HVAC Engineering North Lawndale Chicago, IL2018-10-27T18:59:18+00:00

What Can Our HVAC Engineers in North Lawndale Chicago Do For You?

Contact Us!

When you’re looking for a dependable HVAC Firms in Chicago? The one to go to is NY Engineers. Not only for HVAC Engineering in Chicago but also Value Engineering and Sprinkler Engineering throughout North Lawndale Chicago. Contact us at (+1) 312 767.6877

Contact Us!
Value Engineering Process Steps

Since 2011 the majority of construction companies throughout Selden, NY already know that New York Engineers is the engineering company to call when you are searching for MEP Engineering in New York. What a lot local property owners have not realized is the New York Engineers is also your best choice if you’re searching for HVAC Engineering services in North Lawndale Chicago, IL. If you want to understand more about what North Lawndale Chicago HVAC design engineers do? This can be an exceptional trade which inclides a detailed set of responsibilities. An HVAC design contractor will be asked to go through numerous concundrums to work out the underlying issue. This career calls for superior talent, professionalism, and the ability to deal with time cleverly.

The moment an HVAC personel is certified to function, they will get employed by an engineering business and start to work on many heating, cooling, and refrigeration systems. Their role would be to create new and alternative choices in line with their client’s requirements. Every client is going to have an exclusive set of needs whether it has to do with building codes or personal performance anticipations. Using all of this info, the engineer sets off on a ride towards building something which is eco-friendly, energy-efficient and suitable for the place it is going to be utilized in – (industrial, commercial or residential. They usually are responsible for the original drawings and managing the specific installation.

Generally, an HVAC engineer in North Lawndale Chicago will likely be seen working with a design company or even in a consulting firm based on their many years of skill. A great deal of engineers move into a consulting job since they mature and obtain a better comprehension of what’s required of them.

Comparing HVAC Engineer Versus HVAC Technician

HVAC Technician and HVAC Engineer tend to be mistaken for one another. However, they have got different tasks with regards to working with HVAC systems. It’s vital that you understand the contrast both as being a customer and as a specialist

An HVAC technician in North Lawndale Chicago carries a more direct job, meaning they are usually seen visiting a customer’s home to check out their present system. They generally handle the installations, repairs, and general keep that’s needed ever so often. Nearly all of their jobs are done together with the customer, meaning they must understand how to connect to people in the right way.

With the HVAC engineer, they are responsible for designing a brand new HVAC system and making sure it fits just what a customer is after. It must fit precisely what the home owner needs if it involves their setup, property, or anything else associated with new system. They are also brought in to check on HVAC designs to make sure things are in line with the latest standards. This is why they may wind up passing time in consulting firms or at local engineering businesses. This is the distinction between both of these occupation; HVAC Technician Versus HVAC Engineer. Even with all of this information you would like more info on the HVAC Engineering services in North Lawndale Chicago, IL by NY-Engineers.Com you should visit at our North Lawndale Chicago Mechanical Engineering blog.

North Lawndale Chicago HVAC Engineering Related Article

Architectural Engineers Detail Ventilation System Configurations

M2e Engineering

Human activity generates a broad range of compounds that become dangerous in high-enough concentrations, and pollutants from outdoor sources can also degrade indoor air quality. Architectural engineers are often charged with the job of preventing this from occurring as much as possible.

Ventilation systems keep these substances at low levels by constantly renewing indoor air, and they also contribute to keeping moisture within the range of 30 to 60 percent as recommended by ASHRAE. Without ventilation, it would not be possible to keep indoor environments comfortable and healthy.

Natural ventilation relies on wind currents, outdoor temperature and other weather conditions to supply fresh air. The advantage of natural ventilation is that it comes for free, and in new buildings it is possible to optimize architectural design to maximize its effects. However, natural ventilation is uncontrollable, and generally insufficient to fully meet the requirements of modern buildings.

Normally, to meet ASHRAE standards and local building codes, mechanical ventilation must be deployed. Depending on their configuration, whole-house ventilation systems can be classified into three main types:

  • Exhaust ventilation systems, which only use extractor fans.
  • Supply ventilation systems, which only use injector fans.
  • Balanced ventilation systems, which use both injector and extractor fans.

Balanced systems can be enhanced with energy-recovery ventilation, a technology that exchanges energy between the supply and exhaust airflows to maximize performance and minimize the overall running cost of the system.

Exhaust Ventilation Systems

As implied by their name, exhaust ventilation systems only deploy extractor fans. When the system starts to run, it creates a negative pressurization effect in occupied spaces, drawing in fresh outdoor air to renew that which is exhausted. It is important to note, however, that exhaust ventilation is not possible in air-tight buildings, since outdoor air must be allowed to leak in. If the building envelope has been tightened with caulking and weather stripping, exhaust ventilation must be complemented with intake vents.

Exhaust ventilation systems have a single set of fans and ducts, which makes them affordable while reducing their installation time and cost. Energy expenses are relatively low because there is only one set of fans in operation, and maintenance is simplified as well. The system layout can be designed to target specific areas where pollutants are generated, ensuring they are removed before they spread indoors.

Exhaust ventilation generally achieves the best results in cold and dry climates, where outdoor air does not require dehumidification. It is not recommended for tropical and mixed climates, because warm and humid outdoor air is drawn in without control, driving up cooling and dehumidification expenses. Also, keep in mind that depressurization draws air from all surrounding spaces, with little control over pollutant content. In general, architectural engineers recommend exhaust ventilation for cold weather, and when outdoor air pollution is low.

Another risk of exhaust ventilation is backdraft, which occurs when a combustion-based appliance suddenly draws in a lot of air, potentially causing a flashover. Since exhaust ventilation causes negative pressurization and does not control air supply, there is an increased chance of backdraft.

Supply Ventilation Systems

Supply ventilation only uses injector fans, pressurizing rooms and causing indoor air to leak out constantly. The main advantage of supply ventilation is control, since outdoor air can be filtered, humidified or dried as needed. In addition, the pressurization effect prevents the inflow of pollutants from surrounding spaces or from outdoors.

Another benefit of supply ventilation is that it eliminates the risk of backdraft from combustion appliances due to positive pressurization. Installation, operation and maintenance expenses are also reduced thanks to the simple system configuration.

Supply ventilation is better suited for tropical or mixed climate conditions, where dehumidification and filtering are often required. This configuration tends to cause trouble in cold weather, since the pressurization effect can cause condensation of indoor air humidity, leading to moisture accumulation and its common side-effects: furniture damage and the proliferation of mold, bacteria and dust mites.

Balanced Ventilation Systems

A balanced ventilation system is the result of combining exhaust and supply ventilation: both airflows can be controlled, providing the benefits of both system configurations. Of course, this comes at a higher installation and operation cost, since there are now two sets of fans and ducts.

Balanced ventilation is suitable for all weather conditions, and airflows can be adjusted to provide any pressurization effect as required – positive, negative or neutral. The recommended locations for each set of ducts are the following:

  • Supply ducts should focus on areas where occupants spend most of their time, including living rooms and bedrooms. This ensures that these areas always have a supply of fresh and clean air.
  • Exhaust ducts should focus on areas where moisture and humidity are released frequently, such as kitchens, bathrooms, laundries and boiler rooms.

Of course, it is possible to install supply and exhaust rooms for every room, but system costs are increased significantly. With the approach presented above, system costs are optimized without compromising performance.

Energy-Recovery Ventilation: Architectural Engineers Improve the
Efficiency of Balanced Ventilation

Energy-recovery ventilation consists on exchanging energy between the supply and exhaust air, so that overall HVAC costs are minimized. These systems can be classified into two main types:

  • Heat-Recovery Ventilation (HRV)systems only exchange heat between the supply and exhaust airflows.
  • Enthalpy-Recovery Ventilation (ERV)systems exchange both heat and moisture.

Summer Operation

In the summer, outdoor air typically requires cooling and dehumidification. However, when air is exhausted, it is still cooler and drier than the supply air; therefore, a part of the energy used for cooling and dehumidification is lost.

  • The use of a heat exchanger (HRV) can improve energy efficiency: the exhaust air is used to precool the supply air without mixing both airstreams.
  • If an ERV system is used, moisture is also transferred from the supply air to the exhaust air, further improving air-conditioning efficiency because there is less moisture to remove.

Winter Operation

During the winter, HVAC needs are reversed because outdoor air typically requires heating and humidification. The operating principle of HRV and ERV is the same, but the direction in which heat and humidity are transferred is inverted.

  • The exhaust air is warmer, and the heat exchanger captures a part of that thermal energy to preheat the supply air.
  • If ERV is used, moisture is also retrieved from the exhaust air and provided to the supply air.

General Recommendations for HRV and ERV

It is important to note that HRV and ERV systems are significantly more complex than the ventilation systems presented before. They can only be installed and serviced by qualified personnel, which increases their cost of ownership. Compared with a basic balanced ventilation system, HRV and ERV systems have a higher running cost, but overall HVAC expenses are reduced.

HRV and ERV systems increase in effectiveness where temperature  and moisture extremes are reached during the summer or winter, or when heating fuel costs are high. Their benefits are diminished under moderate weather conditions, where the added running cost may be higher than the savings achieved – balanced ventilation is a better alternative in these cases.

Spot Ventilation: A Complement for Whole-House Ventilation

Spot ventilation consists on using exhaust fans to extract pollutants and humidity at the room where they are released, preventing them from being spread throughout other indoor spaces. In residential settings, spot ventilation is most commonly used in bathrooms and kitchens to meet the minimum exhaust air levels established in both the area mechanical codes and ASHRAE standards:

  • Bathrooms require 50 cfm of intermittent ventilation or 20 cfm of continuous ventilation.
  • Kitchens require 100 cfm or intermittent ventilation or 25 cfm of continuous ventilation.

Spot ventilation can be a great complement for supply ventilation systems, removing pollutants from key areas. This combination provides many of the benefits of a balanced ventilation system without having to install a full set of exhaust fans and ducts. According to experienced architectural engineers, the only disadvantage of this combination is that HRV and ERV systems are unfeasible, since there is no point where heat or moisture can be exchanged between airflows.