HVAC Stony Island Park Chicago 2018-12-02T18:28:40+00:00

HVAC Stony Island Park Chicago | Expert Energy Efficient System Designs

HVAC Engineering Salary
Contact Us

Do not be misled by our NY-Engineers.Com is your best bet if you are looking for Full Service Heating & Air Conditioning (HVAC) Engineering Firm in Chicago Illinois. We’re not only an HVAC Chicago but also a leading provider of MEP Engineering Engineering services throughout Stony Island Park Chicago. Call (312) 767.6877

Contact Us

Lately Hundreds of people have been visiting the NY Engineers website in search of Construction Engineering in or near Chicago. That is due because of the reputation we have develop in this kind of work. With that said, many general contractors from Lynwood to Northfield, do not know that NY Engineers is also a top choice for anyone looking for HVAC Company in Chicago, IL.

The quest for cost effective buildings involves energy-efficient HVAC system design. This will include systems for architectural enclosure, domestic water heating, lighting, HVAC, and vertical transportation. The loads for your HVAC systems may come primarily from five different bases including lighting (cooling), the construction envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load will be a purpose of either the mechanisms necessary in order to introduce it right into a space and control contaminant concentration or the amount of individuals that will occupy the area. In the vast majority of climates from the southwestern and eastern regions of america, to minimize outter ventilation helps save energy whenever the outer air is either humid and warm or very cold.
Managing the ventilation rate will likely be dependant on occupancy which is referred to as a form of demand control ventilation. It is a common type of energy conservation approach that is utilized for homes with intermittent or dense occupancy. Having heating and cooling loads reduced as low as possible can be carried out by using a very high performance building envelope, occupancy sensors, and performance lighting that apply daylight response of lighting controls.

Chicago HVAC Engineering services vs HVAC Techs

When you’ve ever considered the difference between a HVAC Technician versus HVAC Engineers, then keep reading:

Chicago HVAC engineers would be the folks that manage the installation of air conditioning systems for commercial and residential buildings. They spend plenty of their time in offices doing higher-level organization and planning of installations nonetheless they do also see job sites every so often.

On the other hand, HVAC technicians have a tendency to do a lot of hands-on work with repair and maintenance. A HVAC technician may assist an engineer to accomplish a number of the installation task, specifically on smaller jobs. Generally HVAC techs do a lot more travel and could spend considerable time changing filters, identifying leaks, doing recharges or decommissioning old and outdated systems that utilize old refrigerants.

HVAC engineers might have the ability to make more decisions about systems that are employed, plus they would be the people that would offer assistance with one of the most sensible refrigerants and which systems would work best with a greater building. In the trade, there is some conflict between ‘the suits’ and ‘the ones which get their hands dirty’, but the two jobs require a great expertise in how air cooling does work. As of late a lot of individuals have been crawling our website looking for HVAC in Chicago. With that said, the focus of our organization is to become the top option for anyone seeking a HVAC Contractor in Chicago and or any of our other services including Protection Engineering services. Furthermore anyone searching for additional info about our Heating & Air Conditioning (HVAC) Engineering Firm in Chicago Illinois stops by at our Utility Filings blog.

Recent Blog Article Related to HVAC Contractor in or near Chicago

An HVAC Engineering Professional Explains Types of Compressors Used in Chillers

Fire Protection Engineering Magazine

The compressor performs a fundamental role in the operation of a chiller, making it possible to remove heat from indoor spaces or from industrial processes via HVAC engineering. Once the refrigerant in a chiller absorbs the heat from a building or process it becomes a gas, but it is incapable of releasing the heat right away in this form. However, after the compressor raises the pressure and temperature of the gasified refrigerant, the heat can be expelled. Air-cooled chillers release heat directly outdoors, while water-cooled chillers release it into a stream of water that is then pumped to a cooling tower.

There are many types of compressors, each with advantages and disadvantages. This article will provide an overview of the three types most commonly used in large commercial chillers. HVAC engineers can determine the best option for your building based on load characteristics.

  • Reciprocating compressor
  • Centrifugal compressor
  • Rotary-screw compressor

In commercial space cooling systems, the compressor is typically the component with the highest electricity consumption. Therefore, it is important to have a well-sized unit, and of a type that is suitable for the application at hand.

Reciprocating Compressors

The reciprocating compressor has a shape similar to that of a car engine cylinder, and it is also known as piston compressor for this reason. Refrigerant that has evaporated after absorbing heat is fed into the cylinder through suction valves, and compressed by the piston before being sent to the condenser.

For a given cooling capacity, reciprocating compressors have a lower upfront cost than centrifugal and rotary-screw compressors in HVAC engineering. They also offer design flexibility, allowing multiple units to be installed together to serve variable cooling loads – individual units are activated or deactivated as needed.

The main limitations of reciprocating compressors are their lower energy efficiency and their demanding maintenance, compared with other types of compressors. Also, although these compressors can achieve good capacity control when multiple units are used, there are few options to modulate the capacity of an individual unit. The two most common options are:

  • ON/OFF Control: Operating the unit intermittently (reduced duty cycle) when its full capacity is not required.
  • Cylinder Unloading: The compressor cylinder can be equipped with additional suction valves or a clearance valve. These valves remain closed when the unit operates at 100% capacity, but may be opened in several combinations to achieve reduced capacity.

Centrifugal Compressors

If a reciprocating compressor can be compared to a car engine, this type is comparable to a water pump because it also uses an impeller, with the difference that it operates with refrigerant. These compressors are also available in hermetic and open models, where the open construction offers higher efficiency.

At rated load, centrifugal compressors are more efficient than both reciprocating and rotary-screw compressors. They also offer a compact construction and are available in a wide range of cooling capacities. Capacity control is normally achieved with inlet vanes that increase or decrease the flow of refrigerant into the impeller.

Despite their superior efficiency at full load, centrifugal compressors suffer from a drastic loss of efficiency at part-load. At very low cooling loads they are rendered unable to operate, due to a phenomenon called surging: refrigerant that is already compressed flows back into the impeller, disrupting its operation.

Centrifugal compressors have the least number of moving parts among the three main compressor types, which means there are less components to service.

However, in most cases the impeller must be factory-ordered if fails; suppliers rarely keep stock because it’s a highly specialized component. Balancing and vibration must also be checked frequently to avoid loss of performance and premature component failure.

Rotary-Screw Compressors

This type of compressor uses two helical screws that are designed to mesh with one another seamlessly while rotating at high speed. They are manufactured with high precision to create a clearance between them, which serves as the compression chamber. These compressors are available in hermetic and open versions like the two previous types described, and capacity control is achieved with a special valve that varies the internal volume ratio.

Although centrifugal compressors are more efficient at full load, rotary-screw compressors offer the best performance during part-load operation. Since the cooling load on a building varies throughout the year, rotary-screw compressors tend to achieve the lowest operating cost overall, even if centrifugal compressors are more efficient at full load.

The main limiting factor of rotary-screw compressors is their high price. If the application does not provide opportunities to take advantage of their capacity control and their superior part-load efficiency, another type of compressor can be considered.

HVAC Engineering: Choosing the right Compressors

High-rise commercial buildings, like those found in many major cities, can generally achieve the best results with a space cooling chiller that uses a rotary-screw compressor. Despite being the most expensive option, it offers the best performance under the variable cooling load that characterizes buildings, while being the simplest system to service – consider that maintenance activities can be quite disruptive in a busy commercial property.

Working with qualified HVAC engineering experts ensures that your property gets a space cooling system that delivers high performance at an optimal energy cost. Chiller selection is a key element, but it is also important to specify adequate complementary systems: air handling units, hydronic piping, cooling towers, HVAC controls, etc.