Do not be confused by our NY-Engineers.Com is your best option if you are searching for Full Service Heating & Air Conditioning (HVAC) Engineering Firm in Chicago Illinois. We are not only an HVAC Firm in Chicago but also a leading provider of Sprinkler Design Engineering services in Gold Coast Chicago. Contact us at (+1) (312) 767.6877

Contact Us

As of late huge crowds have been stopping by our site looking for Construction Engineering in or near Chicago. This is due primarily due to the reputation we have built in this kind of work. Nevertheless, a lot of builders from Bannockburn to North Barrington, are not aware that New York Engineers is also a top contender for anyone searching for HVAC Company in Chicago, IL

The pursuit of energy-efficient buildings involves cost effective HVAC system design. This will include systems for architectural enclosure, domestic water heating, lighting, HVAC, and vertical transportation. The loads for the HVAC systems should come primarily from 5 different bases including lighting (cooling), your building envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load is a function of either the devices necessary in an attempt to introduce it in a space and control contaminant concentration or the number of persons who will occupy the area. In virtually all climates from the eastern and southwestern regions of america, to reduce outside air movement helps you to save energy whenever the outer air is either warm and humid or very cold.
Managing the ventilation rate will probably be determined by occupancy which is called a form of demand control ventilation. This can be a everyday sort of energy conservation plan that is utilized for spaces with intermittent or dense occupancy. Having heating and cooling loads dropped to a minimum can be accomplished by utilizing a high performance building envelope, occupancy sensors, and performance lighting that employs daylight response of lighting controls.

Chicago HVAC Engineers vs HVAC Technicians

When you’ve ever discussed the distinction between a HVAC Engineers versus HVAC Technicians, then continue reading:

Chicago HVAC engineers are definitely the folks that oversee installing of air cooling systems for residential and commercial buildings. They spend a lot of their work in offices doing higher-level supervision and preparation of installations nonetheless they do also stop by job sites every so often.

On the other hand, HVAC technicians usually do a lot of hands-on work  that deals with maintenance and repair. A HVAC technician may deal with an engineer to complete a number of the installation work, specifically for smaller jobs. Generally speaking HVAC techs do considerably more travel and may spend a lot of time identifying leaks, changing filters, doing recharges or decommissioning old and outdated systems that use old refrigerants.

HVAC engineers may have a chance to make more decisions about systems that are being used, and so they are the people who would offer advice about probably the most sensible refrigerants and which systems would be perfect for a larger building. In the industry, there is some competition between ‘the suits’ and ‘the ones that will get their hands dirty’, but the two jobs require a good understanding of how air conditioner is proven to work. In recent times huge crowds have been checking out the New York Engineers site looking for HVAC Convention Chicago 2019. However, the focus of our organization is to be the number one choice for anyone looking for a HVAC Chicago and or any of our other services including Construction Engineering Engineering services. Furthermore anyone looking for additional info about our Heating Cooling Air Conditioning Furnace (HVAC) Engineering Firm in Chicago Illinois takes a look at our blog…

New Blog Related to HVAC Chicago

An Electrical Engineer’s Guide to Circuit Breakers: Overview and Applications

Construction Engineering Degree

Circuit breakers are fundamental elements for a safe and code-compliant electrical installation. Conductors and electrical equipment are exposed to damage and malfunction, and there is always a risk that someone may connect a device incorrectly or use it for the wrong application. Electrical engineers see these issues frequently in their line of work. These conditions can cause a device to draw current above its rated value, and the corresponding circuit breaker trips to disconnect the fault.

Before providing an overview of circuit breakers, it is important to understand the difference between the two main current conditions that cause a circuit breaker to trip.

  • An overload current occurs when a device draws current above its rated value, but not by a drastic margin. For example, a motor that is rated at 60 Amperes but drawing 75 Amperes is likely suffering an overload condition.
  • A fault current is orders of magnitude higher than the rated current of a circuit, and it occurs when a live conductor touches another at a different voltage (short circuit), or a conductive surface (ground fault). There is a high-magnitude current in both cases, since low-resistance contact is established across a voltage difference. For example, a residential circuit normally carrying 20 Amperes may experience a few thousand Amperes during a fault.

A circuit breaker must trip under both conditions, but the ideal trip response is different for each case:

  • The response to an overload current should have a time delay. Some types of equipment draw current above their rated value for short periods of time as part of their normal operation. For example, electric motors draw an inrush current up to 8 times their rated current when they start.
  • The response to a fault current should be instantaneous. These currents are not normal under any operating conditions, and they must be cleared immediately when detected.

Given this combination of performance requirements, most circuit breakers actually have two protection mechanisms in a single device. There is a thermal protection mechanism that responds to overload current, and a magnetic protection mechanism that responds to fault currents.

Thermal and Magnetic Protection

The thermal protection mechanism in a circuit breaker is based on an expanding contact: the circuit is interrupted once the contact expands beyond a certain point. The circuit breaker is calibrated so that the contact will not open below rated current, but any current conditions exceeding it will eventually cause a trip. Since current is the heat source that expands the contact, more severe overload conditions cause a faster expansion and a shorter trip time.

The magnetic protection mechanism is based on induction. Current passes through a coil inside the circuit breaker, creating a magnetic field that opens the connection. The field is too weak to trip the breaker under normal operating conditions, but high-magnitude currents cause a strong magnetic field that forces the breaker open.

Main Types of Circuit Breakers, as Explained by Electrical Engineers

Most circuit breakers found in residential and commercial buildings are either miniature circuit breakers (MCB) or molded-case circuit breakers (MCCB). MCBs are more compact as implied by their name, but MCCBs are available in much higher current ratings and come with additional performance features. MCBs are normally available with a current rating of up to 100 amperes, while MCCBs reach up to 2,500 amperes.

You will probably not find MCCBs in small homes and businesses, according to many electrical engineers, but they are common in larger constructions, such as the high rise multi-family and office buildings found throughout larger cities.

Miniature Circuit Breakers

Miniature circuit breakers come in two main versions: DIN-rail mountable MCBs can be installed along with other protection and control devices that also use DIN rails, while plug-in MCBs are inserted on load centers with specially designed slots. Keep in mind that DIN-rail MCBs are designed for standard rails, while plug-in MCBs only fit into matching load centers from the same manufacturer.

Plug-in MCBs have one to three poles, depending on the number of live conductors in the circuit being protected. DIN-rail MCBs can have up to 4 poles, in order to disconnect the neutral conductor along with the live conductors. Regardless of the type of circuit breaker, it is important to select an adequate rated current and breaking capacity.

  • The rated current is determined by the circuit being protected. Any value above this eventually trips the thermal protection mechanism.
  • The breaking capacity is the largest fault current that the unit can interrupt without suffering permanent damage. Should a fault exceed this value, there is an ultimate breaking capacity where the breaker can still clear the fault but is permanently damaged. Any fault above the ultimate breaking capacity cannot be cleared by the circuit breaker, and must be handled by a higher capacity protection system connected upstream.

Miniature circuit breakers are also classified into three types based on their response to fault currents: Type B, C and D. The type determines the threshold where the magnetic protection takes over the thermal protection, causing an instantaneous trip.

Molded Case Circuit Breakers

MCCBs are bulkier than MCBs and are available with higher current ratings. Many models also feature adjustable trip settings, allowing a very accurate protection response if a specific load needs it.

Some MCCBs also come with a removable trip unit that can be replaced with a smaller capacity unit, to recondition the breaker for a load with reduced current. However, you cannot upgrade to a larger trip unit that exceeds the frame size of the MCCB.

There are modern MCCBs that do not use the conventional thermal-magnetic mechanism, but instead use an electronic circuit that measures current and simulates the trip response. This allows a very precise adjustment of protection settings.

Two subtypes of MCCB are designed specifically for the protection needs of electric motors: Motor protection circuit breakers (MPCB) and motor circuit protectors (MCP). The main difference is that an MPCB includes both thermal and magnetic protection, while an MCP only comes with magnetic protection and needs an external overload relay to offer full protection.

Conclusion

Electrical engineers must select the right type of circuit breaker, as it is very important to ensure the safe operation of building systems that include electrical components. Undersized breakers trip continuously and disrupt equipment operation, while oversized breakers do not provide reliable protection against overload current. If an overload is not interrupted, the heating effect can damage conductor insulation and eventually cause a ground fault or short circuit.