HVAC Groveland Park Chicago2018-11-19T07:43:17+00:00

HVAC Groveland Park Chicago | Expert Power Efficient System Designs

Electrical Engineering Schools
Contact Us!

Don’t be confused by our NY Engineers is the top choice if you need a Full Service Heating and Air Conditioning (HVAC) Engineering Firm in Chicago Illinois. We are not only an HVAC Company in or near Chicago but also a leading provider of Electrical Engineering Engineering services throughout Groveland Park Chicago. Call (312) 767-6877

Contact Us!

Lately Many people have been visiting our site in search of Architectural Engineering in or near Chicago. That is due primarily due to the following we have develop in this kind of work. Nevertheless, many builders from Broadview to Zion, Illinois, do not know that New York Engineers is also the ideal choice for anyone looking for HVAC Company in or near Chicago

The search for energy-efficient buildings involves energy efficient HVAC system design. This can include systems for lighting, architectural enclosure, domestic water heating, HVAC, and vertical transportation. The loads for your HVAC systems can come primarily from five different sources including lighting (cooling), the property envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load might be a purpose of either the instruments needed in an attempt to introduce it in a space and control contaminant concentration or the amount of people that will be in the room. In the majority of climates in the southwestern and eastern parts of america, to lower outter air flow helps save energy whenever the

outside air is either humid and warm or very cold.
Manipulating the ventilation rate is going to be dependant on occupancy which is referred to as a variety of demand control ventilation. This really is a common type of energy conservation tatic which is used for buildings with occasional or crowded occupancy. Having heating and cooling loads dropped to a minimum can be achieved by using a very high performance building envelope, occupancy sensors, and high performance lighting that utilize daylight response of lighting controls.

Chicago HVAC Engineering services vs HVAC Techs

When you’ve ever discussed the difference between a HVAC Technician versus HVAC Engineers, then please read on:

HVAC engineers are the individuals who oversee the installation of air conditioner systems for both residential and commercial buildings. They spend a great deal of their day in offices doing more impressive range organization and arranging of installations nevertheless they do also visit job sites every so often.

On the other hand, HVAC technicians tend to do a lot of hands-on work  that deals with repair and maintenance. A HVAC technician may work with or for an engineer to complete several of the installation task, especially on smaller jobs. In general HVAC technicians do considerably more travel and may spend considerable time changing filters, identifying leaks, doing recharges or decommissioning old and outdated systems which use old refrigerants.

HVAC engineers could have the ability to make more decisions about systems that are used, plus they would be the folks that would offer assistance with the most sensible refrigerants and which systems would work best with a bigger building. In the industry, there exists some competition between ‘the suits’ and ‘the ones which get their hands dirty’, but the two jobs do require a great familiarity with how air cooling is proven to work. As of late a lot of individuals have been checking out our sites searching for things like Best HVAC Chicago. Nevertheless, the goal of our firm is to be the number one choice for anyone looking for a HVAC Chicago and or any of our other services including Sprinkler System Engineering services. Furthermore anybody looking for more information about our Heating Cooling Air Conditioning Furnace (HVAC) Engineering Firm in Chicago Illinois stops by at our blog!

Recent Article Related to HVAC Chicago

Value Engineering: The Effective Use of Daylighting in Buildings

Architectural Engineers

Daylight has two key advantages over artificial lighting. In the first place, daylighting reduces electricity bills because it is available for free. The effective use of lighting is essential in many value engineering projects. In addition, it offers perfect color rendering performance, allowing the colors and textures of objects to be appreciated without visual distortion. No artificial light source can offer this combination of benefits:

  • Incandescent and halogen lighting matches the color performance of daylight, but both types of lighting are inefficient and expensive to operate. Another disadvantage of incandescent and halogen bulbs is their short service life, typically under 1,000 hours of use, which means replacements are needed frequently.
  • LED fixtures offer a very low operating cost, but many products do so at the expense of color performance. Some of the latest LED lamps are designed to replicate the warm and natural color output of incandescent lighting, but this generally comes with a higher price tag.

LED lighting is a high-performance technology, offering significant energy and maintenance savings throughout its service life, but daylight is always the winning option when available. This option simply increases the value engineering of your project. However, there are three important factors to consider for effective daylighting implementation:

  • The sun has a heating effect, and a successful daylighting design must minimize it while still allowing sunlight to enter the building. If solar heating is not controlled it can raise air conditioning loads significantly, negating part of the potential savings.
  • Sunlight is unavailable during nighttime and limited during cloudy days, so the building must be equipped with controls that adjust artificial lighting in response to this. Also, controls ensure that savings are achieved when natural lighting is enough, by dimming or turning off indoor fixtures.
  • Daylighting design must ensure that the sun is not directly visible for occupants, since the resulting glare is unbearable. The same applies for shiny surfaces that can reflect the sun, which cause glare as well.

Daylighting is highly recommended in commercial buildings, contributing positively to employee motivation and productivity, and addition to providing energy savings.

Optimizing Window Orientation for Daylighting in High-Value Engineering Projects

Windows play a very important role in any daylighting design, since they should be placed so that natural light can enter the building, but at the same time heating and glare must be prevented. In general, windows in the north and south faces of a building perform much better than those facing east or west.

In some areas of the northern hemisphere, most of the sunshine available throughout the year comes from the southern portion of the sky. Therefore, south-facing windows are the ones that get the most daylight, with minimal glare and heating because the sun’s elevation above the horizon is high and most sunshine is received at a sharp angle. The sun is at a lower altitude in the winter, increasing the heating effect, but this is beneficial because the total heating load is reduced.

However, it may be necessary to control glare with shades. North-facing windows are also effective for daylighting because most of the sunshine they get throughout the year is indirect, which means glare and heating are minimized.

East-facing windows receive direct sunshine during the morning, and the same happens with west-facing windows in the afternoon. For effective daylighting, the number of windows facing east or west should be minimized, and ample use of shading is often necessary to prevent glare and excessive heating. In low-rise construction, it is often possible to use trees for additional shading. If the surrounding buildings are taller, they also block direct sunlight effectively.

Glare should be prevented under all circumstances: slight glare is distracting and uncomfortable, and severe glare severely limits visibility and can damage the eyes. Heating is welcome in the winter, but drastically increases air conditioning loads during the summer. To achieve the best results with daylighting, window area should be maximized in the north and south faces of a building and minimized for the east and west sides.

Skylights and High-Efficiency Windows

Skylights and high-efficiency windows are the two most common types of daylighting products for buildings. Both are designed to maximize lighting while keeping the heating effect under control.

Skylights

Skylights allow buildings to capture heat through the roof, and their geometry is designed to minimize heat transfer into the building. Skylights have the highest potential in low-rise constructions with a large rooftop area, where it is often possible to turn off the artificial lighting system completely. Warehouses, industrial plants and shopping malls are some example of buildings where skylights have a high potential.

Solar panels are a great compliment for skylights, since they can be used to fill the gaps between them, making sure that all the sunlight incident on the rooftop is used. The sunshine that is not used for natural lighting is converted to electricity and used to power other appliances, which can include artificial lighting.

The potential uses of skylights in high-rise construction are more limited, since the rooftop area is small compared with the total indoor area, and only the upper levels can benefit from the concept.

High-Efficiency Windows

There are now fenestration products that are designed to allow sunlight through while blocking off a significant portion of the heat, and they can be effective in daylighting designs. For example, double-pane windows use two sheets of glass with a gap between them to minimize heat conduction. The gap may be vacuumed or filled with an inert gas for improved results. Some windows also use photochromic glass, which is normally transparent but becomes more opaque in response to the amount of incident light.

A window’s ability to block heat is specified by its Solar Heat Gain Coefficient (SHGC), which is a ratio of heat transmitted to heat received. For example, a high-efficiency window with a SHGC of 0.50 blocks half of all solar heat, while letting most of the light through.

Indoor Lighting Automation to Complement Daylighting

The main limitation of daylight is that availability depends on the time of the day and local weather. The building still needs an artificial lighting system, with the difference that it can be turned off or set to operate at partial output when natural light is available. Daylight harvesting consists on keeping lighting levels constant regardless of the amount of natural lighting available:

  • If natural lighting can provide 100% of the illuminance level, lighting fixtures are turned off.
  • As the availability of natural lighting decreases, the output of artificial lighting is controlled with dimmers to compensate for the gap.
  • During nighttime, lighting requirements are met fully with artificial lighting.

It is important to note that daylighting only provides savings if the artificial lighting system is dimmed or turned off in response to natural lighting levels. If lighting fixtures are left on all day long at full brightness, indoor environments are illuminated more than necessary and the potential savings are negated. In fact, energy consumption may increase because the air conditioning system must remove heat from two sources simultaneously – artificial lighting and the sun.

Controlling Glare in Daylighting Design

Glare issues can arise in poorly-designed daylighting systems, and it is important to distinguish between the two main types of glare:

  • Discomfort glare is unbearable and causes an instinctive reaction to close the eyes and look away. This is the type of glare you feel if you look at the sun directly by accident.
  • Disability glare limits vision but does not cause the drastic reaction of discomfort glare. An example of disability glare is when a bright object gets reflected on your computer screen and makes reading difficult.

Adequate window orientation not only limits heat gain, it also controls glare. By minimizing the number of windows facing east and west and using adequate shading, glare is reduced significantly. Interior design also plays an important role in keeping glare under control. Any surfaces or objects that can reflect sunlight directly should be avoided, especially if they reflect lights towards occupied areas.

Concluding Remarks

Daylighting can reduce electricity bills significantly while helping create indoor environments that feel natural and inviting. This invites a higher value engineering than buildings without daylighting. However, professional design services are highly recommended before attempting any daylighting project, or otherwise there may be issues with glare or excessive solar heating.

Searches Related to HVAC Chicago