HVAC Elmwood Park Chicago 2018-11-25T10:05:57+00:00

HVAC Elmwood Park Chicago | Expert Energy Efficient System Designs

Construction Engineering Degree
Contact Us

Don’t be fooled by our NY-Engineers.Com is your best bet if you are looking for Full Service Air Conditioning, Heating & Cooling (HVAC) Engineering Firm in Chicago Illinois. We are not only an HVAC Chicago but also a leading provider of Protection Engineering services near Elmwood Park Chicago. Call us at 312 767-6877

Contact Us

As of late huge crowds have been visiting our site in search of Fire Protection Engineering in the Chicago area. This is due primarily due to the following we have develop in this kind of work. With that said, a lot of builders from Darien to Niles, are not aware that NY-Engineers.Com is also the ideal choice for anyone searching for HVAC Firm in Chicago

The search for power efficient buildings involves energy-efficient HVAC system design. This can include systems for HVAC, lighting, architectural enclosure, domestic water heating, and vertical transportation. The loads for the HVAC systems may come primarily from 5 different places including lighting (cooling), the construction envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load will certainly be a purpose of either the instruments needed in order to introduce it into a space and control contaminant concentration or the amount of folks that may fill the room. In nearly all climates in the southwestern and eastern regions of america, to lower outter air movement will save energy whenever the outer air is either warm and humid or very cold.
Manipulating the ventilation rate is going to be determined by occupancy which is called a type of demand control ventilation. This is a everyday sort of energy conservation strategy that is used for spaces with irregular or dense occupancy. Having cooling and heating loads reduced as low as possible can be achieved by using a high performance building envelope, occupancy sensors, and performance lighting that uses daylight response of lighting controls.

Chicago HVAC Engineers versus HVAC Technicians

If you have ever wondered about the difference between a HVAC Engineers vs HVAC Engineers, then keep reading:

HVAC engineers would be the people who oversee setting up of air cooling systems both for commercial and residential buildings. They spend a lot of their work in offices doing advanced level organization and arranging of installations however they do also see job sites every so often.

In comparison, HVAC technicians in Chicago often do a lot of the hands-on work with maintenance and repair. A HVAC tech may work with or for an engineer to perform a few of the installation work, specifically on smaller jobs. On the whole HVAC technicians do much more travel and could spend a lot of time changing filters, identifying leaks, doing recharges or getting rid of old and outdated systems that utilize old refrigerants.

HVAC engineers could have the chance to make more decisions about systems that are being used, and they are the individuals who would offer advice about by far the most sensible refrigerants and which systems would work best with a larger building. In the trade, there is certainly some rivalry between ‘the suits’ and ‘the ones that get their hands dirty’, but both jobs require an excellent familiarity with how air cooling works. As of late many individuals have been reading our sites looking for HVAC Technician Jobs Chicago. With that said, the goal of our organization is to become the number one choice for anyone looking for a HVAC Company in Chicago and or any of our other services including MEP Engineering Engineering services. We ask that everybody searching for additional information about our Air Conditioning, Heating & Cooling (HVAC) Engineering Firm in Chicago Illinois visits at our Building Commissioning blog

Article Related to HVAC Chicago

How Construction Engineers are Improving HVAC Efficiency in Commercial Buildings with Variable Frequency Drives

Value Engineering Architecture

HVAC systems come in various configurations that differ significantly from each other. For example, an air conditioning system based on packaged rooftop units is drastically different from a chiller plant. However, HVAC installations have a common denominator: they use electric motors that are subject to variable loads. Regardless of whether these motors are used to drive compressors, water pumps or fans, construction engineers understand that there is a great opportunity to save energy by optimizing part-load operation.

In general, running a motor at partial speed is more energy-efficient than running it intermittently at full speed.

  • Intermittent operation only provides linear savings. For example, a cooling tower fan with a duty cycle of 80% consumes 20% less energy than an identical fan operating full-time.
  • Reducing motor speed provides cubic savings.. On the other hand, slowing down a fan to 80% speed reduces energy consumption by nearly 50%. The average airflow is the same as that of a fan running at full power 80% of the time, but savings are boosted significantly thanks to speed control.

Speed control can be accomplished with variable-frequency drives (VFD), and they have a broad range of applications in HVAC systems due to the cyclic nature of loads. It is important to note that VFDs are also known as variable-speed drives (VSD), adjustable-frequency drives (AFD) or adjustable-speed drives (ASD).

Fractional horsepower motors in small-scale HVAC systems can also achieve significant savings with speed control. The main difference here is that electronically commutated motors (ECMs) are more cost-effective than VFDs in these applications.

Ask a Construction Engineering Expert: How Does Variable Frequency Drive Work?

As explained by electrical engineering textbooks, the speed of an electric motor is defined by the power supply frequency and its internal construction. For example, a motor running at 1800 RPM with the 60 Hz USA power supply would run at 1500 RPM in the UK, where the frequency is 50 Hz. Thus, if a motor is suitable for operation at reduced frequency, its speed can be ramped down during part load conditions to achieve energy savings. VFDs are connected between the power supply and the motor, adjusting voltage and frequency as a means of speed control.

In applications where only single-phase power is available, VFDs can be used to integrate three-phase motors while achieving the energy efficiency benefits: there are models capable of producing a three-phase voltage from a single-phase input, while adjusting magnitude and frequency to control motor speed.

In addition to improving energy efficiency, VFDs allow motors to be soft-started by gradually ramping up the voltage and frequency, as opposed to directly applying full voltage at 60 Hz. Electric motors draw from five to eight times their rated current when started directly, and the voltage drop that results from the inrush current may damage sensitive equipment.

The main limitation of VFDs is that they produce a phenomenon called harmonic distortion, where high-frequency currents are induced in branch circuits. However, this can be controlled with a properly-specified harmonic filter; this device absorbs current distortions at the point of consumption, preventing their propagation throughout the installation.

VFD Applications in HVAC Systems

In most cases, VFDs are deployed by construction engineers in HVAC systems to control the speed of blower fans, pumps or compressors.

Cooling Tower Fans

The main purpose of a cooling tower is removing the heat from a water circuit, which may be used in turn for process cooling or for a chiller plant. Cooling towers use fans to establish an airflow, improving heat removal through convection. These are open discharge fans, where there is no ductwork creating resistance to airflow; hence, the savings opportunity through speed control is significant.

When a VFD is deployed for a cooling tower fan, speed is normally controlled based on water temperature. Rather than cycling the fan on and off, it can be driven at reduced speed so that the water returning to the chiller or process is kept at a constant temperature – as previously explained, reduced-speed operation is far more efficient than intermittent operation at full speed.

Air-Handling Units and Packaged Rooftop Units

Unlike the fans in cooling towers, those used in AHUs and packaged RTUs blow air into a duct system, which offers higher resistance and requires a specific static pressure and airflow to be established. These ducts may have several outlets with variable-air-volume (VAV) boxes, where airflow is controlled individually for each zone with a damper.

Without a VFD, the blower fan in the AHU or RTU operates at full speed, and each VAV box is adjusted individually. This is an inefficient approach, however – if neither of the VAV boxes is fully open, energy is being wasted in the form of extra pressure. On the other hand, if the blower is equipped with a VFD, an interesting energy-saving strategy becomes possible:

  • Blower speed can be gradually reduced while VAV boxes are opened incrementally, to keep the airflow and temperature constant.
  • The temperature of different zones is unaffected but pressure is reduced, saving energy.
  • Speed reduction continues until one of the VAV boxes reaches the fully open position. At this point it is not possible to reduce speed further without affecting indoor temperatures.

There is also a comfort benefit with this control strategy: the reduced pressure drop translates into less noise, making indoor environments more comfortable.

Speed Control for Water Pumps

Water circuits are a key element of many HVAC installations, including those that use chillers, boilers and water-source heat pumps. Since HVAC loads are variable, it is often necessary to adjust the water flow depending on total system load. There are three main ways to achieve this:

  • Choke Valve-A choke valve is installed in line with the flow, and as implied by its name it regulates flow by closing partially. This control method is simple, but the resulting pressure loss represents a considerable waste of energy.
  • Recirculation Valve-With this approach a valve is installed on a parallel recirculation circuit, and it is opened gradually to divert a part of the water flow, reducing the flow in the main circuit. In this case, however, there is also a significant energy loss because the recirculated water represents pumping power.
  • Pump Speed Control– The most energy efficient approach is to install a VFD on the pump motor. If a reduced water flow is required, it is just a matter of reducing the pump speed accordingly. With no pressure or recirculation losses, the savings achieved are significant. This setup also uses a choke valve for convenience, but it is normally kept in the fully open position, since the VFD regulates flow.

Chillers with Variable-Speed Compressors

In chilled water air conditioning systems, the chiller is by far the piece of equipment with the highest energy consumption. Therefore, installing the most efficient chiller model that can be afforded is highly recommended.

Energy efficient chillers have helical rotary compressors, capable of adjusting their speed with a VFD, depending on cooling needs. Some models may feature multiple individual compressors to achieve enhanced flexibility and increased part-load efficiency.

When a chiller is highly efficient, the control strategy is normally based on maximizing its capacity rather than running it at the lowest possible set point. The savings achieved by reducing the load on complementary systems tend to be far greater than the extra consumption at the chiller. There are exceptions, of course, and only monitoring and control can offer the correct answer 100% of the time.

Integrating the Entire HVAC System

Equipping all motors in an HVAC system with VFDs is a first step towards energy efficiency, but the best results can only be achieved with central control system, capable of assessing building conditions and adjusting HVAC set points in real time.

The interaction between a chiller and a cooling tower is a great example of how control engineering and VFDs can be applied to HVAC installations:

  • Reducing the cooling tower fan speed increases the cooling load on the chiller.
  • The reverse also applies: reducing refrigeration power at the chiller may require more heat to be rejected by the cooling tower.

If the chiller has a high efficiency, the best option in most scenarios is reducing the cooling tower load. However, only a control system can balance the operation of both components in real time. Ideally, the control system should be able to determine the set point for each individual VFD so that power consumption is minimized at the total system level.

Of course, the performance of an HVAC system starts from the design phase. For optimal results, make sure you work with licensed and qualified construction engineers and other HVAC professionals. Installing an efficient and automated HVAC system from the start is much less expensive than upgrading an existing installation.

Top Searches Related to HVAC Chicago