HVAC Cragin Chicago2018-11-24T11:32:16+00:00

HVAC Cragin Chicago | Expert Energy Efficient System Designs

Value Engineering Architecture
Contact Us!

Don’t be fooled by the name NY-Engineers.Com is your best option if you are searching for Full Service Heating & Air Conditioning (HVAC) Engineering Firm in Chicago Illinois. We’re not only an HVAC Contractor in or near Chicago but also a leading provider of Sprinkler System Engineering services in Cragin Chicago. Call us at (+1) 312 767-6877

Contact Us!

As of late huge crowds have been visiting the NY Engineers site searching for Electrical Engineering in Chicago. This is due primarily due to the following we have built in this kind of work. With that said, many building owners from Countryside to Whiting, IL, don’t know that NY-Engineers.Com is also the ideal choice for anyone searching for HVAC Chicago, IL!

The pursuit of power efficient buildings involves cost effective HVAC system design. This may include systems for domestic water heating, architectural enclosure, HVAC, lighting, and vertical transportation. The loads for your HVAC systems will come primarily from 5 different sources including lighting (cooling), the construction envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load will be a purpose of either the mechanisms required to be able to introduce it in a space and control contaminant concentration or the quantity of folks which will use the space. In the vast majority of climates from the eastern and southwestern areas of the usa, to minimize outter ventilation helps save energy whenever the

outside air is either humid and warm or very cold.
Manipulating the ventilation rate is going to be dependant on occupancy which is known as a kind of demand control ventilation. It is a everyday sort of energy conservation approach that is utilized for spaces with irregular or heavy occupancy. Having cooling and heating loads reduced as low as possible can be accomplished by utilizing a high performance building envelope, occupancy sensors, and high performance lighting that utilize daylight response of lighting controls.

Chicago HVAC Engineering services vs HVAC Techs

If you’ve ever discussed the distinction between a HVAC Engineers versus HVAC Technicians, then read on:

Chicago HVAC engineers would be the people that watch over installing of air cooling systems for both residential and commercial buildings. They spend lots of their time in offices doing higher level organization and arranging of installations however they do also go to job sites every once in awhile.

But, HVAC technicians in Chicago often do a lot of hands-on work  that deals with maintenance and repair. A HVAC technician may work together with an engineer to do a number of the installation task, specifically for smaller jobs. Generally HVAC techs do much more travel and may spend a lot of time changing filters, identifying leaks, doing recharges or decommissioning old and outdated systems that use old refrigerants.

HVAC engineers could have a chance to make more decisions about systems that are used, and so they are the folks that would offer assistance with the most sensible refrigerants and which systems would best suit a much bigger building. In the industry, there is some competition between ‘the suits’ and ‘the ones which get their hands dirty’, but the two jobs require an excellent expertise in how air cooling is proven to work. Lately huge crowds have been reading our website searching for HVAC Conference 2019 Chicago. Nevertheless, the goal of our company is to become the to go to organization for those searching for a HVAC Chicago and or any of our other services including MEP Engineering Engineering services. We ask that anybody searching for additional info about our Heating and Air Conditioning (HVAC) Engineering Firm in Chicago Illinois stops by at our blog!

Latest Blog Article Related to HVAC Chicago

A Construction Engineers Guide to Selecting the Right Type of Electrical Raceway: Metallic Conduit Options

Fire Protection Engineering UMD

Electrical conductors are subject to stringent installation requirements, established in the NFPA National Electrical Code and the NYC Electrical Code, to which construction engineers must abide. There are many logical reasons for this.

A conductor in the open is vulnerable to physical damage, and at the same time it represents a high risk of electric shock or fire. Therefore, conductors must have both electrical insulation and physical protection; unless a conductor is armored or sheathed, physical protection is typically provided by electrical conduit.

The different types of electrical conduit in the market differ in terms of material used and flexibility: conduit can be either metallic or non-metallic, as well as rigid or flexible. Although each type is intended for different applications, there is some overlap between approved uses. Therefore, design engineers must often choose between many valid options for a given application. Sizing is very important: undersized conductors cannot accomplish their function, but oversized conductors represent a waste of capital.

This article will provide an overview of the main types of metallic electrical conduit and their applications. Keep in mind this is a general guide, not a replacement for NFPA and NYC codes. The technical requirements explained here are very general – make sure you check the applicable codes before specifying conduit in any project. There are five main types of metallic conduit, which are summarized in the following table:

AbbreviationFull Name
EMT
RMC
IMC
FMC
LFMC
Electrical Metallic Tubing
Rigid Metal Conduit
Intermediate Metal Conduit
Flexible Metal Conduit
Liquidtight Flexible Metal Conduit

Electrical Metallic Tubing (EMT)

EMT is a lightweight but rigid metallic raceway option. If offers less mechanical protection compared with IMC and RMC, but it has the advantage of being easy to bend, which is beneficial when construction engineers must build the electrical raceway around obstacles or corners. The most commonly used EMT materials are galvanized steel and aluminium.

Since EMT is not normally threaded at its ends, fittings use perpendicular screws or threaded compression unions. Set-screw fittings are cheaper, but compression fittings offer a tighter connection.

Electrical codes do not allow EMT in applications where electrical raceway is exposed to significant physical damage or corrosion, or in occupancies classified as hazardous locations.

Rigid Metal Conduit (RMC)

RMC is the heavy-duty option, with the thickest walls among all metallic conduit options. This type of conduit is the standard choice for demanding environments, offering both mechanical and chemical resistance. RMC is normally made from galvanized steel, stainless steel, red brass or aluminium. All types are suitable for corrosive environments, but additional protection may be required in the case of aluminium RMC.

RMC offers far greater mechanical resistance than EMT, but this comes with a much higher price tag. Working with RMC also involves more technical complexity, requiring specialized equipment for cutting and threading.

Intermediate Metal Conduit (IMC)

As implied by its name, IMC is the intermediate option, thicker than EMT but thinner than RMC. However, IMC uses a high-strength steel alloy to offer physical protection comparable to that of RMC, in spite of the reduced wall thickness. IMC can be used in the same applications where RMC is allowed, and it only has one limitation: while RMC trade sizes range from ½” to 6”, IMC only goes from ½” to 4”. Therefore, you must use RMC in heavy-duty applications where the specified conduit size exceeds 4”.

It is important to note that, although IMC is thinner than RMC, the external diameter is the same for both types of conduit. As a result, IMC has slightly more internal space to handle conductors.

Flexible Metal Conduit (FMC) and Liquidtight Flexible Metal Conduit (LFMC)

In the electrical trade, FMC is normally called “greenfield” or “flex”. The body of FMC uses an interlocked steel spiral to offer decent mechanical protection but also flexibility. FMC is typically used when raceway ends require flexibility for connection, or when a connection to vibrating equipment that may cause fatigue failure in a rigid connection. LFMC is basically FMC with a liquid-tight coating, typically made from a thermoplastic material.

Additional Recommendations from Construction Engineers

Keep in mind that conduit diameter is determined by conductor diameter, which in turn is determined by the load on the circuit. Therefore, energy efficiency measures can lead to conductor and conduit savings in new constructions. The savings from using a smaller conductor and conduit diameter may not be noticeable for a single branch circuit, but the savings add up in a large project such as a high-rise building.

MEP design software is also a very powerful tool to reduce conductor and conduit costs. When circuit routes are specified as short as possible, material requirements are reduced, along with the associated man-hours from associated construction engineers and others.

Top Ssearch Queries Related to HVAC Chicago