HVAC Engineering Ukrainian Village Chicago, IL2018-10-29T15:31:08+00:00

What Can Our HVAC Engineers in Ukrainian Village Chicago Do For You?

Contact Us!

When you’re searching for a competent HVAC Chicago? Your best bet is to call is NY Engineers. Not only for HVAC Engineering in Chicago but also Electrical Engineering and Protection Engineering in or near Ukrainian Village Chicago. Call us at (312) 767.6877

Contact Us!
Value Engineering Process Steps

Since 2011 a lot of building owners throughout Eastchester, NY already know that New York Engineers is the engineering firm to contact when you are searching for MEP Engineering in New York City. What a lot local real estate investors have not realized is the New York Engineers is also your top choice if you are searching for HVAC Engineering services in Ukrainian Village Chicago, Illinois. Those who need additional details on what Ukrainian Village Chicago HVAC design engineers do? This is an exclusive profession that come with a detailed set of obligations. An HVAC design contractor will be asked to get through numerous concundrums to settle the basic issue. This task calls for superior expertise, professionalism, and the capability to manage time prudently.

Once an HVAC personel is licensed to work, they may be hired by an engineering business and start to work on various heating, cooling, and refrigeration systems. Their responsibility is to design new and/or replacement choices in line with their client’s requirements. Every single customer will have an exclusive set of wishes whether or not it involves developing codes or individual performance prospects. Making use of this data, the engineer goes on a journey towards making something that’s energy-efficient, eco-friendly and perfect for the setting it might be placed in – (residential/commercial/industrial). They are generally liable for the primary creations and managing the exact installation.

In general, an HVAC design engineer in Ukrainian Village Chicago will probably be seen working with a design business or even in a consulting team according to their years of expertise. Many engineers switch into a consulting job because they grow older and gain a better knowledge of what’s required of them.

Comparison: HVAC Technician Versus HVAC Engineer

HVAC Technician and HVAC Engineer are frequently mistaken for one another. Yet, they have separate job functions with regards to overseeking HVAC systems. It’s crucial that you be aware of the difference both as a client also as an expert

An HVAC technician in Ukrainian Village Chicago has a more hands-on job, meaning they are often seen visiting a customer’s home to look at their present system. They often times take care of the installations, repairs, and overall care that’s required from time to time. Almost all of their work is done together with the buyer, which suggests they have to understand how to connect to people in the correct manner.

With an HVAC engineer, they are accountable for designing a brand new HVAC system and ensuring it meets what a customer needs. It needs to fit just what the home owner wants if it has to do with their setup, property, or everything associated with new system. Also, they are introduced to talk on HVAC creations to make sure things are consistent with modern standards. For this reason they are able to wind up spending some time in consulting assignments or at neighborhood engineering businesses. This is the difference between those two career paths; HVAC Technician Versus HVAC Engineer. There is only so much you can save this page if you would like more details about the HVAC Engineering services in Ukrainian Village Chicago, IL by New York Engineers we invite you to stop by at our Ukrainian Village Chicago MEP Engineering blog.

Latest Ukrainian Village Chicago HVAC Engineering Related Article

An Electrical Engineer’s Guide to Circuit Breakers: Overview and Applications

Construction Engineering Salary

Circuit breakers are fundamental elements for a safe and code-compliant electrical installation. Conductors and electrical equipment are exposed to damage and malfunction, and there is always a risk that someone may connect a device incorrectly or use it for the wrong application. Electrical engineers see these issues frequently in their line of work. These conditions can cause a device to draw current above its rated value, and the corresponding circuit breaker trips to disconnect the fault.

Before providing an overview of circuit breakers, it is important to understand the difference between the two main current conditions that cause a circuit breaker to trip.

  • An overload current occurs when a device draws current above its rated value, but not by a drastic margin. For example, a motor that is rated at 60 Amperes but drawing 75 Amperes is likely suffering an overload condition.
  • A fault current is orders of magnitude higher than the rated current of a circuit, and it occurs when a live conductor touches another at a different voltage (short circuit), or a conductive surface (ground fault). There is a high-magnitude current in both cases, since low-resistance contact is established across a voltage difference. For example, a residential circuit normally carrying 20 Amperes may experience a few thousand Amperes during a fault.

A circuit breaker must trip under both conditions, but the ideal trip response is different for each case:

  • The response to an overload current should have a time delay. Some types of equipment draw current above their rated value for short periods of time as part of their normal operation. For example, electric motors draw an inrush current up to 8 times their rated current when they start.
  • The response to a fault current should be instantaneous. These currents are not normal under any operating conditions, and they must be cleared immediately when detected.

Given this combination of performance requirements, most circuit breakers actually have two protection mechanisms in a single device. There is a thermal protection mechanism that responds to overload current, and a magnetic protection mechanism that responds to fault currents.

Thermal and Magnetic Protection

The thermal protection mechanism in a circuit breaker is based on an expanding contact: the circuit is interrupted once the contact expands beyond a certain point. The circuit breaker is calibrated so that the contact will not open below rated current, but any current conditions exceeding it will eventually cause a trip. Since current is the heat source that expands the contact, more severe overload conditions cause a faster expansion and a shorter trip time.

The magnetic protection mechanism is based on induction. Current passes through a coil inside the circuit breaker, creating a magnetic field that opens the connection. The field is too weak to trip the breaker under normal operating conditions, but high-magnitude currents cause a strong magnetic field that forces the breaker open.

Main Types of Circuit Breakers, as Explained by Electrical Engineers

Most circuit breakers found in residential and commercial buildings are either miniature circuit breakers (MCB) or molded-case circuit breakers (MCCB). MCBs are more compact as implied by their name, but MCCBs are available in much higher current ratings and come with additional performance features. MCBs are normally available with a current rating of up to 100 amperes, while MCCBs reach up to 2,500 amperes.

You will probably not find MCCBs in small homes and businesses, according to many electrical engineers, but they are common in larger constructions, such as the high rise multi-family and office buildings found throughout larger cities.

Miniature Circuit Breakers

Miniature circuit breakers come in two main versions: DIN-rail mountable MCBs can be installed along with other protection and control devices that also use DIN rails, while plug-in MCBs are inserted on load centers with specially designed slots. Keep in mind that DIN-rail MCBs are designed for standard rails, while plug-in MCBs only fit into matching load centers from the same manufacturer.

Plug-in MCBs have one to three poles, depending on the number of live conductors in the circuit being protected. DIN-rail MCBs can have up to 4 poles, in order to disconnect the neutral conductor along with the live conductors. Regardless of the type of circuit breaker, it is important to select an adequate rated current and breaking capacity.

  • The rated current is determined by the circuit being protected. Any value above this eventually trips the thermal protection mechanism.
  • The breaking capacity is the largest fault current that the unit can interrupt without suffering permanent damage. Should a fault exceed this value, there is an ultimate breaking capacity where the breaker can still clear the fault but is permanently damaged. Any fault above the ultimate breaking capacity cannot be cleared by the circuit breaker, and must be handled by a higher capacity protection system connected upstream.

Miniature circuit breakers are also classified into three types based on their response to fault currents: Type B, C and D. The type determines the threshold where the magnetic protection takes over the thermal protection, causing an instantaneous trip.

Molded Case Circuit Breakers

MCCBs are bulkier than MCBs and are available with higher current ratings. Many models also feature adjustable trip settings, allowing a very accurate protection response if a specific load needs it.

Some MCCBs also come with a removable trip unit that can be replaced with a smaller capacity unit, to recondition the breaker for a load with reduced current. However, you cannot upgrade to a larger trip unit that exceeds the frame size of the MCCB.

There are modern MCCBs that do not use the conventional thermal-magnetic mechanism, but instead use an electronic circuit that measures current and simulates the trip response. This allows a very precise adjustment of protection settings.

Two subtypes of MCCB are designed specifically for the protection needs of electric motors: Motor protection circuit breakers (MPCB) and motor circuit protectors (MCP). The main difference is that an MPCB includes both thermal and magnetic protection, while an MCP only comes with magnetic protection and needs an external overload relay to offer full protection.

Conclusion

Electrical engineers must select the right type of circuit breaker, as it is very important to ensure the safe operation of building systems that include electrical components. Undersized breakers trip continuously and disrupt equipment operation, while oversized breakers do not provide reliable protection against overload current. If an overload is not interrupted, the heating effect can damage conductor insulation and eventually cause a ground fault or short circuit.