HVAC Engineering Kilbourn Park Chicago, IL2018-10-15T21:46:16+00:00

What Can Our HVAC Engineers in Kilbourn Park Chicago Do For You?

Contact Us!

When you’re looking for a competent HVAC Chicago? Your best bet is to reach out to is NY-Engineers.Com. Not only for HVAC Firms in Chicago but also MEP Engineering and Sprinkler Design Engineering in or near Kilbourn Park Chicago. Call 312 767.6877

Contact Us!
Construction Engineering Vs Civil Engineering

Since coming to market many building owners throughout Rockville Centre, New York already know that NY-Engineers.Com is the engineering firm to contact when you’re searching for Value Engineering in New York. What many local developers have not realized is the NY-Engineers.Com is also your top choice if you’re searching for HVAC Engineering services in Kilbourn Park Chicago, IL. If you want to understand more about what Kilbourn Park Chicago HVAC design engineers do? This can be a unique job with an an extensive list of duties. An HVAC design personel will be asked to go through numerous concundrums to eliminate the basic issue. This career calls for superior talent, proficieny, and the opportunity to handle time wisely.

Once an HVAC personel is certified to work, they may be hired by an engineering business and start to functions on many heating, cooling, and refrigeration systems. Their role is usually to draw up new and additional options according to their customer’s requirements. Every customer will have a unique set of wants whether it has to do with building codes or individual performance anticipations. Making use of this information, the engineer goes on a trek towards creating something which is eco-friendly, energy-efficient and well suited for the location it might be utilized in – (residential/industrial/commercial). They are generally in charge of the original creations and managing the particular installation.

On the whole, an HVAC design engineer in Kilbourn Park Chicago is going to be seen working with a design company or even in a consulting team based on their many years of skill. A great deal of engineers switch right into a consulting job since they mature and gain a better knowledge of what is expected of them.

Comparison: HVAC Technician vs HVAC Engineer

HVAC Engineer and HVAC Technician are frequently mistaken for the other. Nevertheless, they have separate job functions in relation to handling HVAC systems. It is important to are aware of the contrast both as being a parton also as an expert

An HVAC technician in Kilbourn Park Chicago is a more practical job, which implies they are usually seen visiting a owner’s home to inspect their current system. They frequently keep up with the installations, repairs, and general care which is required every once in awhile. Almost all of their job is done in conjunction with the buyer, meaning they should understand how to connect with people in the correct manner.

Having an HVAC engineer, they are responsible for creating a fresh HVAC system and making sure it meets what a client needs. It has to fit just what the property owner wants if it involves their setup, property, or anything else linked to new system. They are also introduced to consult on HVAC creations to make certain things are all in line with the latest standards. That is why they may end up spending time in consulting firms or at local engineering businesses. This is actually the distinction between these career paths; HVAC Technician vs HVAC Engineer. There is a great possibility you would like additional details about the HVAC Engineering services in Kilbourn Park Chicago, IL by NY-Engineers.Com we invite you to visit at our Kilbourn Park Chicago Building Commissioning blog.

Kilbourn Park Chicago HVAC Engineering Related Blog

Architectural Engineers Detail Ventilation System Configurations

Construction Engineering Courses

Human activity generates a broad range of compounds that become dangerous in high-enough concentrations, and pollutants from outdoor sources can also degrade indoor air quality. Architectural engineers are often charged with the job of preventing this from occurring as much as possible.

Ventilation systems keep these substances at low levels by constantly renewing indoor air, and they also contribute to keeping moisture within the range of 30 to 60 percent as recommended by ASHRAE. Without ventilation, it would not be possible to keep indoor environments comfortable and healthy.

Natural ventilation relies on wind currents, outdoor temperature and other weather conditions to supply fresh air. The advantage of natural ventilation is that it comes for free, and in new buildings it is possible to optimize architectural design to maximize its effects. However, natural ventilation is uncontrollable, and generally insufficient to fully meet the requirements of modern buildings.

Normally, to meet ASHRAE standards and local building codes, mechanical ventilation must be deployed. Depending on their configuration, whole-house ventilation systems can be classified into three main types:

  • Exhaust ventilation systems, which only use extractor fans.
  • Supply ventilation systems, which only use injector fans.
  • Balanced ventilation systems, which use both injector and extractor fans.

Balanced systems can be enhanced with energy-recovery ventilation, a technology that exchanges energy between the supply and exhaust airflows to maximize performance and minimize the overall running cost of the system.

Exhaust Ventilation Systems

As implied by their name, exhaust ventilation systems only deploy extractor fans. When the system starts to run, it creates a negative pressurization effect in occupied spaces, drawing in fresh outdoor air to renew that which is exhausted. It is important to note, however, that exhaust ventilation is not possible in air-tight buildings, since outdoor air must be allowed to leak in. If the building envelope has been tightened with caulking and weather stripping, exhaust ventilation must be complemented with intake vents.

Exhaust ventilation systems have a single set of fans and ducts, which makes them affordable while reducing their installation time and cost. Energy expenses are relatively low because there is only one set of fans in operation, and maintenance is simplified as well. The system layout can be designed to target specific areas where pollutants are generated, ensuring they are removed before they spread indoors.

Exhaust ventilation generally achieves the best results in cold and dry climates, where outdoor air does not require dehumidification. It is not recommended for tropical and mixed climates, because warm and humid outdoor air is drawn in without control, driving up cooling and dehumidification expenses. Also, keep in mind that depressurization draws air from all surrounding spaces, with little control over pollutant content. In general, architectural engineers recommend exhaust ventilation for cold weather, and when outdoor air pollution is low.

Another risk of exhaust ventilation is backdraft, which occurs when a combustion-based appliance suddenly draws in a lot of air, potentially causing a flashover. Since exhaust ventilation causes negative pressurization and does not control air supply, there is an increased chance of backdraft.

Supply Ventilation Systems

Supply ventilation only uses injector fans, pressurizing rooms and causing indoor air to leak out constantly. The main advantage of supply ventilation is control, since outdoor air can be filtered, humidified or dried as needed. In addition, the pressurization effect prevents the inflow of pollutants from surrounding spaces or from outdoors.

Another benefit of supply ventilation is that it eliminates the risk of backdraft from combustion appliances due to positive pressurization. Installation, operation and maintenance expenses are also reduced thanks to the simple system configuration.

Supply ventilation is better suited for tropical or mixed climate conditions, where dehumidification and filtering are often required. This configuration tends to cause trouble in cold weather, since the pressurization effect can cause condensation of indoor air humidity, leading to moisture accumulation and its common side-effects: furniture damage and the proliferation of mold, bacteria and dust mites.

Balanced Ventilation Systems

A balanced ventilation system is the result of combining exhaust and supply ventilation: both airflows can be controlled, providing the benefits of both system configurations. Of course, this comes at a higher installation and operation cost, since there are now two sets of fans and ducts.

Balanced ventilation is suitable for all weather conditions, and airflows can be adjusted to provide any pressurization effect as required – positive, negative or neutral. The recommended locations for each set of ducts are the following:

  • Supply ducts should focus on areas where occupants spend most of their time, including living rooms and bedrooms. This ensures that these areas always have a supply of fresh and clean air.
  • Exhaust ducts should focus on areas where moisture and humidity are released frequently, such as kitchens, bathrooms, laundries and boiler rooms.

Of course, it is possible to install supply and exhaust rooms for every room, but system costs are increased significantly. With the approach presented above, system costs are optimized without compromising performance.

Energy-Recovery Ventilation: Architectural Engineers Improve the
Efficiency of Balanced Ventilation

Energy-recovery ventilation consists on exchanging energy between the supply and exhaust air, so that overall HVAC costs are minimized. These systems can be classified into two main types:

  • Heat-Recovery Ventilation (HRV)systems only exchange heat between the supply and exhaust airflows.
  • Enthalpy-Recovery Ventilation (ERV)systems exchange both heat and moisture.

Summer Operation

In the summer, outdoor air typically requires cooling and dehumidification. However, when air is exhausted, it is still cooler and drier than the supply air; therefore, a part of the energy used for cooling and dehumidification is lost.

  • The use of a heat exchanger (HRV) can improve energy efficiency: the exhaust air is used to precool the supply air without mixing both airstreams.
  • If an ERV system is used, moisture is also transferred from the supply air to the exhaust air, further improving air-conditioning efficiency because there is less moisture to remove.

Winter Operation

During the winter, HVAC needs are reversed because outdoor air typically requires heating and humidification. The operating principle of HRV and ERV is the same, but the direction in which heat and humidity are transferred is inverted.

  • The exhaust air is warmer, and the heat exchanger captures a part of that thermal energy to preheat the supply air.
  • If ERV is used, moisture is also retrieved from the exhaust air and provided to the supply air.

General Recommendations for HRV and ERV

It is important to note that HRV and ERV systems are significantly more complex than the ventilation systems presented before. They can only be installed and serviced by qualified personnel, which increases their cost of ownership. Compared with a basic balanced ventilation system, HRV and ERV systems have a higher running cost, but overall HVAC expenses are reduced.

HRV and ERV systems increase in effectiveness where temperature  and moisture extremes are reached during the summer or winter, or when heating fuel costs are high. Their benefits are diminished under moderate weather conditions, where the added running cost may be higher than the savings achieved – balanced ventilation is a better alternative in these cases.

Spot Ventilation: A Complement for Whole-House Ventilation

Spot ventilation consists on using exhaust fans to extract pollutants and humidity at the room where they are released, preventing them from being spread throughout other indoor spaces. In residential settings, spot ventilation is most commonly used in bathrooms and kitchens to meet the minimum exhaust air levels established in both the area mechanical codes and ASHRAE standards:

  • Bathrooms require 50 cfm of intermittent ventilation or 20 cfm of continuous ventilation.
  • Kitchens require 100 cfm or intermittent ventilation or 25 cfm of continuous ventilation.

Spot ventilation can be a great complement for supply ventilation systems, removing pollutants from key areas. This combination provides many of the benefits of a balanced ventilation system without having to install a full set of exhaust fans and ducts. According to experienced architectural engineers, the only disadvantage of this combination is that HRV and ERV systems are unfeasible, since there is no point where heat or moisture can be exchanged between airflows.

Popular searches related to HVAC Engineering in Kilbourn Park Chicago, IL.