HVAC Vittum Park Chicago2018-11-27T00:15:53+00:00

HVAC Vittum Park Chicago | Expert Power Efficient System Designs

Architectural Engineers
Contact Us

Do not be misled by the name NY-Engineers.Com is your best option if you need a Full Service Air Conditioning, Heating & Cooling (HVAC) Engineering Firm in Chicago Illinois. We are not only an HVAC Chicago but also a leading provider of Sprinkler System Engineering services in or near Vittum Park Chicago. Call us at (312) 767.6877

Contact Us

In recent times Hundreds of individuals have been visiting the NY Engineers website searching for MEP Engineering in or near Chicago. This is due primarily due to the following we have develop in this types of projects. However, many general contractors from Countryside to Old Mill Creek, don’t know that New York Engineers is also the ideal choice for anyone looking for HVAC Chicago, IL

The pursuit of energy-efficient buildings involves power efficient HVAC system design. This can include systems for architectural enclosure, domestic water heating, lighting, HVAC, and vertical transportation. The loads for your HVAC systems can come primarily from 5 different bases including lighting (cooling), your building envelope (cooling and heating), ventilation (cooling and heating), equipment for program use (cooling) and occupancy (cooling).
The ventilation load will be a function of either the machines needed in an attempt to introduce it in a space and control contaminant concentration or the amount of people that will occupy the space. In virtually all climates in the southwestern and eastern regions of the united states, to minimize outter ventilation can save energy whenever the exterior air is either warm and humid or very cold.
Manipulating the ventilation rate will be determined by occupancy which is called a variety of demand control ventilation. This can be a everyday sort of energy conservation plan that is used for homes with irregular or heavy occupancy. Having cooling and heating loads dropped to a minimum can be accomplished by making use of a high performance building envelope, occupancy sensors, and performance lighting that apply daylight response of lighting controls.

Chicago HVAC Engineers versus HVAC Technicians

When you have ever thought about the distinction between a HVAC Engineers versus HVAC Technicians, then keep reading:

Chicago HVAC engineers would be the folks that watch over the installation of air conditioner systems for both commercial and residential buildings. They spend lots of their time in offices doing more impressive range supervision and arranging of installations nonetheless they do also visit job sites every now and then.

On the other hand, HVAC technicians tend to do a lot of the hands-on work with maintenance and repair. A HVAC tech may work with or for an engineer to accomplish several of the installation task, particularly for smaller jobs. On the whole HVAC techs do considerably more travel and might spend a lot of time identifying leaks, changing filters, doing recharges or getting rid of old and outdated systems that utilize old refrigerants.

HVAC engineers could possibly have the opportunity to make more decisions about systems that are used, and they also are definitely the individuals who would offer advice about one of the most sensible refrigerants and which systems would be perfect for a much bigger building. In the industry, there may be some conflict between ‘the suits’ and ‘the ones which get their hands dirty’, but the two jobs require a good knowledge of how air-con works. Nowadays huge crowds have been getting to the NY Engineers website searching for things like HVAC Companies Chicago. Nevertheless, the focus of our organization is to be the to go to company for those searching for a HVAC Chicago and or any of our other services including Electrical Engineering Engineering services. We ask that those looking for more info about our Air Conditioning, Heating & Cooling (HVAC) Engineering Firm in Chicago Illinois visits at our blog!

New Blog Related to HVAC Contractor near Chicago

An Electrical Engineer’s Guide to Circuit Breakers: Overview and Applications

HVAC Engineer Vacancies

Circuit breakers are fundamental elements for a safe and code-compliant electrical installation. Conductors and electrical equipment are exposed to damage and malfunction, and there is always a risk that someone may connect a device incorrectly or use it for the wrong application. Electrical engineers see these issues frequently in their line of work. These conditions can cause a device to draw current above its rated value, and the corresponding circuit breaker trips to disconnect the fault.

Before providing an overview of circuit breakers, it is important to understand the difference between the two main current conditions that cause a circuit breaker to trip.

  • An overload current occurs when a device draws current above its rated value, but not by a drastic margin. For example, a motor that is rated at 60 Amperes but drawing 75 Amperes is likely suffering an overload condition.
  • A fault current is orders of magnitude higher than the rated current of a circuit, and it occurs when a live conductor touches another at a different voltage (short circuit), or a conductive surface (ground fault). There is a high-magnitude current in both cases, since low-resistance contact is established across a voltage difference. For example, a residential circuit normally carrying 20 Amperes may experience a few thousand Amperes during a fault.

A circuit breaker must trip under both conditions, but the ideal trip response is different for each case:

  • The response to an overload current should have a time delay. Some types of equipment draw current above their rated value for short periods of time as part of their normal operation. For example, electric motors draw an inrush current up to 8 times their rated current when they start.
  • The response to a fault current should be instantaneous. These currents are not normal under any operating conditions, and they must be cleared immediately when detected.

Given this combination of performance requirements, most circuit breakers actually have two protection mechanisms in a single device. There is a thermal protection mechanism that responds to overload current, and a magnetic protection mechanism that responds to fault currents.

Thermal and Magnetic Protection

The thermal protection mechanism in a circuit breaker is based on an expanding contact: the circuit is interrupted once the contact expands beyond a certain point. The circuit breaker is calibrated so that the contact will not open below rated current, but any current conditions exceeding it will eventually cause a trip. Since current is the heat source that expands the contact, more severe overload conditions cause a faster expansion and a shorter trip time.

The magnetic protection mechanism is based on induction. Current passes through a coil inside the circuit breaker, creating a magnetic field that opens the connection. The field is too weak to trip the breaker under normal operating conditions, but high-magnitude currents cause a strong magnetic field that forces the breaker open.

Main Types of Circuit Breakers, as Explained by Electrical Engineers

Most circuit breakers found in residential and commercial buildings are either miniature circuit breakers (MCB) or molded-case circuit breakers (MCCB). MCBs are more compact as implied by their name, but MCCBs are available in much higher current ratings and come with additional performance features. MCBs are normally available with a current rating of up to 100 amperes, while MCCBs reach up to 2,500 amperes.

You will probably not find MCCBs in small homes and businesses, according to many electrical engineers, but they are common in larger constructions, such as the high rise multi-family and office buildings found throughout larger cities.

Miniature Circuit Breakers

Miniature circuit breakers come in two main versions: DIN-rail mountable MCBs can be installed along with other protection and control devices that also use DIN rails, while plug-in MCBs are inserted on load centers with specially designed slots. Keep in mind that DIN-rail MCBs are designed for standard rails, while plug-in MCBs only fit into matching load centers from the same manufacturer.

Plug-in MCBs have one to three poles, depending on the number of live conductors in the circuit being protected. DIN-rail MCBs can have up to 4 poles, in order to disconnect the neutral conductor along with the live conductors. Regardless of the type of circuit breaker, it is important to select an adequate rated current and breaking capacity.

  • The rated current is determined by the circuit being protected. Any value above this eventually trips the thermal protection mechanism.
  • The breaking capacity is the largest fault current that the unit can interrupt without suffering permanent damage. Should a fault exceed this value, there is an ultimate breaking capacity where the breaker can still clear the fault but is permanently damaged. Any fault above the ultimate breaking capacity cannot be cleared by the circuit breaker, and must be handled by a higher capacity protection system connected upstream.

Miniature circuit breakers are also classified into three types based on their response to fault currents: Type B, C and D. The type determines the threshold where the magnetic protection takes over the thermal protection, causing an instantaneous trip.

Molded Case Circuit Breakers

MCCBs are bulkier than MCBs and are available with higher current ratings. Many models also feature adjustable trip settings, allowing a very accurate protection response if a specific load needs it.

Some MCCBs also come with a removable trip unit that can be replaced with a smaller capacity unit, to recondition the breaker for a load with reduced current. However, you cannot upgrade to a larger trip unit that exceeds the frame size of the MCCB.

There are modern MCCBs that do not use the conventional thermal-magnetic mechanism, but instead use an electronic circuit that measures current and simulates the trip response. This allows a very precise adjustment of protection settings.

Two subtypes of MCCB are designed specifically for the protection needs of electric motors: Motor protection circuit breakers (MPCB) and motor circuit protectors (MCP). The main difference is that an MPCB includes both thermal and magnetic protection, while an MCP only comes with magnetic protection and needs an external overload relay to offer full protection.

Conclusion

Electrical engineers must select the right type of circuit breaker, as it is very important to ensure the safe operation of building systems that include electrical components. Undersized breakers trip continuously and disrupt equipment operation, while oversized breakers do not provide reliable protection against overload current. If an overload is not interrupted, the heating effect can damage conductor insulation and eventually cause a ground fault or short circuit.