complement air drying and humidification systems by providing a barrier against the diffusion of moisture through walls or other elements of the building envelope. Vapor diffusion retarders are classified into three main categories, depending on their rated permeance value:

  • Class I vapor barriers are rated for 0.1 perms or less. Some examples are glass, sheet metal and polyethylene.
  • Class II vapor barriers are rated for permeance values above 0.1 perms but less than or equal to 10 perms. Plywood and unfaced extruded polystyrene are two examples.
  • Class III vapor barriers have permeance values above 10 perms, and some examples are gypsum board, cellulose insulation, bricks and concrete blocks.

The specification of vapor barriers is strongly dependent on weather conditions, and can be especially challenging in northern states, due to how drastically temperature and relative humidity fluctuate throughout the year. Getting in touch with a qualified design firm is highly recommended.

Ventilation for Sensitive Environments: Air Changes per Hour and Filtering

Ventilation systems for sensitive environments must meet specific requirements in terms of air changes per hour (ACH). In surgery rooms, for example, the American Institute of Architects establishes 15 ACH, where 20% must be outdoor air.

  • In a surgery room with a floor area of 600 ft2 and a height of 10 ft, 15 ACH is equivalent to 90,000 ft3 per hour, or 1500 cfm. The outdoor air required would be 300 cfm to meet the 20% requirement.

Filters for sensitive applications must typically meet a minimum MERV rating, and in applications that are especially sensitive compliance with the HEPA standard may be required.

MERV Ratings

MERV stands for Minimum Efficiency Reporting Value, and it is a measurement scale for the effectiveness of filters, which was developed by ASHRAE in the 80s. The scale of MERV ratings ranges from 1 to 16, where larger numbers indicate that the filter is rated for smaller particles and has a higher average arrestance.

  • MERV 1-4: 60 to 80% arrestance, particles larger than 10.0 µm.
  • MERV 5-8: 80 to 95% arrestance, 3.0 to 10.0 µm.
  • MERV 9-12: 90 to 98% arrestance, 1.0 to 3.0 µm.
  • MERV 13-16: Over 95% arrestance, particles from 0.30 to 1.0 µm.

In healthcare applications, filters with MERV ratings of 7 or more are normally specified. In some applications, two filters in tandem are used, where the second has a higher MERV rating than the first.

HEPA Standard

HEPA stands for High-Efficiency Particulate Arrestance, and a filter must remove 99.97% of particles with a diameter of 0.3 µm to qualify as such. It is important to note that the term HEPA has been adopted to refer to any high-efficiency filter, but only those meeting the requirements set forth in the standard are real HEPA filters.

In healthcare applications, HEPA filters are widely used thanks to their ability to capture airborne bacteria and viruses. Once they have been trapped, high-power ultraviolet lights are used to kill them.

It is important to note that higher performance filters also involve an increased pressure drop, raising energy consumption. For this reason, it is important to select a filter with adequate performance for the application, but not over-specified.

General Recommendations from Mechanical Engineers for Sensitive Environment HVAC Design

The most important requirement for HVAC systems in sensitive environments is being able to control humidity and temperature simultaneously, while filtering out pollutants. Therefore, designs based on rules of thumb should be avoided:

  • Sizing air conditioning equipment in tons per square foot of floor area.
  • Sizing ventilation equipment in cfm per ton of HVAC capacity.

Instead, each system must be designed by mechanical engineers to meet a specific temperature and humidity range, as well as air changes per hour and percentage of outdoor air. Hiring the services of qualified engineering professionals is highly recommended to ensure that requirements are met.

Top Ssearch Queries Related to HVAC Chicago