HVAC Engineering West Elsdon Chicago, IL2018-10-06T11:13:26+00:00

What Can Our HVAC Engineers in West Elsdon Chicago Do For You?

Contact Us!

If you’re looking for a reliable HVAC Engineering in Chicago? Your best bet is to reach out to is NY-Engineers.Com. Not only for HVAC Firms in Chicago but also Electrical Engineering and Sprinkler Design Engineering throughout West Elsdon Chicago. Call (+1) 312 767.6877

Contact Us!
Construction Engineer Job Description

Since 2011 a great number of property owners throughout Lockport, New York already know that NY-Engineers.Com is the engineering company to contact when you are searching for Electrical Engineering in NYC. What many local property owners have not realized is the NY-Engineers.Com is also your top choice if you’re looking for HVAC Engineering services in West Elsdon Chicago, Illinois. If you need additional details on what West Elsdon Chicago HVAC design engineers do? This really is an exceptional trade with an an extensive listing of duties. An HVAC design engineer will be asked to get through several challenges to solve the actual issue. This task needs superior skill, proficieny, and the opportunity to manage time wisely.

Once an HVAC personel is licensed to function, they will join up with an engineering firm and start to functions on many heating, cooling, and refrigeration systems. Their responsibility would be to create new or replacement selections in line with their client’s requests. Each customer is going to have an exclusive set of wants whether or not it is related to developing codes or individual performance prospects. Making use of this information, the engineer sets off on a ride towards making something which is eco-friendly, energy-efficient and well suited for the place it’s likely to be placed in – (residential/commercial/industrial). They are usually in charge of the primary creations and overseeing the actual installation.

Generally speaking, an HVAC design engineer in West Elsdon Chicago will be seen working at a design company or maybe in a consulting firm according to their numerous years of expertise. Many engineers switch right into a consulting job because they get older and gain a better understanding of what’s required of them.

Comparing HVAC Engineer Versus HVAC Technician

HVAC Engineer and HVAC Technician are often mistaken for one another. Still, they have different tasks with regards to handling HVAC systems. It’s vital that you know the variance both as being a client also as a professional

An HVAC technician in West Elsdon Chicago is a more practical job, meaning they are usually seen going to a owner’s home to inspect their existing system. They often keep up with the installations, repairs, and over-all keep which is needed ever so often. Nearly all of their jobs are done together with the customer, meaning they should understand how to connect with people in the right way.

Having an HVAC engineer, they are accountable for creating a fresh HVAC system and ensuring that it fits just what a client is after. It needs to fit what the property owner needs whether or not it has to do with their setup, property, or everything of new system. Also, they are brought in to talk on HVAC designs to be certain things are in line with the latest standards. This is the reason they can end up hanging out in consulting assignments or at local engineering firms. This is the difference between those two vocation choices; HVAC Engineer vs HVAC Technician. There’s only so much you can save this page if you would like additional details on the HVAC Engineering services in West Elsdon Chicago, IL by New York Engineers we invite you to stop by at our blog.

Latest West Elsdon Chicago HVAC Engineering Related Article

Mechanical Engineers Design HVAC Systems for Sensitive Environments

HVAC Engineers Near Me

A well-designed HVAC system keeps temperature and moisture within a range that is considered comfortable for humans, while constantly renewing the air in a building and filtering out pollutants. Mechanical engineers are, in large part, responsible for ensuring that an HVAC system is operating as it should. The system must also provide an adequate airflow, since stagnant air and draftiness are both detrimental for performance.

In most residential and commercial settings, deviations from the ideal operating conditions are allowable if they are transitory, and there is generally a broad range of acceptable temperature and humidity values. However, there are sensitive environments such as healthcare facilities, where optimal conditions must be kept at all times. Many HVAC systems in less demanding environments are controlled based on temperature only, and humidity is controlled indirectly. However, sensitive environments require that each variable be monitored and controlled independently, and specialized high-performance filters may be required by codes.

Humidity Control in Sensitive Environments

Precise humidity control is typically required for environments with sensitive electronic equipment, healthcare facilities and other similar locations were human life or important systems are at stake. For example, the relative humidity levels for healthcare typically range from 40 to 60 percent:

  • Bacteria and viruses thrive with both low and high humidity levels.
  • Patients who suffer from asthma or allergic rhinitis also experience symptoms in response to humidity extremes.
  • Dry air absorbs moisture from mucous membranes, reducing the body’s ability to fight off infections.
  • Low humidity also increases static electricity accumulation, and discharges can damage modern medical equipment, which is important for medical procedures and generally expensive
  • Dust has a higher tendency to become airborne at low humidity levels, further increasing the chance of triggering allergic reactions.
  • High humidity creates the ideal conditions for mold and dust mites.

Depending on weather conditions, an HVAC system may be required to operate in humidification or drying mode at different times of the year. Some areas of a sensitive environment may have more stringent requirements than others; surgery rooms in hospitals are an example of this. It is the responsibility of qualified mechanical engineers to understand what is needed across various projects.

Air Dehumidification

There are two main approaches for controlling air humidity independently: the HVAC system can use cooling and heating coils in series, or a desiccant wheel can be deployed.

  • Cooling and heating coils: With this approach, air is cooled and dehumidified by the cooling coil until the desired relative humidity is reached. Since this normally results in overcooling, air then flows through a heating coil to raise its temperature back to an acceptable level. This way, both temperature and humidity requirements are met.
  • Desiccant wheel: This device captures air humidity downstream from the cooling coil, and releases it upstream for it to be condensed and gathered. At design conditions, this system does not require any heating input, although a preheating coil is added in case extra dehumidification is required.

Desiccant wheels typically save energy because they eliminate the need for overcooling and reheating. There may be exceptions, however, so it is important to assess each installation independently.

Air Humidification

Healthcare humidification systems are often based on steam, since heating water to high temperatures ensures the destruction of bacteria, especially Legionella. When steam is injected into an airstream, both humidification and heating are accomplished in the same step.

In the most sensitive environments, such as surgery rooms, steam-based humidification is normally required by law to ensure that the system is free from airborne bacteria. Adiabatic humidification is accepted in some sensitive applications, and it provides considerable savings compared with steam systems, although it is necessary to ensure it can be used legally.

Vapor Diffusion Retarders

Vapor diffusion retarders, also known as vapor barriers, complement air drying and humidification systems by providing a barrier against the diffusion of moisture through walls or other elements of the building envelope. Vapor diffusion retarders are classified into three main categories, depending on their rated permeance value:

  • Class I vapor barriers are rated for 0.1 perms or less. Some examples are glass, sheet metal and polyethylene.
  • Class II vapor barriers are rated for permeance values above 0.1 perms but less than or equal to 10 perms. Plywood and unfaced extruded polystyrene are two examples.
  • Class III vapor barriers have permeance values above 10 perms, and some examples are gypsum board, cellulose insulation, bricks and concrete blocks.

The specification of vapor barriers is strongly dependent on weather conditions, and can be especially challenging in northern states, due to how drastically temperature and relative humidity fluctuate throughout the year. Getting in touch with a qualified design firm is highly recommended.

Ventilation for Sensitive Environments: Air Changes per Hour and Filtering

Ventilation systems for sensitive environments must meet specific requirements in terms of air changes per hour (ACH). In surgery rooms, for example, the American Institute of Architects establishes 15 ACH, where 20% must be outdoor air.

  • In a surgery room with a floor area of 600 ft2 and a height of 10 ft, 15 ACH is equivalent to 90,000 ft3 per hour, or 1500 cfm. The outdoor air required would be 300 cfm to meet the 20% requirement.

Filters for sensitive applications must typically meet a minimum MERV rating, and in applications that are especially sensitive compliance with the HEPA standard may be required.

MERV Ratings

MERV stands for Minimum Efficiency Reporting Value, and it is a measurement scale for the effectiveness of filters, which was developed by ASHRAE in the 80s. The scale of MERV ratings ranges from 1 to 16, where larger numbers indicate that the filter is rated for smaller particles and has a higher average arrestance.

  • MERV 1-4: 60 to 80% arrestance, particles larger than 10.0 µm.
  • MERV 5-8: 80 to 95% arrestance, 3.0 to 10.0 µm.
  • MERV 9-12: 90 to 98% arrestance, 1.0 to 3.0 µm.
  • MERV 13-16: Over 95% arrestance, particles from 0.30 to 1.0 µm.

In healthcare applications, filters with MERV ratings of 7 or more are normally specified. In some applications, two filters in tandem are used, where the second has a higher MERV rating than the first.

HEPA Standard

HEPA stands for High-Efficiency Particulate Arrestance, and a filter must remove 99.97% of particles with a diameter of 0.3 µm to qualify as such. It is important to note that the term HEPA has been adopted to refer to any high-efficiency filter, but only those meeting the requirements set forth in the standard are real HEPA filters.

In healthcare applications, HEPA filters are widely used thanks to their ability to capture airborne bacteria and viruses. Once they have been trapped, high-power ultraviolet lights are used to kill them.

It is important to note that higher performance filters also involve an increased pressure drop, raising energy consumption. For this reason, it is important to select a filter with adequate performance for the application, but not over-specified.

General Recommendations from Mechanical Engineers for Sensitive Environment HVAC Design

The most important requirement for HVAC systems in sensitive environments is being able to control humidity and temperature simultaneously, while filtering out pollutants. Therefore, designs based on rules of thumb should be avoided:

  • Sizing air conditioning equipment in tons per square foot of floor area.
  • Sizing ventilation equipment in cfm per ton of HVAC capacity.

Instead, each system must be designed by mechanical engineers to meet a specific temperature and humidity range, as well as air changes per hour and percentage of outdoor air. Hiring the services of qualified engineering professionals is highly recommended to ensure that requirements are met.

searches related to HVAC Engineering in West Elsdon Chicago, IL.